Publications by authors named "Simon Lessard"

The Flow Diverter is a self-expandable braided stent that has helped improve the effectiveness of cerebral aneurysm treatment during the last decade. The Flow Diverter's efficiency heavily relies on proper decision-making during the pre-operative phase, which is currently based on static measurements that fail to account for vessel or tissue deformation. In the context of providing realistic measurements, a biomechanical computational method is designed to aid physicians in predicting patient-specific treatment outcomes.

View Article and Find Full Text PDF
Article Synopsis
  • Researchers are exploring the use of external actuation to navigate drug-eluting microrobots in the bloodstream for more targeted drug delivery in cancer treatment.
  • An algorithm was developed to optimize patient positioning based on gravity, enhancing the navigation of magnetic microrobots (MMRs) through the liver arteries in pigs.
  • The results showed a significant increase in the delivery efficiency of MMRs to liver lobes, indicating this technique could improve treatment for patients with liver cancer.
View Article and Find Full Text PDF

Background: Evaluate how specific morphologic aspects of abdominal aortic aneurysms (AAAs), including asymmetries, curvatures, tortuosities, and angulations, among others can influence the intrinsic biomechanical properties of the AAA's wall. This study analyzed the correlation of geometric measurements (1-dimensional, 2-dimensional, and 3-dimensional) of preoperative tomographic images of AAA with uniaxial biomechanical tests of the arterial wall fragments of these AAA obtained in open surgical repair of aneurysms.

Methods: It was a multicenter, experimental, and observational study, and initially 54 individuals were selected who underwent open surgical of AAA, with valid biomechanical tests of the anterior wall of the AAA.

View Article and Find Full Text PDF

Background: Abdominal aortic aneurysm (AAA) rupture prediction based on sex and diameter could be improved. The goal was to assess whether aortic calcification distribution could better predict AAA rupture through machine learning and LASSO regression.

Methodology: In this retrospective study, 80 patients treated for a ruptured AAA between January 2001 and August 2018 were matched with 80 non-ruptured patients based on maximal AAA diameter, age, and sex.

View Article and Find Full Text PDF

Objective: Cardiac gating, synchronizing medical scans with cardiac activity, is widely used to make quantitative measurements of physiological events and to obtain high-quality scans free of pulsatile artefacts. This can provide important information for disease diagnosis, targeted control of medical microrobots, etc. The current work proposes a low-cost, self-adaptive, MRI-compatible cardiac gating system.

View Article and Find Full Text PDF

Four-dimensional (4D) flow magnetic resonance imaging (MRI) is a leading-edge imaging technique and has numerous medicinal applications. In vitro 4D flow MRI can offer some advantages over in vivo ones, especially in accurately controlling flow rate (gold standard), removing patient and user-specific variations, and minimizing animal testing. Here, a complete testing method and a respiratory-motion-simulating platform are proposed for in vitro validation of 4D flow MRI.

View Article and Find Full Text PDF

Objective: Superparamagnetic nanoparticles (SPIONs) can be combined with tumor chemoembolization agents to form magnetic drug-eluting beads (MDEBs), which are navigated magnetically in the MRI scanner through the vascular system. We aim to develop a method to accurately quantify and localize these particles and to validate the method in phantoms and swine models.

Methods: MDEBs were made of FeO SPIONs.

View Article and Find Full Text PDF

Since the 1990s, endovascular aortic aneurysm repair (EVAR) has become a common alternative to open surgery for the treatment of abdominal aortic aneurysms (AAAs). To aid the deployment of stent-grafts, fluoroscopic image guidance can be enhanced using preoperative simulation and intraoperative image fusion techniques. However, the impact of calcification (Ca) presence on the guidance accuracy of such techniques is yet to be considered.

View Article and Find Full Text PDF

Introduction: Magnetic resonance navigation (MRN) uses MRI gradients to steer magnetic drug-eluting beads (MDEBs) across vascular bifurcations. We aim to experimentally verify our theoretical forces balance model (gravitational, thrust, friction, buoyant and gradient steering forces) to improve the MRN targeted success rate.

Method: A single-bifurcation phantom (3 mm inner diameter) made of poly-vinyl alcohol was connected to a cardiac pump at 0.

View Article and Find Full Text PDF

Abdominal aortic aneurysm (AAA) is an asymptomatic condition due to the dilation of abdominal aorta along with progressive wall degeneration, where rupture of AAA is life-threatening. Failures of AAA endovascular repair (EVAR) reflect our inadequate knowledge about the complex interaction between the aortic wall and medical devices. In this regard, we are presenting a hydrogel-based anthropomorphic mockup (AMM) to better understand the biomechanical constraints during EVAR.

View Article and Find Full Text PDF

Abdominal aortic aneurysms (AAA) are localized, commonly occurring aortic dilations. Following rupture only immediate treatment can prevent morbidity and mortality. AAA maximal diameter and growth are the current metrics to evaluate the associated risk and plan intervention.

View Article and Find Full Text PDF

Blood vessel injury during image-guided brain biopsy poses a risk of hemorrhage. Approaches that reduce this risk may minimize related patient morbidity. We present here an intraoperative imaging device that has the potential to detect the brain vasculature .

View Article and Find Full Text PDF

Endovascular aneurysm repair is rapidly emerging as the primary preferred method for treating abdominal aortic aneurysm. In this image-guided interventional procedure, to obtain the roadmap and decrease contrast injections, preoperative CT images are overlaid onto live fluoroscopy images using various 2D/3D image fusion techniques. However, the structural changes due to the insertion of stiff tools degrade the fusion accuracy.

View Article and Find Full Text PDF

Abdominal aortic aneurysms (AAA) are localized, commonly-occurring dilations of the aorta. When equilibrium between blood pressure (loading) and wall mechanical resistance is lost, rupture ensues, and patient death follows, if not treated immediately. Experimental and numerical analyses of flow patterns in arteries show direct correlations between wall shear stress and wall mechano-adaptation with the development of zones prone to thrombus formation.

View Article and Find Full Text PDF

Here we address the automatic segmentation of endovascular devices used in the endovascular repair (EVAR) of abdominal aortic aneurysms (AAA) that deform vascular tissues. Using this approach, the vascular structure is automatically reshaped solving the issue of misregistration observed on 2D/3D image fusion for EVAR guidance. The endovascular devices we considered are the graduated pigtail catheter (PC) used for contrast injection and the stent-graft delivery device (DD).

View Article and Find Full Text PDF

Purpose: To evaluate the accuracy and source of errors using a two-dimensional (2D)/three-dimensional (3D) fusion road map for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm.

Materials And Methods: A rigid 2D/3D road map was tested in 16 patients undergoing EVAR. After 3D/3D manual registration of preoperative multidetector computed tomography (CT) and cone beam CT, abdominal aortic aneurysm outlines were overlaid on live fluoroscopy/digital subtraction angiography (DSA).

View Article and Find Full Text PDF

Detection of sulfur by optical emission spectroscopy generally presents some difficulties because the strongest lines are in the vacuum UV below 185 nm and therefore are readily absorbed by oxygen molecules in air. A novel concept for a low-cost and efficient system to detect sulfur using near-IR bands by laser-induced breakdown spectroscopy is here proposed. This concept is based on customized thick holographic gratings as spectral filtering elements.

View Article and Find Full Text PDF

This paper presents a new method for guidewire tracking on fluoroscopic images from endovascular brain intervention. The combination of algorithms chosen can be implemented in real time, so that it can be used in an augmented reality 3D representation to assist physicians performing these interventions. A ribbon-like morphing process combined with a minimal path optimization algorithm is used to track lateral motion between successive frames.

View Article and Find Full Text PDF