J Photochem Photobiol B
January 2020
Fluorescence dynamics of human d-amino acid oxidase (hDAAO) and its five inhibitors have been studied in the picoseconds time domain, and compared with one in d-amino acid oxidase from porcine kidney (pkDAAO) reported. The fluorescence lifetimes were identified as 47 ps in the dimer, 235 ps in the monomer, which are compared with those of pkDAAO (45 ps-185 ps). The fluorescence lifetimes of the hDAAO did not change upon the inhibitor bindings despite of modifications in the absorption spectra.
View Article and Find Full Text PDFBackground: Ultrasound (US)-guided transversus abdominis plane (TAP) block is widely-spread analgesic technique for the patients undergoing abdominal surgery and can be provided safely for the patients receiving anticoagulation therapy. We conducted a retrospective comparative trial of analgesic efficacy between the patient who received US-guided TAP block with postoperative continuous iv-fentanyl infusion (group T) and those who received epidural analgesia (group E).
Methods: Twenty three patients who had undergone abdominal aortic replacement were analyzed retrospectively.
Background: We encountered markedly elevated procalcitonin (PCT) among pediatric patients during the early postoperative period of open heart surgery. The purpose of this study is to investigate what factors are associated with the PCT elevation.
Methods: Fifty-two pediatric patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) were enrolled.
A woman with complex regional pain syndrome (CRPS) in the right lower extremity who wished to discontinue medications to get pregnant underwent implantation of a spinal cord stimulation system (SCS). An electrode lead was placed at Th(10-11) in the epidural space, accessed via the L(2-3) interspace with a paramedian approach, and a pulse generator was implanted in the left buttock. She kept the SCS on 24 h a day.
View Article and Find Full Text PDFIn-depth investigation of cerebrovascular blood flow and MR mechanisms underlying the blood oxygenation level dependent signal requires precise manipulation of the arterial partial pressure of carbon dioxide and oxygen, measured by their noninvasive surrogates, the end-tidal values. The traditional methodology consists of administering a fixed fractional concentration of inspired CO(2), but this causes a variable ventilatory response across subjects, resulting in different values of end-tidal partial pressures of CO(2) and O(2). In this study, we investigated whether fine control of these end-tidal partial pressures would improve stability and predictability of blood oxygenation level dependent and arterial spin labeling signals for studying cerebrovascular reactivity.
View Article and Find Full Text PDFBackground: Internal jugular vein (IJV) catheterization in pediatric patients is sometimes difficult because of the small sizes of veins and their collapse during catheterization. To facilitate IJV catheterization, we developed a novel skin-traction method (STM), in which the point of puncture of the skin over the IJV is stretched upward with tape during catheterization. In this study, we examined whether the STM increases the cross-sectional area of the vein and thus facilitates catheterization.
View Article and Find Full Text PDFPurpose: We aimed to introduce a simple, lightweight continuous positive airway pressure (CPAP)-delivery device for the nondependent lung during one-lung ventilation, to investigate how the type of three-way stopcocks, and the compliance and resistance of a test lung affect the relationship between the oxygen flow rate and CPAP level produced, and to examine how the device works in a clinical setting.
Methods: In the test lung study, the bronchial blocker of a Univent tube was connected to a test lung. The effects of oxygen-flow rate, types of three-way stopcocks, and compliance and resistance of the test lung on the CPAP levels were studied.
Purpose: Real-time ultrasound-assisted guidance for catheterization of the internal jugular vein (IJV) is known to be useful, especially for a small-sized vein, which is difficult to catheterize. However, one of the problems with real-time ultrasound-assisted guidance is that the ultrasound probe itself can collapse the vein. We have developed a novel "skintraction method (STM)", in which the puncture point of the skin over the IJV is stretched upwards with several pieces of surgical tape in the cephalad and caudal directions with the aim being to facilitate catheterization of the IJV.
View Article and Find Full Text PDFAccurate measurements of arterial P(CO(2)) (P(a,CO(2))) currently require blood sampling because the end-tidal P(CO(2)) (P(ET,CO(2))) of the expired gas often does not accurately reflect the mean alveolar P(CO(2)) and P(a,CO(2)). Differences between P(ET,CO(2)) and P(a,CO(2)) result from regional inhomogeneities in perfusion and gas exchange. We hypothesized that breathing via a sequential gas delivery circuit would reduce these inhomogeneities sufficiently to allow accurate prediction of P(a,CO(2)) from P(ET,CO(2)).
View Article and Find Full Text PDFThe study of the biology of evolution has been confined to laboratories and model organisms. However, controlled laboratory conditions are unlikely to model variations in environments that influence selection in wild populations. Thus, the study of "fitness" for survival and the genetics that influence this are best carried out in the field and in matching environments.
View Article and Find Full Text PDFThe aim of this study was to test our hypothesis that both phasic cardiac vagal activity and tonic pulmonary vagal activity, estimated as respiratory sinus arrhythmia (RSA) and anatomical dead space volume, respectively, contribute to improve the efficiency of pulmonary gas exchange in humans. We examined the effect of blocking vagal nerve activity with atropine on pulmonary gas exchange. Ten healthy volunteers inhaled hypoxic gas with constant tidal volume and respiratory frequency through a respiratory circuit with a respiratory analyser.
View Article and Find Full Text PDFPulmonary capillary blood flow (PCBF), anatomical dead space (VDaw) and SpO2 were measured and recorded continuously using NICO (Novametrix Medical Systems Inc, USA) in 2 cases during pulmonary resection under one-lung ventilation (OLV). A pulmonary artery catheter was inserted and continuous CO (CCO) was also measured in case 2. In both cases PCBF decreased by half when one lung was blocked.
View Article and Find Full Text PDFThe transradial approach for coronary catheterization is now a routine technique without serious complications at the puncture site. We report a case of complex regional pain syndrome type II (CRPS type II) in the hand after the transradial coronary intervention, which may alert medical personnel that the technique may cause serious regional pain with disability. A 61-year-old woman underwent coronary intervention via the right radial artery for the treatment of unstable angina.
View Article and Find Full Text PDFSelf-oscillation of polymer chains in an aqueous solution has been achieved. The ruthenium catalyst for the Belousov-Zhabotinsky reaction was polymerized by using N-isopropylacrylamide and dissolved into the solution containing the BZ substrates. Periodical soluble-insoluble changes of the polymer chain were spontaneously induced by the BZ reaction.
View Article and Find Full Text PDFThe nucleophilic addition reaction of a pyrrole nitrogen of free-base porphyrins to a pi-complexed acetylene ligand in a cationic Co(III) porphyrin intermediate afforded good yields of vinylene-Co,N'-linked bis(porphyrin)s, (Por)Co(III)-CH=CH-(N-Por)H(2). N-substituted porphyrin free bases are N-vinylated regioselectively at the pyrrole adjacent to the original N-substituted pyrrole in this reaction. Tris- and tetrakis(porphyrin)s have been prepared by reacting a vinylene-N,N'-linked bis(meso-tetraarylporphyrin) with (OEP)Co(III)(H(2)O)(2)ClO(4) (OEP: octaethylporphyrin dianion) and acetylene.
View Article and Find Full Text PDF