Background: To meet the WHO target of eradicating yaws by 2030, highly sensitive and specific diagnostic tools are needed. A multiplex Treponema pallidum-Haemophilus ducreyi loop-mediated isothermal amplification (TPHD-LAMP) test holds promise as a near-patient diagnostic tool for yaws and H ducreyi. We conducted a prospective evaluation in Cameroon, Côte d'Ivoire, Ghana, and the Republic of the Congo to determine the diagnostic accuracy of the TPHD-LAMP test, as well as to assess its acceptability, feasibility, and cost.
View Article and Find Full Text PDFIntroduction: Yaws, caused by the bacterium subsp. is a neglected tropical disease targeted for eradication by 2030. Improved diagnostics will be essential to meet this goal.
View Article and Find Full Text PDFBackground: In this work, a platform was developed and tested to allow to detect a variety of candidate viral, bacterial and parasitic pathogens, for acute fever of unknown origin. The platform is based on a centrifugal microfluidic cartridge, the LabDisk ("FeverDisk" for the specific application), which integrates all necessary reagents for sample-to-answer analysis and is processed by a compact, point-of-care compatible device.
Methodology/principal Findings: A sample volume of 200 μL per FeverDisk was used.
This paper presents a universal point-of-care system for fully automated quantification of human T-cell lymphotropic virus type 1 (HTLV-1) proviral load, including genomic RNA, based on digital reverse RNA transcription and c-DNA amplification by MD LAMP (mediator displacement loop-mediated isothermal amplification). A disposable microfluidic LabDisk with pre-stored reagents performs automated nucleic acid extraction, reaction setup, emulsification, reverse transcription, digital DNA amplification, and quantitative fluorogenic endpoint detection with universal reporter molecules. Automated nucleic acid extraction from a suspension of HTLV-1-infected CD4+ T-lymphocytes (MT-2 cells) yielded 8 ± 7 viral nucleic acid copies per MT-2 cell, very similar to the manual reference extraction (7 ± 2 nucleic acid copies).
View Article and Find Full Text PDFWe implement dual-volume centrifugal step emulsification on a single chip to extend the dynamic range of digital assays. Compared to published single-volume approaches, the range between the lower detection limit (LDL) and the upper limit of quantification (ULQ) increases by two orders of magnitude. In comparison to existing multivolume approaches, the dual-volume centrifugal step emulsification requires neither complex manufacturing nor specialized equipment.
View Article and Find Full Text PDFTwo one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of Zika virus (ZIKV) were developed, based on two different primer design approaches: (1) open source, based on a combination of sequence diversity clustering (phylogeny and principal component analysis) and LAVA algorithm, using 45 whole genome ZIKV sequences retrieved from the National Center for Biotechnology Information (NCBI) database; (2) standard software for LAMP primer design (Primer Explorer V4), using 59 sequences of the ZIKV 3' UTR. The assays were firstly evaluated with External Quality Assessment panels from INSTAND e.V.
View Article and Find Full Text PDFYaws, a neglected tropical disease caused by the bacterium Treponema pallidum subspecies pertenue, manifests as ulcerative skin lesions. Nucleic acid amplification tests, like loop-mediated isothermal amplification (LAMP), are versatile tools to distinguish yaws from infections that cause similar skin lesions, primarily Haemophilus ducreyi. We developed a novel molecular test to simultaneously detect T.
View Article and Find Full Text PDFBackground: A single-tube one-step real-time reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay for rapid detection of chikungunya virus (CHIKV) targeting the conserved 6K-E1 target region was developed. The assay was validated with sera collected from a CHIKV outbreak in Senegal in 2015.
Methodology/principal Findings: A novel design approach by combining Principal Component Analysis and phylogenetic analysis of 110 available CHIKV sequences and the LAMP oligonucleotide design software LAVA was used.
Background: 4 one-step, real-time, reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays were developed for the detection of dengue virus (DENV) serotypes by considering 2,056 full genome DENV sequences. DENV1 and DENV2 RT-LAMP assays were validated with 31 blood and 11 serum samples from Tanzania, Senegal, Sudan and Mauritania. DENV3 and DENV4 RT-LAMP assays were validated with 25 serum samples from Cambodia.
View Article and Find Full Text PDFWe show proof of concept for gene targets (polA, tprL, and TP_0619) that can be used in loop-mediated isothermal amplification (LAMP) assays to rapidly differentiate infection with any of the three Treponema pallidum subspecies (pallidum (TPA), pertenue (TPE), and endemicum (TEN)) and which are known to infect humans and nonhuman primates (NHPs). Four TPA, six human, and two NHP TPE strains, as well as two human TEN strains were used to establish and validate the LAMP assays. All three LAMP assays were highly specific for the target DNA.
View Article and Find Full Text PDFA variety of real-time detection techniques for loop-mediated isothermal amplification (LAMP) based on the change in fluorescence intensity during DNA amplification enable simultaneous detection of multiple targets. However, these techniques depend on fluorogenic probes containing target-specific sequences. That complicates the adaption to different targets leading to time-consuming assay optimization.
View Article and Find Full Text PDFThe bacterium Treponema pallidum is known to cause syphilis (ssp. pallidum), yaws (ssp. pertenue), and endemic syphilis (ssp.
View Article and Find Full Text PDFThere is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes.
View Article and Find Full Text PDFReal-time reverse transcription loop-mediated isothermal amplification (real-time RT-LAMP) holds substantial potential as a highly sensitive, specific, and easy-to-perform molecular technique for pathogen detection in clinical samples. In the current study, the analytical and diagnostic performance of 2 commercial real-time RT-LAMP kits, Avian Flu H5 and Avian Flu H7, in detecting Avian influenza virus (AIV) infections were evaluated and compared with validated real-time reverse transcription polymerase chain reaction (RT-PCR) assays using RNA from reference virus isolates of subtypes H5 (n = 24) and H7 (n = 25) and of phylogenetically related subtypes (n = 20). When real-time RT-LAMP was carried out according to the recommendations of the manufacturer, 3 out of 24 H5 isolates and 8 out of 25 H7 reference strains were not detected.
View Article and Find Full Text PDF