Early life adverse experiences, including childhood maltreatment, are major risk factors for psychopathology, including anxiety disorders with dysregulated fear responses. Consistent with human studies, maltreatment by the mother (MALT) leads to increased emotional reactivity in rhesus monkey infants. Whether this persists and results in altered emotion regulation, due to enhanced fear learning or impaired utilization of safety signals as shown in human stress-related disorders, is unclear.
View Article and Find Full Text PDFObjectives: Pediatric chronic pain is common and can be detrimental to children's social, emotional, and school functioning. Nonpharmacological approaches to chronic pain, like cognitive- behavioral therapy (CBT), can be effective. Schools could provide children with chronic pain access to these interventions.
View Article and Find Full Text PDFBackground: Acute intracranial occlusion of the internal carotid artery (ICA) can be distinguished into (a) occlusion of the terminal ICA, involving the proximal segments of the middle or anterior cerebral artery (ICA-L/-T) and (b) non-terminal intracranial occlusions of the ICA with patent circle of Willis (ICA-I). While patients with ICA-L/-T occlusion were included in all randomized controlled trials on endovascular therapy (EVT) in anterior large vessel occlusion, data on EVT in ICA-I occlusion is scarce. We thus aimed to evaluate effectiveness and safety of EVT in ICA-I occlusions in comparison to ICA-L/-T occlusions.
View Article and Find Full Text PDFBackground And Objectives: Flow Redirection Endoluminal Device (FRED) X is a new generation flow diverter with an antithrombotic surface coating. This study compares the procedural safety and short-term efficacy of FRED X with its uncoated predecessor, the FRED.
Methods: Patients treated with FRED and FRED X devices for unruptured aneurysms between 2013 and 2023 at 3 neurovascular centers were retrospectively reviewed.
Intrasaccular flow disruption with the Woven Endobridge (WEB) has become a well-established endovascular technique for the treatment of intracranial aneurysms. This study presents our 12-year experience with the WEB and evaluates its evolving indications, procedures, and outcomes. A consecutive series of 324 aneurysms treated with WEB between 2011 and 2023 at three neurovascular centers was retrospectively analyzed and the study group was divided into four treatment periods.
View Article and Find Full Text PDFBackground: Only a few adolescents are meeting their daily vegetable requirement. At the same time, spicy food is increasingly popular and familiar across cultures.
Objectives: To explore the implementation of spicy vegetables into school meals, the primary objective is to determine adolescents' preferred degree of hot spice on steamed broccoli.
Background And Purpose: The Pipeline Embolization Device is a safe and effective treatment option for intracranial aneurysms. The newer Pipeline generations have received structural refinements and a surface modification to improve deliverability, procedural safety, and angiographic outcomes. This multicenter study evaluated the clinical safety and efficacy of the 2 surface-modified Pipeline iterations, Pipeline Vantage and Pipeline Flex with Shield Technology (PFS).
View Article and Find Full Text PDFDiabetes Res Clin Pract
August 2024
Aims: To assess the rate of diabetic retinopathy (DR) progression in an Australian cohort and to identify the determinants of DR progression in pregnancy.
Methods: A total of 367 pregnancies of women with Type 1 or 2 diabetes mellitus attending King Edward Memorial Hospital, Western Australia, between June 2020 and July 2023 were included. These women were screened for the presence and severity of DR in the first trimester and/or at 28-32 weeks gestation via retinal imaging with a DRS camera.
Purpose: The WEB 17 system represents the fifth generation of Woven Endobridge (WEB) flow disruptors and features a low profile with fewer wires than its predecessor, the WEB 21. The present study compares the safety and efficacy of the WEB 17 and WEB 21 for the treatment of unruptured cerebral aneurysms with 4-7 mm device sizes, which were available for both systems.
Methods: Patient and aneurysm characteristics, complications, clinical outcome and angiographic results were retrospectively analysed.
Objective: The flow re-direction endoluminal device (FRED) is a safe and effective treatment option for intracranial aneurysms. The novel FRED X features an antithrombotic surface coating ("X Technology") on an otherwise unmodified stent design. This two-center study evaluates the clinical safety and efficacy of FRED X and compares it to the literature.
View Article and Find Full Text PDFIntroduction: Restricted retinal diffusion (RDR) has recently been recognized as a frequent finding on standard diffusion-weighted imaging (DWI) in central retinal artery occlusion (CRAO). However, data on early DWI signal evolution are missing.
Patients And Methods: Consecutive CRAO patients with DWI performed within 24 h after onset of visual impairment were included in a bicentric, retrospective cross-sectional study.
The membrane-bound [NiFe]-hydrogenase of is a rare example of a truly O-tolerant hydrogenase. It catalyzes the oxidation of H into 2e and 2H in the presence of high O concentrations. This characteristic trait is intimately linked to the unique Cys[4Fe-3S] cluster located in the proximal position to the catalytic center and coordinated by six cysteine residues.
View Article and Find Full Text PDFObjective: Several studies have demonstrated a high safety and efficacy profile of the Woven EndoBridge (WEB) for endovascular aneurysm treatment. However, contemporary large-scale studies of the WEB are rare. This multicenter study attempts to set a benchmark for state-of-the-art WEB treatment with consistent application of the WEB oversizing technique.
View Article and Find Full Text PDFBackground: Occlusion of the internal carotid artery (ICA) may extend into the middle or anterior cerebral artery (ICA-T) or be confined to the intracranial (ICA-I) or extracranial segment (ICA-E). While there is excellent evidence for endovascular therapy (EVT) in ICA-T occlusions, studies on EVT in non-tandem ICA-I or ICA-E occlusions are scarce.
Objective: To characterize EVT-treated patients with ICA-I- and ICA-E occlusion by comparing them with ICA-T occlusions.
Introduction: In recent years, the role of intravenous thrombolysis (IVT) before endovascular stroke treatment (EVT) has been discussed intensively. Whether the discussion was accompanied by changing rates of bridging IVT is unknown.
Methods: Data were extracted from the prospectively maintained German Stroke Registry, including patients treated with EVT at one of 28 stroke centers in Germany between 2016 and 2021.
Background: Numerous questions regarding procedural details of distal stroke thrombectomy remain unanswered. This study assesses the effect of anesthetic strategies on procedural, clinical and safety outcomes following thrombectomy for distal medium vessel occlusions (DMVOs).
Methods: Patients with isolated DMVO stroke from the TOPMOST registry were analyzed with regard to anesthetic strategies (ie, conscious sedation (CS), local (LA) or general anesthesia (GA)).