Publications by authors named "Simona Lago"

In this work, the experimental results of deuterium oxide density at high pressure and in a wide range of temperatures, by means of the pseudo-isochoric method, are presented. A specific stainless steel cell was devised to be used as a pycnometer and filled with variable mass of heavy water. The latter was measured by weighing with an analytical balance and using the substitution method.

View Article and Find Full Text PDF

In this work, accurate density measurements of subcooled water (freshly double-distilled water) were performed along eight constant-mass curves in the temperature range of (243 to 283) K and in the pressure range of (140 to 400) MPa, by a pseudo-isochoric method. The experimental apparatus mainly consisted of a high pressure vessel, especially designed for this experiment, of known volume as a function of temperature and pressure, used to perform measurements in the T-p range under study. The density of subcooled water was obtained by measuring the equilibrium pressure at different temperatures, keeping the mass constant.

View Article and Find Full Text PDF

Tissue-mimicking phantoms play a crucial role in medical ultrasound research because they can simulate biological soft tissues. In last years, many types of polymeric tissues have been proposed and characterized from an acoustical and a thermal point of view, but, rarely, a deep discussion about the quality of the measurements, in terms of the uncertainty evaluation, has been reported. In this work, considering the necessity to develop laboratory standards for the measurement of ultrasonic exposure and dose quantities, a detailed description of the experimental apparatuses for the sound speed and the attenuation coefficient measurements is given, focusing the attention on the uncertainty evaluation both of the results and analysis algorithms.

View Article and Find Full Text PDF