During the operation of high-energy proton accelerators, the air in the tunnel is activated with the production of radionuclides. For CSNS (China Spallation Neutron Source), the first pulsed neutron source in China for multidisciplinary research, an online air activation monitoring system was developed to evaluate the radiation safety of the staff and the public, which consisted of a NaI detector, Pb shielding, an MB container and a control system. With the monitoring system, gamma spectra of the activated air from controlled areas are measured, and the activity concentration and immersion dose rates of radionuclides in air are calculated and displayed in real time.

View Article and Find Full Text PDF

The China Spallation Neutron Source (CSNS) is the first pulsed neutron source in China for multidisciplinary research. After operation with 80 kW proton beam for 4 months, 3 circuits of target station coolant, light water 1/2/3 were sampled, and radionuclides in coolants were measured. The results showed that, activity concentration of H-3 in coolant can be up to the magnitude of 1.

View Article and Find Full Text PDF

The back-n project in China Spallation Neutron Source (CSNS) was launched primarily for nuclear data measurements. In the backscattering neutron hall, the neutron and gamma monitors were used for dose monitoring. Because of the dead time problem of monitors, performance of the monitors in such pulsed radiation field needs to be analyzed.