Publications by authors named "Sitnik Robert"

Image network design is a critical factor in image-based 3D shape reconstruction and data processing (especially in the application of combined SfM/MVS methods). This paper aims to present a new approach to designing and planning multi-view imaging networks for dynamic 3D scene reconstruction without preliminary information about object geometry or location. The only constraints are the size of defined measurement volume, the required resolution, and the accuracy of geometric reconstruction.

View Article and Find Full Text PDF

Three-dimensional (3D) shape estimation of the human body has a growing number of applications in medicine, anthropometry, special effects, and many other fields. Therefore, the demand for the high-quality acquisition of a complete and accurate body model is increasing. In this paper, a short survey of current state-of-the-art solutions is provided.

View Article and Find Full Text PDF

This work proposes a change-based segmentation method for applications to cultural heritage (CH) imaging to perform monitoring and assess changes at each surface point. It can be used as a support or component of the 3D sensors to analyze surface geometry changes. In this research, we proposed a new method to identify surface changes employing segmentation based on 3D geometrical data acquired at different time intervals.

View Article and Find Full Text PDF

Augmented reality (AR) delivers virtual information or some of its elements to the real world. This technology, which has been used primarily for entertainment and military applications, has vigorously entered medicine, especially in radiology and surgery, yet has never been used in organ transplantation. AR could be useful in training transplant surgeons, promoting organ donations, graft retrieval and allocation, and microscopic diagnosis of rejection, treatment of complications, and post-transplantation neoplasms.

View Article and Find Full Text PDF

Monitoring the patient's condition during rehabilitation is the key to success in this form of treatment. This is especially important in patients with infantile cerebral palsy (ICP). Objective assessment can be achieved through modern optical measurement techniques.

View Article and Find Full Text PDF

The effect of temperature on three-dimensional (3D) structured light scanners is a very complex issue that, under some conditions, can lead to significant deterioration of performed measurements. In this paper, we present the results of several studies concerning the effect of temperature on the mechanical base of 3D-structured light scanners. We also propose a software compensation method suitable for implementation in any existing scanner.

View Article and Find Full Text PDF

The influence of high-heel footwear on the lumbar lordosis angle, anterior pelvic tilt, and sacral tilt are inconsistently described in the literature. This study aimed to investigate the impact of medium-height heeled footwear on the static posture parameters of homogeneous young adult standing women. Heel geometry, data acquisition process, as well as data analysis and parameter extraction stage, were controlled.

View Article and Find Full Text PDF

This paper presents the results of several studies concerning the effect of temperature on digital cameras. Experiments were performed using three different camera models. The presented results conclusively demonstrate that the typical camera design does not adequately take into account the effect of temperature variation on the device's performance.

View Article and Find Full Text PDF

The existing methods for measuring the shape of the human body in motion are limited in their practical application owing to immaturity, complexity, and/or high price. Therefore, we propose a method based on structured light supported by multispectral separation to achieve multidirectional and parallel acquisition. Single-frame fringe projection is employed in this method for detailed geometry reconstruction.

View Article and Find Full Text PDF

We present a new generation of three-dimensional (3D) measuring systems, developed for the process of crime scene documentation. This measuring system facilitates the preparation of more insightful, complete, and objective documentation for crime scenes. Our system reflects the actual requirements for hierarchical documentation, and it consists of three independent 3D scanners: a laser scanner for overall measurements, a situational structured light scanner for more minute measurements, and a detailed structured light scanner for the most detailed parts of tscene.

View Article and Find Full Text PDF

Background: Low back and pelvic pain is one of the most frequently reported disorders in pregnancy, however etiology and pathology of this problem have not been fully determined. The relationship between back pain experienced during pregnancy and posture remains unclear. It is challenging to measure reliably postural and spinal changes at the time of pregnancy, since most imaging studies cannot be used due to the radiation burden.

View Article and Find Full Text PDF

In forensic documentation with bloodstain pattern analysis (BPA) it is highly desirable to obtain non-invasively overall documentation of a crime scene, but also register in high resolution single evidence objects, like bloodstains. In this study, we propose a hierarchical 3D scanning platform designed according to the top-down approach known from the traditional forensic photography. The overall 3D model of a scene is obtained via integration of laser scans registered from different positions.

View Article and Find Full Text PDF

Objectives: Back pain is a common complaint of pregnant women. The posture, curvatures of the spine and the center of gravity changes are considered as the mechanisms leading to pain. The study aimed to assess spinal curvatures and static postural characteristics with three-dimensional surface topography and search for relationships with the occurrence of back pain complaints among pregnant women.

View Article and Find Full Text PDF

Background: Postural screening remains a powerful tool that can be used to identify children and adolescents with scoliosis or sagittal plane deformities. The aim of this study was to assess the time effectiveness of implemented telediagnostic screening procedures.

Materials And Methods: Medical images (virtual objects) of acquired clouds of points of 100 subjects of both sexes were chosen at random from the database and used for parametric evaluation for this study.

View Article and Find Full Text PDF

We report on a structured light-scanning system, the OGX|4DSCANNER, capable of capturing the surface of a human body with 2 mm spatial resolution at a 60 Hz frame-rate. The performance of modeling the human lower body dynamics is evaluated by comparing the system with the current gold standard, i.e.

View Article and Find Full Text PDF

Background: Several studies consider the school scoliosis screening as controversial. Many authors postulate to improve its clinical effectiveness.

Aim: Authors assumed that three dimensional telediagnostic surface topography measurements allowing measuring several postural deformity indexes and angles of curvatures in sagittal plane may enhance current practice.

View Article and Find Full Text PDF

Faulty postures, scoliosis and sagittal plane deformities should be detected as early as possible to apply preventive and treatment measures against major clinical consequences. To support documentation of the severity of deformity and diminish x-ray exposures, several solutions utilizing analysis of back surface topography data were introduced. A novel approach to automatic recognition and localization of anatomical landmarks of the human back is presented that may provide more repeatable results and speed up the whole procedure.

View Article and Find Full Text PDF

Creating accurate three-dimensional (3D) digitalized models of cultural heritage objects requires that information about surface geometry be integrated with measurements of other material properties like color and reflectance. Up until now, these measurements have been performed in laboratories using manually integrated (subjective) data analyses. We describe an out-of-laboratory bidirectional reflectance distribution function (BRDF) and 3D shape measurement system that implements shape and BRDF measurement in a single setup with BRDF uncertainty evaluation.

View Article and Find Full Text PDF

We present an automatic method for assessment of pectus excavatum severity based on an optical 3-D markerless shape measurement. A four-directional measurement system based on a structured light projection method is built to capture the shape of the body surface of the patients. The system setup is described and typical measurement parameters are given.

View Article and Find Full Text PDF

A four-dimensional [4D--three-dimensional (3D) shape varying in time] shape measurement system is described. A single 3D shape of an object is calculated from only one frame. The projected pattern is composed of sinusoidal intensity fringes and one color-encoded stripe, the analysis of which allows us to find the absolute coordinates of the measured object.

View Article and Find Full Text PDF

Four-dimensional (4D) (3D+time) measurement systems make it possible today to measure objects while moving and deforming. One of the fields where 4D systems prove themselves useful is medicine--particularly orthopedics and neural sciences--where measurement results may be used to estimate dynamic parameters of a patient's movement. Relatively new in 4D, optical full-field shape measurement systems capture more data than standard marker-based systems and open new ways for clinical diagnosis.

View Article and Find Full Text PDF