The paper considers the state of Russian electrographic technology in Russia and gives examples of its electrocardiographic apparatuses, among which there are electrocardiographs in common use and cardiac complexes that have extended functional capacities.
View Article and Find Full Text PDFThe paper deals with the functional diagnosis based on the synchronous analysis of a spirogram and a cardiac intervalogram (CIG) by evaluating respiratory sinus arrhythmia (RSA). A method based on the calculation of R-R interval differences in separate breathing cycles is used for automated reckoning of RSA. A band-pass filter is employed to separate out a respiratory constituent of CIG.
View Article and Find Full Text PDFThe basic constructive and algorigthmic designs which are widely used in the up-to-date national computers to measure forced expiration parameters are analysed. The most frequently encountered circuits and basic metrological parameters are given and testing procedures are outlined.
View Article and Find Full Text PDFThe author reviews the current methods and facilities used for measuring ventilatory pulmonary function. Makes conclusions about prospective methods of the setting of standards and checking of the metrological characteristics as well as about the structure of the necessary equipment.
View Article and Find Full Text PDFA method that may be used for identifying the dynamic characteristics of the measuring canal of a device for studying the respiratory parameters is described. The device is equipped with a flow-metering primary transducer of variable pressure differential and a semiconductor pressure transformer of the PDP-10 or PDP-12 types according to the reaction towards graded action. The results of the computation of dynamic errors that may occur in measuring the main parameters of forced expiration by devices of such design are analyzed.
View Article and Find Full Text PDFTo correlate the dynamic characteristics of the units used to measure forced expiration to the dynamic errors of the same parameters measurements, the mathematical model of the process was worked out. This is the measuring pattern based on the description of the unit by the second-order differential equation with constant coefficients. The diagrams of the obtained dependences are stated.
View Article and Find Full Text PDFModern methods for the evaluation of principal respiration indexes were analysed to formulate the demands for methodological characteristics of the devices used in lung functional diagnosis. As a result the extent of measurement random errors of main respiration indexes, which guarantee the prescribed level of right diagnosis probability are established.
View Article and Find Full Text PDFThe pneumotachograph with a velocity head flowmeter and a linearization system has been studied. Theoretical and experimental results have revealed a possibility to design a multilevel pneumotachograph with the Pito tube providing gas output measurements at a wide respiration range while the slight flow resistance and the small dead space being maintained. It also allows for undisturbed data recording.