Background: Absorbable antibacterial envelopes (AAEs) are currently recommended in patients undergoing a transvenous ICD implantation in cases at high risk of infection, who are now preferably implanted with a subcutaneous ICD (S-ICD). Nevertheless, experiences using a combined approach with S-ICD and AAE have not been reported. The aim of our study was to evaluate this strategy in patients at very high risk of infection.

View Article and Find Full Text PDF

A 78 year-old patient with postischaemic dilated cardiomyopathy and severely reduced ejection fraction was implanted with a Boston Scientific RESONATE X4 CRT-D and followed by LATITUDE remote monitoring platform. From the end of January to the end of March 2021 he was hospitalized for COVID19 pneumonia followed by two episodes of acute heart decompensation with bilateral pleural effusion. We remotely followed the patient and identified a typical Heart Logic sensor pattern linked to the COVID19 pneumonia, different from the one linked to the heart failure (HF).

View Article and Find Full Text PDF

Background: The endoscopic ablation system (EAS) is an established ablation device for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). The novel X3 EAS is now equipped with a contiguous circumferential ablation mode (RAPID mode).

Aim: To determine the feasibility of single-shot fashioned ablation using X3.

View Article and Find Full Text PDF

Background: Coronavirus disease 2019 (COVID-19) has shown high morbidity and mortality and the relationship between pulmonary embolism (PE) and COVID-19 is well established in the literature.

Methods: We describe the characteristics of a cohort of COVID-19 patients (EP-COV) hospitalized at our Centre with PE, investigating how COVID-19 may have influenced their outcomes, as compared to patients without COVID-19 hospitalized for PE in the same months of 2020 (EP-2020) and 2019 (EP-2019).

Results: EP-COV patients (n=25) were younger (60.

View Article and Find Full Text PDF

We present a case of ventricular fibrillation triggered by a premature ventricular complex. During ablation from the left coronary cusp, the ablation catheter dislodged inside left main coronary artery, thus resulting in cardiac arrest. We immediately performed angioplasty and stent implantation, and the procedure was accomplished with a guiding catheter left inside the vessel.

View Article and Find Full Text PDF

Background: Recently a double 120 s freeze cryoballoon (CB) pulmonary vein isolation (PVI) protocol proved to be non inferior to a double 240 s freeze protocol in terms of atrial fibrillation (AF) recurrences. We hypothesized that this approach could also result in an increased procedure safety.

Methods: Eighty consecutive patients treated with a double 120 s freeze protocol (Group CB120) were compared with 80 previous consecutive patients treated with a single 240 s freeze protocol (Group CB240).

View Article and Find Full Text PDF

Aims: Anticoagulation for atrial fibrillation patients with liver disease represents a clinical dilemma. We sought to evaluate the efficacy/safety of different anticoagulation, i.e.

View Article and Find Full Text PDF

Right coronary artery lesion is an uncommon and serious complication of typical atrial flutter ablation. We report a case of right coronary artery occlusion during atrial flutter ablation managed with percutaneous coronary intervention, combined with a review of the literature, in order to obtain pathogenetic and epidemiological information about this complication.

View Article and Find Full Text PDF

Objectives: To evaluate the feasibility, procedural data, and lesion characteristics of the anterior line (AL) and roofline (RL) ablation by using ablation index (AI)-guided high power (50 W) among patients with recurrent atrial fibrillation (AF) or atrial tachycardia (AT) after pulmonary vein isolation (PVI).

Methods: Data from 35 consecutive patients with macro-reentrant left atrial tachycardia or substrate at the left atrium anterior wall or roof after previous PVI were collected. Ablation power was set to 50 W, targeting AI 500 for AL and 400 for RL.

View Article and Find Full Text PDF

Aims: Cryoballoon (CB) pulmonary vein isolation (PVI) is an accepted ablation strategy for rhythm control in atrial fibrillation (AF). We describe efficacy and safety in a high volume centre with a long experience in the use of the second-generation CB (CB2).

Methods And Results: Consecutive paroxysmal AF (PAF) or persistent AF (persAF) patients undergoing CB2-PVI were enrolled.

View Article and Find Full Text PDF

Background: Pulmonary vein isolation (PVI) represents the cornerstone in atrial fibrillation ablation. Cryoballoon and laserballoon catheters have emerged as promising devices but lack randomized comparisons. Therefore, we sought to compare efficacy and safety comparing both balloons in patients with persistent and paroxysmal atrial fibrillation (AF).

View Article and Find Full Text PDF

Maze-like linear substrate modification in atrial fibrillation patients nonresponders to pulmonary vein isolation represents a feasible technique to gain left atrial appendage electrical isolation even in the presence of a Watchman occluder device.

View Article and Find Full Text PDF

Background: Time-to-isolation (TTI) guided second-generation cryoballoon (CB2) ablation has been shown to be effective for pulmonary vein isolation (PVI).

Objective: The objective of this paper is to compare the safety and clinical outcome of CB2 PVI using the TTI guided 4 minutes vs 3 minutes freeze protocol.

Methods: This was a propensity-matched study based on an institutional database.

View Article and Find Full Text PDF

Background: High-power, short-duration ablation for pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF) facilitates the procedure and improve effectiveness; however, esophageal injury remains a safety concern.

Objective: The purpose of this study was to investigate the role of luminal esophageal temperature (LET) monitoring during high-power ablation for PVI in terms of endoscopic esophageal lesion.

Methods: Patients with symptomatic AF underwent ablation index-guided high-power (AI-HP) PVI (50 W; AI anterior wall/posterior wall: 550/400).

View Article and Find Full Text PDF

Aims: Systematic data on phrenic nerve palsy (PNP) associated with contemporary balloon ablation techniques (cryoballoon [CBA] vs laser balloon [LBA]) are sparse. We aimed to investigate the incidence, characteristics, and clinical recovery course in patients with PNP who underwent CBA or LBA.

Methods And Results: A total of 2433 consecutive patients who underwent balloon-based pulmonary vein isolation (CBA: n = 1720 and LBA: n = 713) were retrospectively identified.

View Article and Find Full Text PDF

Objectives: This study sought to determine whether cardiac magnetic resonance (CMR) may identify structural heart disease (SHD) in patients with ventricular arrhythmia who had echocardiography ruled out pathological findings.

Background: Approximately one-half of sudden cardiac deaths are attributable to malignant VA. Echocardiography is commonly used to identify SHD that is the most frequent substrate of VA.

View Article and Find Full Text PDF

Background: Aim of the study was to evaluate image quality, radiation exposure and diagnostic accuracy of coronary CT angiography (CCTA) performed with a novel cardiac CT scanner in patients with very high heart rate (HR).

Methods: We prospectively enrolled 202 patients (111 men, mean age 66±8years) with suspected coronary artery disease who underwent CCTA with a whole-organ volumetric CT scanner. The HR during the scan was ≥80bpm in 100 patients (Group 1), while it was ≤65bpm in the remaining 102 patients (Group 2).

View Article and Find Full Text PDF

A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_session6lgk46ouip1ul33mbs0rolqrc2a2e4t1): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once