Publications by authors named "Shusuke Inukai"

Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.

View Article and Find Full Text PDF

The aim of this study was to investigate the effect of scanning origin location on the data accuracy of removable partial denture (RPD) abutment teeth region in digital impressions acquired by an intraoral scanner. A mandibular partially edentulous model including the following target abutment teeth was used: the left second molar (#37); left first premolar (#34); and right second premolar (#45). The following scanning strategies were tested: the strategy starting from #37 to mesial direction (37M); strategies starting from #34 to mesial (34M) and distal directions (34D), and strategies starting from #45 to mesial (45M) and distal directions (45D).

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the inhibitory effect of night denture (ND) placement on abutment tooth mobility in removable partial denture (RPD) wearers with sleep bruxism (SB).

Methods: The participants were selected from RPD wearers diagnosed with SB using BiteStrip® and randomly allocated to one of the following groups: with ND placement or without ND placement (intervention or control group, respectively). The mobility of the RPD abutment tooth was measured using Periotest® at baseline (T0) and at 1 (T1), 3 (T3), and 6 months (T6).

View Article and Find Full Text PDF

The aim of this study was to determine the utility of respiratory resistance as a predictor of oral appliance (OA) response in obstructive sleep apnea (OSA). Twenty-seven patients with OSA (mean respiratory event index (REI): 17.5 ± 6.

View Article and Find Full Text PDF

Background/objectives: Speech impairment during the initial phase of removable partial denture (RPD) treatment can prevent patient adaptation to RPDs. This quasi-experimental study aimed to investigate the influence of the covering area of major connectors located in the mandibular anterior region on the accuracy of speech production.

Methods: Fifteen adults (12 men and 3 women aged 26-40 years) with healthy dentition were recruited.

View Article and Find Full Text PDF

Background/aims: Speech impairment during the initial phase of removable partial denture (RPD) treatment can prevent patient adaptation to RPDs. This study was undertaken to investigate the influence of oral morphology on speech production in subjects wearing RPDs with major connectors.

Methods: Two types of connectors were fabricated for 17 subjects with normal dentitions: covering the middle palate (M-bar) and the anterior/posterior palate (AP-bar).

View Article and Find Full Text PDF

Purpose: There are no studies on the prevention of temporomandibular joint and/or masticatory muscle pain (TMD pain) associated with oral appliance (OA) therapy in patients with obstructive sleep apnea (OSA). The aim of this study was to determine the effect of jaw-opening exercise on TMD pain associated with OA therapy in OSA patients.

Methods: Twenty-five OSA patients without pain-related TMD were consecutively enrolled into a two-arm, randomized, double-blind, placebo-controlled trial.

View Article and Find Full Text PDF

Statement Of Problem: The optimum selection of denture teeth for patients with a reduced interarch distance has not been established.

Purpose: The purpose of this in vitro study was to investigate the influence of denture tooth material and thickness on the fracture resistance of thin acrylic resin denture bases.

Material And Methods: Acrylic resin (AC), composite resin (CO), or ceramic (CE) molar denture teeth were embedded in denture base blocks (2.

View Article and Find Full Text PDF

Objective: To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system.

Patients And Methods: Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki].

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the influence of the major connector in a maxillary denture.

Methods: Eight patients with sound dentition were recruited in this study. The experimental connectors were fabricated with Co-Cr.

View Article and Find Full Text PDF