Aims: Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking.
View Article and Find Full Text PDFBackground And Purpose: Rotating hinged knee implants are highly constrained prostheses used in cases in which adequate stability is mandatory. Due to their constraint nature, multidirectional stresses are directed through the bone-cement-implant interface, which might affect fixation and survival. The goal of this study was to assess micromotion of a fully cemented rotating hinged implant using radiostereometric analysis (RSA).
View Article and Find Full Text PDFBackground: Clinical observations revealed higher rates of aseptic loosening for hybrid fixated rotating hinge knee implants compared to fully cemented ones. We hypothesize that the use of a fully cemented fixation technique had a higher survival rate for aseptic loosening compared to a hybrid fixation technique in a rotating hinge knee implant.
Methods: All procedures of patients who were treated with the RT-PLUS rotating hinge knee implant (Smith & Nephew, Memphis, TN) between 2010 and 2018 were included.
The aim of the study is to compare the overall complication rate and in particular lag screw cut-out between the Trochanteric Gamma Nail and the Gamma 3 Nail. A total of 294 implants (Trochanteric Gamma Nail= 132 and Gamma 3 Nail=163) in 291 patients were analysed. All clinical data was obtained from the patients medical records.
View Article and Find Full Text PDFAcromioclavicular dislocation combined with a midshaft clavicle fracture is a rare traumatic shoulder problem. Various treatment options have been described in literature. We describe a new technique using a hook plate and coracoclavicular sling to replace the ruptured coracoclavicular ligaments in combination with plate osteosynthesis of the clavicle fracture.
View Article and Find Full Text PDFHinged prostheses have been increasingly utilized in complex and revision total knee arthroplasty (TKA) cases requiring additional mechanical support and global stability. However, there is limited data detailing the outcomes of modern hinge designs in these procedures. The aim of this study is to report a minimum 2-year functional outcomes and survivorship of a novel-guided motion-hinged knee TKA system.
View Article and Find Full Text PDFBackground: Instability is an infrequently encountered diagnosis in rotating hinge knee (rHK) implants. With the introduction of a new rHK implant, we encountered multiple patients who complained of instability. This article presents its prevalence while describing our diagnostic and treatment algorithms.
View Article and Find Full Text PDFAims: One of the instruments in the orthopaedic surgeon's armamentarium to face the challenges associated with periprosthetic fracture around the stem of a hip replacement is the tapered, fluted, modular, titanium (TFMT) stem. Our aim was to study its clinical and radiological outcomes.
Patients And Methods: During the period 2010-2016 86 patients (55 females; median age 78.
Background/objective: Activity is increasingly being recognized as a highly relevant parameter in all areas of healthcare for diagnosis, treatment, or outcome assessment, especially in orthopaedics where the movement apparatus is directly affected. Therefore, the aim of this study was to develop, describe, and clinically validate a generic activity-monitoring algorithm, satisfying a combination of three criteria. The algorithm must be able to identify, count, and time a large set of relevant daily activities.
View Article and Find Full Text PDFBackground: A growing need in clinical practice of rehabilitation and orthopaedic medicine is for objective outcome tools to estimate physical activity. Current techniques show limited validity or are too demanding for routine clinical use. Accelerometer-based activity monitors (AMs) have shown promise for measuring physical activity in healthy people but lack validity in impaired patients.
View Article and Find Full Text PDFGait analysis has widely been accepted as an objective measure of function and clinical outcome. Ambulatory accelerometer-based gait analysis has emerged as a clinically more feasible alternative to optical motion capture systems but does not provide kinematic characterisation to identify disease dependent mechanisms causing walking disability. This study investigated the potential of a single inertial sensor to derive frontal plane motion of the pelvis (i.
View Article and Find Full Text PDFThough rare, many anomalous origins of long head of the biceps tendon (LHBT) have been reported in the literature. Anatomic variations commonly explained are a third humeral head, anomalous insertion, congenital absence and adherence to the rotator cuff. We report a rare case who underwent shoulder arthroscopy with impingement symptoms where in LHBT was found to be bifurcated with a part attached to superior labrum and the other part to the posterior capsule of joint.
View Article and Find Full Text PDF