Publications by authors named "Silvio J Mauro"

Aim: The aim of this study was to investigate the association of different degradations on the roughness, gloss, and color changes of microhybrid composites.

Materials And Methods: Ten specimens were prepared for Charisma, Amelogen Plus, Point 4, and Opallis resins. Surfaces were polished and baseline measurements of roughness, gloss, and color were recorded.

View Article and Find Full Text PDF

The aim of this study was to evaluate the shear bond strength of resin composite repairs with and without aging of the surface to be repaired, using different adhesive systems and resin composites. Ninety specimens were prepared: 10 for the Control Group (GC - without repair); 40 for Group I (GI - repairs after 7 days) and 40 for Group II (GII - repairs after 180 days). Groups I and II were divided into 4 subgroups of 10 specimens each, according to the adhesive system and composite resin used: A) Adper Scotch Bond Multipurpose + Filtek Z350 XT; B) Adper Single Bond Plus + Filtek Z350 XT; C) Adper Scotch Bond Multipurpose + Esthet-X; D) Adper Single Bond Plus + Esthet-X.

View Article and Find Full Text PDF

The objective of this study was to analyze the formation of resin tags on enamel surfaces submitted or not to enamel microabrasion technique. Thirteen undergraduate dental students received removable acrylic palatal appliances on which four sections from intact premolars were fixed, measuring 4.0 mm x 4.

View Article and Find Full Text PDF

Objective: To analyze the clinical behavior of 2 pit and fissure sealants through clinical/computerized evaluation.

Method And Materials: Occlusal sealants were placed on maxillary and mandibular first and second premolars according to a split-mouth design. All premolars were sealed with either Concise (3M Espe) or Prisma Shield (Caulk/Dentsply) sealant agents.

View Article and Find Full Text PDF

Unlabelled: The purpose of this study was to employ photographic evaluation to observe the presence or absence of bubbles in pit and fissure sealants Concise and Prisma Shield, at 7 days, 18 months, 36 months and 11 years after accomplishment of treatment.

Methods: A hematoxylin-based staining solution was applied to the occlusal surface at the study periods, which allowed assessment of the sealing material on the surface. All occlusal surfaces were photographed and the photographs corresponding to each period were subjected to photographic evaluation.

View Article and Find Full Text PDF

Introduction: The evolution of light curing units can be noticed by the different systems recently introduced. The technology of LED units promises longer lifetime, without heating and with production of specific light for activation of camphorquinone. However, further studies are still required to check the real curing effectiveness of these units.

View Article and Find Full Text PDF

The clinical behavior of Concise and Prisma Shield sealants for pit and fissure was analyzed by clinical/photographic evaluation. A hematoxylin-based staining solution was applied to the occlusal surface 7 days, 18 months, 36 months, and 11 years after the occlusal sealing, thus allowing the sealant material on the surface to be checked. At each analysis time, each occlusal surface was photographed, and the photographs corresponding to each time were submitted to clinical/photographic evaluation.

View Article and Find Full Text PDF