Purpose: The research investigates the occupational eye lens dose of interventional cardiologists and examines several methodologies for measuring eye lens doses, including direct methods using Hp(3) dosimeters and indirect methods using surrogate dosimeters. Moreover, the study scrutinizes factors impacting the evaluation of eye lens dose, making a substantial contribution to the field within Sri Lanka.
Methodology: Twelve interventional cardiologists underwent monitoring for eye lens doses utilizing both direct (Hp(3)) and indirect (Hp(10) and Hp(0.
Technological differences between computed radiography (CR) and digital radiography (DR) systems can influence patient doses and exposure parameters in pelvic x-ray examinations. The presence of radiosensitive organs in the pelvic region underscores the need to optimize these parameters for both CR and DR systems. This prospective study aimed to compare the patient doses and exposure parameters for adult patients undergoing pelvic x-ray examinations using CR and DR systems, based on data from Sri Lanka.
View Article and Find Full Text PDFEnsuring the safety of healthcare workers in interventional cardiology necessitates effective monitoring of occupational radiation exposure. This study aims to assess the accuracy of the over-apron single dosimetric approach compared with double dosimetric methods and explore the relationship between under-apron and over-apron doses. This investigation showed that the prescribed annual dose constraint of 20 mSv year-1 was not exceeded by the maximum annual occupational doses determined by dosimetric algorithms, which were 0.
View Article and Find Full Text PDFDiagnostic reference levels (DRLs) and achievable doses (ADs) provide guidance to optimise radiation doses for patients undergoing medical imaging procedures. This multi-centre study aimed to compare institutional DRLs (IDRLs) across hospitals, propose ADs and multi-centric DRLs (MCDRLs) for four common x-ray examinations in Sri Lanka, and assess the potential for dose reduction. A prospective cross-sectional study of 894 adult patients referred for abdomen anteroposterior (AP), kidney-ureter-bladder (KUB) AP, lumbar spine AP, and lumbar spine lateral (LAT) x-ray examinations was conducted.
View Article and Find Full Text PDFInterventional cardiologists face significant radiation exposure during interventional cardiology procedures. Therefore, this study focuses on assessing radiation exposure among interventional cardiologists during their procedures. Specifically, it aims to determine the effectiveness of both single and double dosimeter methods in estimating annual occupational radiation doses.
View Article and Find Full Text PDFThe establishment of diagnostic reference levels (DRLs) is an effective tool for optimising radiation doses delivered to patients during medical imaging procedures. This study aimed to compare the institutional DRLs (IDRLs) and propose a multi-centric diagnostic reference level (MCDRL) for chest x-ray examinations in adult patients in Sri Lanka. A prospective cross-sectional study was conducted with 1091 adult patients across six major tertiary care hospitals.
View Article and Find Full Text PDFThe present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X-ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma-area product (KAP) of adult patients undergoing routine projection X-ray examinations.
View Article and Find Full Text PDFPurpose: To investigate the current status of radiation treatment facilities in Sri Lanka and to explore future possibilities required to adequately address increasing cancer care.
Methods: Hospitals with radiation therapy facilities from across the country were identified. Data pertaining to the types of radiotherapy equipment, radiation oncology staffing, and radiotherapy education were collected by onsite visit, conversation over the phone, and from other available cancer resources in Sri Lanka.
The increased use of medical imaging and radiation therapies has resulted in a high demand for medical physicists. Although medical physics programmes are well established in advanced countries, the same cannot be said for many low- and medium-income countries. In some countries, there may be huge variations in the graduates' skill and quality, which pose a problem in ensuring patient safety, providing quality assurance in treatments, optimisation of protocols and standardisation of quality.
View Article and Find Full Text PDFWe propose a simple and efficient method to measure beam attenuation in one or two dimensions using an amorphous silicon electronic portal imaging device (a-Si EPID). The proposed method was validated against ionization chamber measurements. Beam attenuation through treatment couches (Varian Medical Systems) and immobilization devices (CIVCO Radiotherapy, USA) was examined.
View Article and Find Full Text PDFThe fluorescence spectra of Bacillus spores are measured at excitation wavelengths of 280, 310, 340, 370, and 400 nm. When cluster analysis is used with the principal-component analysis, the Bacillus globigii spores can be distinguished from the other species of Bacillus spores (B. cereus, B.
View Article and Find Full Text PDFFluorescence spectroscopy has been used to measure fluorescence quantum efficiency (QE) of dried Bacillus spores (washed and unwashed) fixed to a quartz substrate. Fluorescence spectra and QE of anthracene in ethanol was used as the standard. We measured the absorption and fluorescence signal of the spores as a function of the number of spores.
View Article and Find Full Text PDFDipicolinic acid (DPA) and the Ca2+ complex of DPA (CaDPA) are major chemical components of bacterial spores. With fluorescence being considered for the detection and identification of spores, it is important to understand the optical properties of the major components of the spores. We report in some detail on the room-temperature fluorescence excitation and emission spectra of DPA and its calcium ion complex and provide a comparison of the excitation-emission spectrum in a dry, wet paste and aqueous form.
View Article and Find Full Text PDF