Background: In order to optimise the support of children with cochlear implants (CI), it is very important to detect slow developmental processes as early as possible. Data from the LittlEARS® Auditory Questionnaire (LEAQ) from children with early bilateral CI are evaluated and presented in relation to age and hearing age and compared with language development data recorded later.
Materials And Methods: This retrospective multicentre study included data from a total of 554 children for whom at least one LEAQ was completed during the course of CI rehabilitation.
Eur Arch Otorhinolaryngol
August 2024
Purpose: The aim of this study was to investigate whether the fitting data of children with Cochlear implants (CI) and severe additional disabilities (CAD) differ compared to children with CI but without additional disabilities (CnonAD).
Methods: In this retrospective analysis, 76 CI cases (fitted ears) from CAD were included and matched with 76 cases from CnonAD. The subjective set values, such as pulse width (PW), threshold (T) and most comfortable (MC) levels were recorded.
Background: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery.
Methods: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same.
Eur Arch Otorhinolaryngol
September 2024
Introduction: The treatment of patients with a cochlear implant (CI) is usually an elective, complex and interdisciplinary process. As an important source of information, patients often access the internet prior to treatment. The quality of internet-based information regarding thematic coverage has not yet been analysed in detail.
View Article and Find Full Text PDFBackground: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined.
Materials And Methods: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation.
Background: The Association of the Scientific Medical Societies in Germany (AWMF) clinical practice guideline on cochlear implant (CI) treatment, which was updated in 2020, defined the entire process of CI care for the first time. In the present study, the feasibility and results of very early rehabilitation were examined.
Materials And Methods: The intervention group (IG) comprised 54 patients in whom rehabilitation was initiated within 14 (maximally 28) days after implantation.
Purpose: In recent years, the number of elderly cochlear implant (CI) candidates is continuously rising. In addition to the audiological improvement, other positive effects of CI treatment can also be observed in clinical routine. The "quality of life" as a parameter of success directly experienced by the patient is increasingly becoming the focus of clinical research.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
March 2024
Purpose: Monocentric, prospective study to investigate whether concomitant support of cochlear implant (CI) patients by CI-trained otolaryngologists and application of a standardized head bandage can minimize potential complications during magnetic resonance imaging (MRI).
Methods: Thirty-seven patients with 46 CIs underwent MRI with a prophylactic head bandage. All participants and the otolaryngologist at the CI center completed pre- and post-MRI questionnaires documenting body region scanned, duration of MRI and bandage wear, field strength during the scan, and any complications.
Eur Arch Otorhinolaryngol
October 2023
Purpose: Bilateral cochlear implantation is an effective treatment for patients with bilateral profound hearing loss. In contrast to children, adults mostly choose a sequential surgery. This study addresses whether simultaneous bilateral CI is associated with higher rates of complications compared to sequential implantation.
View Article and Find Full Text PDFBackground: Due to the COVID-19 pandemic, all essential treatment must adhere to strict health and hygiene protocols. New measures have been introduced in CI treatment centres in order to safely accommodate families and continue to provide effective follow-up CI therapy for children implanted with CIs.
Objectives: The aim of this study was to document, over the course of the pandemic, how patients' parents viewed the likelihood and danger of infection and how necessary they thought the newly implemented protocols were.
Objectives: To correlate the radiological assessment of the mastoid facial canal in postoperative cochlear implant (CI) cone-beam CT (CBCT) and other possible contributing clinical or implant-related factors with postoperative facial nerve stimulation (FNS) occurrence.
Methods: Two experienced radiologists evaluated retrospectively 215 postoperative post-CI CBCT examinations. The mastoid facial canal diameter, wall thickness, distance between the electrode cable and mastoid facial canal, and facial-chorda tympani angle were assessed.
Vertigo is a common side effect of cochlear implant (CI) treatment. This prospective study examines the incidence of postoperative vertigo over time and aims to analyze influencing factors such as electrode design and insertion angle (IA). This is a prospective study which has been conducted at a tertiary referral center (academic hospital).
View Article and Find Full Text PDFObjective: To examine the number of magnetic resonance imaging (MRI) examinations performed in patients with hearing implants and to quantify side effects or complications related to this procedure.
Study Design: Questionnaire.
Setting: Tertiary referral center, academic hospital.
Rationale And Objectives: To evaluate cone-beam computed-tomography (CBCT) images of the temporal bone for radiological delineation, metal artifacts, and accuracy for localization of six different electrode arrays after cochlear device implantation.
Materials And Methods: This retrospective study included 116 patients who underwent CBCT (120kV, 7.1mA) within 24 hours after cochlear device implantation.
The purpose of this article is to evaluate subjective image quality and diagnostic accuracy to determine cochlear implant (CI) electrode position in a temporal bone (TB) specimen on cone-beam CT (CBCT) versus MDCT. In this retrospective study, two radiologists independently reviewed CBCT (96-kV and 120-kV settings) and MDCT images of 20 TB specimens after electrode implantation. Qualitative evaluation of bone structures of the otic capsule, inner and outer cochlear wall, osseous spiral lamina, electrode position relative to the osseous spiral lamina, visualization of single electrode contacts on the array, metal artifacts, and overall image quality was performed using a five-point scale.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
November 2021
Introduction: For cochlear implants (CI) with removable magnets, a pressure bandage usually is recommended during MR imaging to avoid magnet dislocation. Nevertheless, this complication is regularly observed despite applying a pressure bandage. The aim of this study was to compare various bandaging techniques to avoid magnet displacement.
View Article and Find Full Text PDFEur Arch Otorhinolaryngol
May 2020
Purpose: An increasing number of cochlear implant (CI) users is examined by magnetic resonance imaging which may cause the displacement of the implant magnet. This complication prevents the usage of the external processor and has to be treated surgically in most cases. The purpose of this study is to analyze the results of the surgical intervention and the consequences for the CI recipients.
View Article and Find Full Text PDFObjective: The objective of this prospective, single-subject, repeated measures study was to evaluate the audiological benefit and patient satisfaction with an adhesive, pressure-free bone conduction hearing system (ADHEAR; MED-EL, Innsbruck, Austria) in patients who underwent middle ear surgery with transient hearing loss due to auditory canal tamponade.
Methods: Eleven adult subjects suffering from transient conductive hearing loss were enrolled in the study and followed up to 3 weeks after middle ear surgery. Bone and air conduction thresholds were measured pre and postoperatively to evaluate eligibility for enrollment.
Eur Arch Otorhinolaryngol
February 2020
Purpose: Electrode migration is a rare, but relevant complication in cochlear implant (CI) surgery. An effective countermeasure is to create a bone groove in the facial recess to secure the electrode lead. We use this method routinely since 2013, but still experienced sporadic electrode migration events most likely due to an improper surgical execution.
View Article and Find Full Text PDFHypothesis: The risk of electrode migration in cochlear implant (CI) surgery can be reduced by securing the electrode lead in a bone groove in the chorda-facial angle.
Background: Electrode migration is an important complication in CI surgery, which affects hearing performance, may induce pain and facial nerve stimulation, and requires surgical revision. A potential method to secure the electrode is to use a bone groove created in the facial recess to fixate the electrode lead.
Objectives: To report on electrode array measurements for the Nucleus CI532 Slim Modiolar Electrode device including: ECAP thresholds, electrode impedances, and psychophysical comfort levels, as well as speech perception results pre- and post-operatively and standardized evaluations of quality of life.
Methods: Forty-four subjects were implanted with the CI532. Electrically evoked compound action potential (ECAP) thresholds and impedances were measured using automatic Neural Response Telemetry intra-operatively, at activation and at six months post implant.
Objective: Incidence and clinical presentation of tip foldover during cochlear implantation (CI).
Study Design: Retrospective case review.
Setting: Tertiary referral university hospital.
Objective: This study reviewed outcomes of hearing preservation (HP) surgery depending on the angle of insertion (AOI) in a cochlear implant (CI) patient population who used electric stimulation (ES) or combined electric-acoustic stimulation (EAS).
Study Design: Retrospective case review.
Setting: Tertiary referral university hospital.
Int J Pediatr Otorhinolaryngol
December 2017
A young bilateral cochlear implant (CI) user required magnetic resonance imaging (MRI) to determine the cause of hydrocephalus. The images obtained with the CIs in place were not diagnostically useful due to large artefacts generated by the CI magnets. We obtained useful images by bilaterally explanting the CI-magnets and replacing them with non-magnetic placeholder dummies then conducted the imaging.
View Article and Find Full Text PDFAims: The Nucleus CI532 cochlear implant incorporates a new precurved electrode array, i.e., the Slim Modiolar electrode (SME), which is designed to bring electrode contacts close to the medial wall of the cochlea while avoiding trauma due to scalar dislocation or contact with the lateral wall during insertion.
View Article and Find Full Text PDF