Publications by authors named "Silja Holopainen"

A comparison between the absolute gonioreflectometric scales at the Helsinki University of Technology (TKK) and the Physikalisch-Technische Bundesanstalt (PTB) has been accomplished. Six different reflection standards were measured for their 0:45 spectral radiance factor between 250 and 1650 nm in 10 nm intervals. Also, the 0:d reflectance factor between 400 and 1600 nm in 100 nm intervals was determined from goniometric reflectance measurements over polar angles with subsequent integration within the hemisphere above the sample.

View Article and Find Full Text PDF

A goniofluorometer has been built that is capable of measuring in various viewing angles ranging from 10 degrees to 90 degrees . The incident angle can be varied from 0 degrees to 8 degrees . The goniofluorometer can measure bispectral luminescent radiance factors in the wavelength range of 250-800 nm.