Publications by authors named "Sidnei Oliveira Souza"

In this study, the use of hydride generation atomic fluorescence spectrometry (HG-AFS) coupled with the multi-syringe flow injection analysis (MSFIA) has been proposed in the application of the Doehlert design to optimise the determination of As and Sb in gouache and tempera children's paints. The determination of the total and bioavailable As and Sb in paint samples from various brands and colours was also investigated. The limits of quantification (LOQ) obtained for the determination of As and Sb were 14.

View Article and Find Full Text PDF

The fractional factorial and Doehlert designs for optimization of a slurry sampling procedure to determine of nutrients in sugarcane juice by inductively coupled plasma optical emission spectrometry (ICP OES) were applied. External calibration curves were used for direct analysis of the slurry. This procedure allowed determination of Ca, Cu, Fe, K and Mg with limits of detection (LoD) obtained of 2.

View Article and Find Full Text PDF

This work proposes the application of a Doehlert design to optimize dilute HNO and HO concentrations employed for the digestion of samples of modelling clay for children (used as toy). Inductively coupled plasma-based (ICP) methods were employed to determine 22 inorganic constituents (Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, P, Pb, S, Sb, Se, Sr, V and Zn) in children's modelling clay samples. The limits of quantification (LoQ) obtained were between 0.

View Article and Find Full Text PDF

This paper describes a method development for chlorine determination through the formation of MgCl molecule, applied for the first time for Cl quantification, by high resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS) in environmental samples. Pyrolysis and vaporization temperatures were optimized as well as the use of chemical modifier. Determinations were carried out at the wavelength of 377.

View Article and Find Full Text PDF

A full 24 factorial design was applied to find the best combination of diluted reagents (HNO3 and H2O2), time, and temperature for the digestion of samples of wet feed for dogs and cats using a closed digestion block. The residual carbon concentration (RCC) was used as the response in the factorial design. All variables and their interactions significantly influenced the digestion of the feed samples, as indicated by the RCC.

View Article and Find Full Text PDF