Publications by authors named "Shuji Otsuki"

Background: The role of circulating progenitor cells (CPC) in vascular repair following everolimus-eluting stent (EES) implantation is largely unknown. The aim of the study was to investigate the relationship between temporal variation in CPC levels following EES implantation and the degree of peri-procedural vascular damage, and stent healing, as measured by optical coherence tomography (OCT).

Methods and results: CPC populations (CD133+/KDR+/CD45low) included patients with stable coronary artery disease undergoing stent implantation, and were evaluated using a flow cytometry technique both at baseline and at 1 week.

View Article and Find Full Text PDF

Background/purpose: To study the impact of diabetes mellitus (DM) on vascular healing process after implantation of everolimus-eluting stent (EES).

Methods/materials: Data from 3 prospective studies (HEAL-EES, REVER, and RESERVOIR), including patients with EES implantation and OCT follow-up, were merged. Differences in vascular healing process assessed by OCT were compared between DM and non-DM using generalized estimating equations.

View Article and Find Full Text PDF

Background/purpose: Everolimus-eluting stents (EES) are established as latest generation drug eluting stents. However, optical coherence tomography (OCT) assessment of neointimal distribution after EES implantation is lacking. We aimed to assess the longitudinal neointimal distribution pattern after EES implantation using OCT.

View Article and Find Full Text PDF

We aimed to compare the efficacy and safety of transcatheter aortic valve implantation (TAVI) using Edwards SAPIEN 3 (S3) valve and SAPIEN XT) in smaller anatomy. The new generation S3 TAVI device has been used worldwide; however, its efficacy and safety in smaller Asian anatomy remain unknown. Between February 2014 and March 2017, 166 consecutive patients (S3, 54; XT, 112) were treated with balloon-expandable TAVI in a single center and their outcomes were analyzed.

View Article and Find Full Text PDF

Background: Incomplete stent apposition (ISA) is related to stent thrombosis, which is a serious adverse event. We aim to assess the time-course of ISA after 2nd generation everolimus-eluting stent (EES) implantation.

Methods: In HEAL-EES study, we enrolled 36 patients who underwent percutaneous coronary intervention (PCI) with EES.

View Article and Find Full Text PDF

Purpose: Second-generation drug-eluting stent (DES) have shown a better safety and efficacy as compared to first generation DES due to an improved vascular healing process. This process has not been so far evaluated in vivo in an overtime fashion by optical coherent tomography (OCT). We sought to evaluate the vascular healing process after everolimus-eluting stent (EES) implantation at 6, 9 and 12months, by OCT.

View Article and Find Full Text PDF

Background: Bioresorbable scaffolds provide transient lumen support followed by complete resorption.

Objectives: This study examined whether very late scaffold thrombosis (VLScT) occurs when resorption is presumed to be nearly complete.

Methods: Patients with VLScT at 3 tertiary care centers underwent thrombus aspiration followed by optical coherence tomography (OCT).

View Article and Find Full Text PDF

Bioresorbable vascular scaffolds (BVS) represent a breakthrough technology for percutaneous coronary intervention (PCI). In this context, because of the unique properties of bioresorbable devices, ST-segment elevation myocardial infarction (STEMI) may represent the ideal scenario for BVS implantation. Consistently, 57% of physicians declare they currently use BVS in this group of patients.

View Article and Find Full Text PDF

Optical coherence tomography (OCT) is able to identify thrombus. We detect the frequency of thrombus inside the guiding catheter by OCT and its relationship with clinical and procedural factors. We screened 77 patients who underwent OCT pullbacks.

View Article and Find Full Text PDF

Primary percutaneous coronary intervention is the preferred reperfusion strategy for patients presenting with ST-segment elevation myocardial infarction (STEMI). First generation drug-eluting stents (DES), (sirolimus drug-eluting stents and paclitaxel drug-eluting stents), reduce the risk of restenosis and target vessel revascularization compared to bare metal stents. However, stent thrombosis emerged as a major safety concern with first generation DES.

View Article and Find Full Text PDF

Background: It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES.

View Article and Find Full Text PDF

Background: Coronary optical coherence tomography (OCT) enables virtual depiction of histological findings of in-stent restenotic tissue. The aim of this study was to investigate the microvessel proliferation within in-stent restenotic tissue and the influence of diabetes mellitus (DM).

Methods: We examined 54 in-stent restenotic coronary artery lesions (stenotic area>50%) from 50 consecutive patients including 28 with DM (56%) and 9 insulin-treated DM patients (18%); who underwent coronary time-domain OCT imaging with automatic pull back (1mm/s, 20 frames/s).

View Article and Find Full Text PDF

Aims: This study was performed to assess the differences in culprit plaque composition between patients with and without pre-infarction angina (PA) by using spectral analysis of intravascular ultrasound (IVUS) radiofrequency (RF) data.

Methods And Results: Of 57 patients consecutively admitted to our institution with acute myocardial infarction, pre-intervention IVUS RF data of culprit plaques were obtained and analysed in 35 patients after percutaneous aspiration thrombectomy. Among the 35 patients, 21 patients had PA.

View Article and Find Full Text PDF

Background: Percutaneous coronary intervention for hemodialysis patients has been hampered by the high rate of adverse cardiac events. Our aim was to investigate whether sirolimus-eluting stents (SESs) improve clinical outcomes of hemodialysis patients compared with bare-metal stents (BMSs).

Study Design: Retrospective study.

View Article and Find Full Text PDF

Background: The relationship between coronary artery remodeling and culprit plaque composition in vivo has not been fully evaluated by spectral analysis of intravascular ultrasound (IVUS) radiofrequency (RF) data.

Methods And Results: IVUS RF analyses were performed for 56 consecutive de novo culprit lesions of 52 patients undergoing percutaneous coronary intervention. Remodeling of culprit lesions was determined using the remodeling index (RI), calculated as the external elastic membrane area of the minimum lumen area (MLA) site divided by that of the proximal reference site.

View Article and Find Full Text PDF