The endogenous nitrate concentration in fresh meat and the residual nitrate and nitrite contents after curing are related to food quality and safety. Most ion chromatography (IC) methods suffer from interferences, especially in fresh meat samples, in which the endogenous nitrate content is low, and in cured meat products, in which other nitrogenous compounds can interfere with the separation of inorganic anions. One of the major classes of interfering compounds in fresh meat are sugar phosphates, which originate from glycolysis during the conversion of muscle glycogen to lactic acid.
View Article and Find Full Text PDFA rapid and selective cation exchange chromatographic method coupled to integrated pulsed amperometric detection (PAD) has been developed to quantify biogenic amines in chocolate. The method is based on gradient elution of aqueous methanesulfonic acid with post column addition of strong base to obtain suitable conditions for amperometric detection. A potential waveform able to keep long time performance of the Au disposable electrode was set up.
View Article and Find Full Text PDFA versatile liquid chromatographic platform has been developed for analysing underivatized carbohydrates using high performance anion exchange chromatography (HPAEC) followed by an inert PEEK splitter that splits the effluent to the integrated pulsed amperometric detector (IPAD) and to an on-line single quadrupole mass spectrometer (MS). Common eluents for HPAEC such as sodium hydroxide and sodium acetate are beneficial for the amperometric detection but not compatible with electrospray ionisation (ESI). Therefore a membrane-desalting device was installed after the splitter and prior to the ESI interface converting sodium hydroxide into water and sodium acetate into acetic acid.
View Article and Find Full Text PDFBromate, a well known by-product of the ozonation of drinking water, has been included among the substances which have to be monitored in the drinking water according to the last EC Directive 251/98 on potable water with a regulated limit of 10 microg l(-1). The need of performing routine analysis at this limit is a driving force for the developing of new simple and sensitive methods of detection, which should be also able to overcome the effect of matrix composition. This work explored the use of mass spectrometry detection with electrospray ionisation hyphenated to a reagent free ion chromatograph with hydroxide gradient elution for the determination of bromate in drinking water.
View Article and Find Full Text PDFThe determination of free sulfide and cyanide by pulsed amperometric detection (PAD) at a silver-working electrode was improved through a deep de-oxygenation (at least 10 min) of both standard and real solutions containing the two analytes and adopting a two-potential waveform able to eliminate Ag working electrode fouling. The waveform stepped around the oxidation of Ag in the presence of 0.1-0.