Publications by authors named "Shiva Sale"

Article Synopsis
  • The procedure aimed to replace a previous composite graft with a bioprosthesis using advanced surgical techniques involving cannulation and cardiopulmonary bypass for controlled hypothermia.
  • The surgical team entered the pseudoaneurysm, carefully dividing the old graft and preparing for the attachment of a new graft while managing circulation pauses.
  • Finally, they replaced the aortic root with a new bioprosthetic valved conduit and re-implanted the coronary arteries into the new graft.
View Article and Find Full Text PDF

Context: Global longitudinal strain (GLS) measured by speckle-tracking echocardiography demonstrates excellent prognostic ability in predicting major adverse cardiac events after cardiac surgery. However, the optimal timing of intraoperative GLS measurement that provides the best prognostic value is unclear.

Aim: Our goal was to evaluate whether GLS measured prior to cardiopulmonary bypass (pre-CPB GLS), following CPB (post-CPB GLS), or change in GLS provides the strongest association with postoperative complications.

View Article and Find Full Text PDF

We examined whether intraoperative assessment of left ventricular (LV) twist mechanics is feasible with transesophageal echocardiography (TEE). We then explored whether twist mechanics were altered by hemodynamic conditions or patient comorbidities. In this sub-analysis of clinical trial data, transgastric short-axis echocardiographic images of the LV base and apex were collected in patients having aortic valve replacement (AVR) at baseline and end of surgery.

View Article and Find Full Text PDF

Objectives: To examine E-aminocaproic acid effectiveness in reducing transfusion requirements in overall and less-invasive cardiac surgery, and to assess its safety.

Design: Retrospective cohort study.

Setting: Single-center tertiary academic medical center.

View Article and Find Full Text PDF

Background: The VentriFlo True Pulse Pump (VentriFlo, Inc, Pelham, NH, USA) is a new pulsatile blood pump intended for use during short-term circulatory support. The purpose of this study was to evaluate the feasibility of the VentriFlo and compare it to a conventional centrifugal pump (ROTAFLOW, Getinge, Gothenberg, Sweden) in acute pig experiments.

Methods: Pigs (40-45 kg) were supported by cardiopulmonary bypass (CPB) with the VentriFlo (n = 9) or ROTAFLOW (n = 5) for 6 h.

View Article and Find Full Text PDF

Objective: To evaluate the effect of autologous whole blood (AWB) collection on intraoperative/postoperative allogeneic blood transfusion rate in complex aortic surgery with hypothermic circulatory arrest.

Methods: This retrospective study included adults who underwent aortic surgery with hypothermic circulatory arrest at a single institution between 2014 and 2019. Out of 509 cases (414 patients), 110 (22%) received the AWB protocol.

View Article and Find Full Text PDF
Article Synopsis
  • Monitored anesthesia care (MAC) is increasingly favored over general anesthesia (GA) for transcatheter aortic valve replacement (TAVR), reducing complications and improving efficiency.
  • In a study involving 998 patients, those receiving MAC exhibited significantly shorter procedural and fluoroscopy times, lower contrast volume, and reduced radiation exposure, alongside quicker recovery times and higher discharge rates to home.
  • While MAC showed lower 30-day mortality compared to GA, there were no significant differences in long-term mortality or major adverse cardiac events, indicating MAC’s safety and effectiveness with newer valve technologies.
View Article and Find Full Text PDF

Background: The Advanced ventricular assist device (Advanced VAD) is designed as a universal pump intended to prevent backflow in the event of pump stoppage, to maintain physiological pulse pressure, and to be used as both a left and right VAD. The purpose of this study was to evaluate the performance of the Advanced VAD as both a left and right VAD in an acute in vivo study in calves.

Methods: The Advanced VAD was implanted through a median sternotomy in 5 healthy calves (weight, 71.

View Article and Find Full Text PDF

Biventricular assist device (BVAD) implantation is the treatment of choice in patients with severe biventricular heart failure and cardiogenic shock. Our team has developed a miniaturized continuous flow, double-ended centrifugal pump intended for total artificial heart implant (CFTAH). The purpose of this initial in vivo study was to demonstrate that the scaled-down CFTAH (P-CFTAH) can be appropriate for BVAD support.

View Article and Find Full Text PDF

Objectives: Right ventricular failure after left ventricular assist device implantation increases postoperative morbidity and mortality. Whether intraoperative echocardiographic and hemodynamic measurements predict right ventricular failure is unclear. Speckle-tracking-derived tricuspid annulus displacement may provide a useful, effective, and straightforward predictor of severe right ventricular failure in patients having left ventricular device implantation.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to compare patient outcomes between those treated with inhaled epoprostenol (iEpo) and low tidal volume ventilation during cardiopulmonary bypass and those who did not receive the medication at all or only received it as a rescue therapy.
  • A retrospective chart review involved 71 patients, predominantly male (78.9%), undergoing various cardiac procedures, revealing significant differences in postoperative complications between groups.
  • Results showed that patients treated with iEpo had higher rates of open chest after surgery and longer mechanical ventilation duration compared to the control group, suggesting the use of iEpo as a preventive measure could lead to better outcomes than using it as a last resort.
View Article and Find Full Text PDF

This study aimed to evaluate the effects of posture (sitting [lying down]/standing) on hemodynamic and pump-related parameters in calves implanted with our institution's continuous-flow total artificial heart (CFTAH). These parameters were analyzed with posture information in four calves that had achieved the intended 14-, 30-, or 90-day durations of implantation. In each animal, postoperative hourly data gathered throughout the study were used to compare average values with the animal sitting vs.

View Article and Find Full Text PDF

Objective: Myocardial strain measured by speckle-tracking echocardiography detects subtle regional and global left ventricular dysfunction. Myocardial strain is measured in the longitudinal, circumferential, and radial dimensions; however, it is unclear which dimension of strain is the best predictor of postoperative outcomes.

Design: A secondary analysis of prospectively collected data from a clinical trial (NCT01187329).

View Article and Find Full Text PDF

With increasing use of cardiovascular implantable electronic devices, the need for lead extractions has increased to an annual volume of more than 10,000 extractions worldwide. This article provides a focused clinical commentary on the perioperative management, identification, and treatment of life-threatening complications associated with lead extractions. In addition, a summary of indications, techniques, and lead extraction complications is provided.

View Article and Find Full Text PDF

Background: Left ventricular ejection fraction (LVEF) is often preserved in patients with aortic stenosis and thus cannot distinguish between normal myocardial contractile function and subclinical dysfunction. Global longitudinal strain and strain rate (SR), which measure myocardial deformation, are robust indicators of myocardial function and can detect subtle myocardial dysfunction that is not apparent with conventional echocardiographic measures. Strain and SR may better predict postoperative outcomes than LVEF.

View Article and Find Full Text PDF

The VentriFlo True Pulse Pump (Design Mentor, Inc., Pelham, NH, USA) is the first blood pump designed to mimic human arterial waveforms in a standard oxygenation circuit. Our aim was to demonstrate the feasibility and safety of this pump in preparation for future studies to determine possible clinical advantages.

View Article and Find Full Text PDF

Redo cardiac surgery in patients with severe aortic insufficiency can present unique challenges to the anesthesiologist. We report a case highlighting the challenge and importance of interdisciplinary planning between cardiothoracic surgeons and anesthesiologists prior to high-risk surgery. Failure to place an endoaortic balloon and percutaneous coronary sinus catheter due to anatomical abnormalities prompted the adoption of an alternate technique involving apical ventricular venting to assist sternal reentry.

View Article and Find Full Text PDF

Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs.

View Article and Find Full Text PDF