Publications by authors named "Shoji Motomizu"

A new design of membraneless gas-diffusion unit with dual acceptor channels for separation, collection and simultaneous determination of two volatile analytes in liquid sample is presented. The unit is comprised of three parallel channels in a closed module. A sample is aspirated into the central channel and two kinds of reagents are introduced into the other two channels.

View Article and Find Full Text PDF

An advanced stopped-in-loop flow analysis (SILFA) is proposed for the catalytic determinations of vanadium and iron. The chemistry relies on a vanadium- or iron-catalyzed oxidative reaction of p-anisidine by bromate or hydrogen peroxide in the presence of an activator (Tiron or 1,10-phenanthlorine) to form a red dye (510 nm). Reagents for the vanadium- or iron-catalyzed reaction are well mixed by a reagents-merging zones technique.

View Article and Find Full Text PDF

A novel four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for successive determination of bilirubin and creatinine in urinary samples. The chemical variables and physical parameters in the flow system were optimized for the enhancement of successive analytical performances. The interferences from urine matrices on the determination of bilirubin and creatinine were eliminated to dilute urine samples.

View Article and Find Full Text PDF

The thermoacidophilic iron-oxidizing archaeon Acidianus brierleyi is a microorganism that could be useful in the removal of inorganic As from wastewater, because it simultaneously oxidizes As(III) and Fe(II) to As(V) and Fe(III) in an acidic culture medium, resulting in the immobilization of As(V) as FeAsO₄. To investigate the oxidation mechanism, speciation of the As species in both the cells and its culture media is an important issue. Here we describe the successive determination of As(III), As(V), and total As in A.

View Article and Find Full Text PDF

An automated method has been developed for determining the concentration of inorganic arsenic. The technique uses sequential injection/anodic stripping voltammetry with a long-lasting gold-modified screen-printed carbon electrode. The long-lasting gold electrode was electrochemically deposited onto a screen-printed carbon electrode at a potential of -0.

View Article and Find Full Text PDF

An environment friendly electrode for determining Cd(2+) and Pb(2+) levels in an automated flow system was successfully developed. Cyclic voltammetry and square wave anodic stripping voltammetry (SWASV) coupled with sequential injection analysis (SIA) were employed to study the electrochemical behavior of the electrode. The in situ bismuth-modified graphene-carbon paste electrode (Bi-GCPE) exhibited excellent electrooxidation of Cd(2+) and Pb(2+) in the automated flow system with a significantly higher peak current for both metal ions compared with the unmodified CPE.

View Article and Find Full Text PDF

The highly sensitive determination of lead (Pb(II)) and cadmium (Cd(II)) ions, with a limit of detection of 0.01μgL(-1) for Pb(II) and Cd(II), by on-line preconcentration and anodic stripping voltammetry (ASV) controlled by a sequential injection analysis (SIA) system is reported here. The SIA system consisted of a syringe pump, an 8-port selection valve and a 6-port switching valve and was incorporated with a bismuth coated screen-printed carbon nanotube electrode (Bi-SPCNTE).

View Article and Find Full Text PDF

A new four-channel simultaneous injection effective mixing flow analysis (SIEMA) system has been assembled for the determination of urinary albumin. The SIEMA system consisted of a syringe pump, two 5-way cross connectors, four holding coils, five 3-way solenoid valves, a 50-cm long mixing coil and a spectrophotometer. Tetrabromophenol blue anion (TBPB) in Triton X-100 micelle reacted with albumin at pH 3.

View Article and Find Full Text PDF

A low-cost thin-layer electrochemical flow-through cell based on a carbon paste electrode (CPE), was constructed for the highly sensitive determination of cadmium(II) (Cd(2+)) and lead(II) (Pb(2+)) ions. The sensitivity of the proposed cell for Cd(2+) and Pb(2+) ion detection was improved by using the smallest channel height without the need for any complicated electrode modification. Under the optimum conditions, the detection limits of Cd(2+) and Pb(2+) ions (0.

View Article and Find Full Text PDF

A novel simultaneous injection effective mixing analysis system (SIEMA) for determination of direct bilirubin in urine sample was developed. Bilirubin reacts with diazotized sulfanilic acid in the presence of n-octyl-β-d-thioglucoside (OTG) as a solubilizing agent to form OTG-azobilirubin. The flow and chemical variables were investigated.

View Article and Find Full Text PDF

A novel reagent, 2',7'-dichlorofluorescein di-tert-butyldimethylsilyl ether (FCl(2)TBS), was synthesized for fluoride ion and used for a sensitive fluorimetric flow injection analysis by detecting the recovery of fluorescence due to cleavage of Si-O bond. Four kinds of fluorescein di-tert-butyldimethylsilyl ether (FTBS) analogues were synthesized and FCl(2)TBS was the best. By introducing chlorine to FTBS, stability of the reagent, reactivity and the baseline signals were improved.

View Article and Find Full Text PDF

Flow-injection analysis system (FIA system), which was based on Fe(II)-catalyzed oxidation of chromotropic acid with hydrogen peroxide, was developed for the determination of hydrogen peroxide. The chromotropic acid has a fluorescence measured at lambda(em)=440 nm (emission wavelength) with lambda(ex)=235 nm (excitation wavelength), and the fluorescence intensity at lambda(em)=440 nm quietly decreased in the presence of hydrogen peroxide and Fe(II), which was caused by Fe(II)-catalyzed oxidation of chromotropic acid with hydrogen peroxide. By measuring the difference of fluorescence intensity, hydrogen peroxide (1.

View Article and Find Full Text PDF

The binding equilibrium of N-alkylpyridinium ions to nonionic surfactant micelles was investigated through the changes in the electrophoretic mobility of the alkylpyridinium ions in capillary zone electrophoresis. The binding constants thus determined increased with increasing molecular volume of the alkylpyridinium ions. However, the binding constants are small compared with the ones for the anionic alkylbenzenesulfonate and polynitrophenolate ions at the same molecular volume.

View Article and Find Full Text PDF

A fully automated pretreatment system based on sequential injection solid-phase extraction (SPE) coupled to a graphite furnace atomic absorption spectrometer (Auto-Pret-GFAAS system) was developed to determine trace amounts of cadmium and lead. A handmade minicolumn packed with a chelating resin was used for the preconcentration of both metals. All protocol for the on-line SPE method was controlled by home-made software.

View Article and Find Full Text PDF

A method for the simultaneous determination of Pb(II), Cd(II), and Zn(II) at low microg L(-1) concentration levels by sequential injection analysis-anodic stripping voltammetry (SIA-ASV) using screen-printed carbon nanotubes electrodes (SPCNTE) was developed. A bismuth film was prepared by in situ plating of bismuth on the screen-printed carbon nanotubes electrode. Operational parameters such as ratio of carbon nanotubes to carbon ink, bismuth concentration, deposition time and flow rate during preconcentration step were optimized.

View Article and Find Full Text PDF

This work presents a flow analysis method for direct quantitation of calcium carbonate in cement without pretreatment of the sample. The method is based on online vaporization of CO(2) gas following acidification of the sample inside a small chamber that has a flow of acceptor solution passing around it. Solubilization of the CO(2) gas into the acceptor stream changes the conductivity of the acceptor solution causing an increase of signal at the capacitively coupled contactless conductivity detection (C(4)D) placed at the outlet of the vaporization chamber.

View Article and Find Full Text PDF

A novel concept of simultaneous injection-effective mixing analysis (SIEMA) is proposed, and a SIEMA method applied to the spectrophotometric determination of palladium using a water-soluble chromogenic reagent has been demonstrated. The flow configuration of SIEMA is a hybrid format of flow injection analysis (FIA), sequential injection analysis (SIA) and multicommutation in flow-based analysis. Sample and reagent solutions are aspirated into each holding coil through each solenoid valve by a syringe pump, and then the zones are simultaneously dispensed (injected) into a mixing coil by reversed flow toward a detector through a confluence point.

View Article and Find Full Text PDF

High-capacity chitosan-based chelating resin, N-(2-hydroxyethyl)glycine-type chitosan, was synthesized using chloromethyloxirane (CMO) as a cross-linker and a coupling arms and hydroxylethylamine and bromoacetic acid as a synthesizer for the N-(2-hydroxyethyl)glycine chelating moiety. The CMO could bind with both of hydroxyl and amino group of the chitosan resin, and then couple with the chelating moiety. Increasing the amounts of chelating moiety could increase the capacity of the resin toward metal ions.

View Article and Find Full Text PDF

Catalytic effect of metal ions on luminol chemiluminescence (CL) was investigated by sequential injection analysis (SIA). The SIA system was set up with two solenoid micropumps, an eight-port selection valve, and a photosensor module with a fountain-type chemiluminescence cell. The SIA system was controlled and the CL signals were collected by a LabVIEW program.

View Article and Find Full Text PDF

Two vitamin C species of ascorbic acid and dehydroascorbic acid in aqueous solution were monitored by flow injection analysis. Ascorbic acid and dehydroascorbic acid were resolved by a reversed-phase column, and dehydroascorbic acid was reduced to ascorbic acid by an on-line post-column reaction with dithiothreitol. Both natural and reduced ascorbic acids were photometrically detected at 260 nm, and the two vitamin C species were simultaneously determined.

View Article and Find Full Text PDF

Cross-linked chitosan resins with catechol (catechol-type chitosan, type 1 and type 2), iminodiacetic acid (IDA-type chitosan), iminodimetylphosphonic acid (IDP-type chitosan), phenylarsonic acid (phenylarsonic acid-type chitosan), or serine (serine-type chitosan) were prepared for the collection and concentration of uranium(VI). The adsorption behavior of U(VI) and other ionic species, such as metal ions and oxo-acid ions, on the cross-linked chitosan (base material) and chitosan resins modified with chelating moieties was examined using a column procedure. Especially, the catechol-type chitosan (type 2) adsorbed U(VI) at pH 2-7, and selectively collected U(VI) at acidic pH regions by forming a stable chelate with hydroxyl groups of catechol moiety introduced to the chitosan.

View Article and Find Full Text PDF

The application of inductively coupled plasma atomic emission spectrometry (ICP-AES) to the forensic sample was studied. On-line collection/concentration method of the sample with chelating resin column (TE-05) and air-sandwiched method to isolate the analyte zone at the highest concentration of an eluent was coupled with ICP-AES. The limits of detection (LODs) were much improved to 35 fold (Co): from Sc, 0.

View Article and Find Full Text PDF

A novel chitosan resin, cross-linked chitosan functionalized with histidine moiety (histidine-type chitosan resin), was synthesized for the collection and concentration of trace silver in aquatic samples. A triplet automated-pretreatment system (Triplet Auto-Pret System) installed mini-columns packed with the synthesized histidine-type chitosan resin was coupled with an inductively coupled plasma-atomic emission spectrometry (ICP-AES) for a rapid and sensitive analysis. Adsorption behavior of 50 elements on the histidine-type chitosan resin was examined.

View Article and Find Full Text PDF