Background: Bloodstream infections (BSIs) are a life-threatening acute medical condition and current diagnostics for BSIs suffer from long turnaround time (TAT). Here we show the validation of a rapid detection-analysis platform (RDAP) for the diagnosis of BSIs performed on clinical blood samples METHODS: The validation was performed on a cohort of 59 clinical blood samples, including positive culture samples, which indicated confirmed bloodstream infections, and negative culture samples. The bacteria in the positive culture samples included Gram-positive and Gram-negative pathogenic species.
View Article and Find Full Text PDFBackground: The detection of minute amounts of protein biomarkers in body fluids is believed to provide early diagnosis and prognosis of mild traumatic brain injury (mTBI). An ultrasensitive detection method was used to detect S100B, the most studied potential marker for the diagnosis of mTBI.
Methods: The detection method was a modified electrochemical immunoassay technique that provides voltage controlled intrinsic current signal amplification.
The current culture-based approach for the diagnosis of bloodstreams infection is incommensurate with timely treatment and curbing the prevalence of multi-drug resistant organisms (MDROs) due to its long time-to-result. Bloodstream infections typically involve extremely low (e.g.
View Article and Find Full Text PDFA modified immunosensing system with voltage-controlled signal amplification was used to detect Shigella in stool and blood matrixes at the single-digit CFU level. Inactivated Shigella was spiked in these matrixes and detected directly. The detection was completed in 78 min.
View Article and Find Full Text PDFThe global demand for ethanol as an alternative fuel continues to rise. Advancement in all aspects of ethanol production is deemed beneficial to the ethanol industry. Traditional fermentation requires 50-70 hours to produce the maximum ethanol concentration of 7-8% (v/v).
View Article and Find Full Text PDFFrom the point of view of systems biology, insight into controlling the functioning of biological systems is conducive to the understanding of their complexness. The development of novel devices, instrumentation and approaches facilitates this endeavor. Here, we show a transistor-like device that can be used to control the kinetics of the consumption of glucose at a yeast-immobilised electrode.
View Article and Find Full Text PDFThe field-effect enzymatic detection (FEED) technique was used to control the kinetics of the enzymatic conversion of glucose to gluconolactone. The glucose-gluconolactone conversion occurring at an enzyme-immobilized electrode, a well-studied process, was confirmed using mass spectrometry. Electrochemical studies showed that the glucose oxidation current depends on the gating voltage VG and the ion concentration of the sample solution.
View Article and Find Full Text PDFThe field-effect enzymatic detection technique has been applied to the amperometric immunoassay of the cancer biomarker, carcinoma antigen 125 (CA 125). The detection adopted a reagentless approach, in which the analyte, CA 125, was immobilized on the detecting electrode, which was modified using carbon nanotubes, and the detection signal was obtained by measuring the reduction peak current of the enzyme that was used to label the antibody. A gating voltage was applied to the detecting electrode, inducing increase in the signal current and therefore providing amplification of the detection signal.
View Article and Find Full Text PDFDetection of analytes on the zepto-molar (10(-21) M) level has been achieved using a field-effect bio-detector. By applying a gating voltage to enzymes immobilized on the working electrode of the detector, amplification of the biocatalytic current was observed. The amplification is attributed to the modification of the tunnel barrier between the enzyme and the electrode by the gating voltage-induced electric field which exists at the solution-electrode interface.
View Article and Find Full Text PDFVoltage-controlled amplification of the output current of an enzymatic detector has been demonstrated. By application of an external voltage between the gating electrode and the working electrode on which the enzyme glucose oxidase was immobilized, the biocatalytic output current of the detector was increased significantly, allowing the detection limit of glucose to be lowered from the millimolar level to the picomolar level. The current amplification could be reversibly controlled by the applied voltage.
View Article and Find Full Text PDFThe ultra-small silicon nanoparticle was shown to be an electrocatalyst for the electrooxidation of glucose. The oxidation appeared to be a first order reaction which involves the transfer of 1 electron. The oxidation potential showed a low onset of -0.
View Article and Find Full Text PDFGlucose sensing electrodes have been realized by immobilizing glucose oxidase (GOx) on unmodified edge plane of highly oriented pyrolytic graphite (epHOPG) and the native oxide of heavily doped silicon (SiO2/Si). Both kinds of electrode show direct interfacial electron transfer due to the redox process of the immobilized GOx. The measured formal potential of the redox process agrees with that of the native enzyme, suggesting that the immobilized GOx has retained its enzymatic activity.
View Article and Find Full Text PDFA simple and versatile approach to constructing patterns on a solid surface using nanoscale objects is demonstrated. The approach is essentially an inlaying process, in which recess patterns fabricated on a surface are selectively filled with nanoscale objects. The objects are anchored firmly on the surface due to the spatial confinement provided by the recess structures.
View Article and Find Full Text PDFThe redox reaction of cytochrome c immobilized on the bare surfaces of microelectrodes and macroscopic electrodes (macroelectrodes) composed of different planes of highly oriented pyrolytic graphite has been investigated using cyclic voltammetry. The protein-immobilized microelectrodes were fabricated using a simple masking method. For both macroelectrodes and microelectrodes, the redox reaction of immobilized cytochrome c needs to be activated by increasing the electrochemical potential maximum of cyclic voltammetry to a high positive value.
View Article and Find Full Text PDFActa Crystallogr D Biol Crystallogr
October 2002
We show with three proteins that trapping and release of the water molecules upon crystallization is a determinant of the crystallization thermodynamics. With HbC, a strong retrograde solubility dependence on temperature yields a high positive enthalpy of 155 kJ mol(-1), i.e.
View Article and Find Full Text PDF