Despite the importance of T-weighted image in clinical practice, artifacts can significantly degrade image quality and affect diagnosis. This study quantitatively analyzed uterine displacement and surveyed the relationship between the image quality of fast-spin-echo-T-weighted image of the female pelvis and quantitative value of uterine displacement. Overall, 147 women (mean age, 46.
View Article and Find Full Text PDFObjectives: To investigate the relationship between conventionally obtained serum-based biochemical indices and intravoxel incoherent motion imaging (IVIM) parameters compared with magnetic resonance elastography (MRE).
Methods: Patients with hepatocellular carcinoma who underwent ≥2 liver magnetic resonance imaging (MRI) scan, including IVIM and MRE, between 2017 and 2020 and biochemical testing within 1 week before or after MRI were included in this study. Biochemical tests were performed to determine the albumin-bilirubin (ALBI) score and modified ALBI (mALBI) grade, aspartate aminotransferase to platelet ratio index (APRI), and fibrosis-4 index (FIB-4).
Background: Previous studies have shown that the Valsalva maneuver (VM) causes spinal canal object movements. We hypothesized that this occurs because of cerebrospinal fluid (CSF) flow generated from intradural space reduction. Previous studies using myelograms reported lumbar CSF space changes during inspiration.
View Article and Find Full Text PDFObjective: To confirm the relationship between lumbar spinal stenosis (LSS) and cauda equina movement during the Valsalva maneuver.
Materials And Methods: Two radiologists at our institution independently evaluated cauda equina movement on pelvic cine MRI, which was performed for urethrorrhea after prostatectomy or pelvic prolapse in 105 patients (99 males; mean age: 69.0 [range: 50-78] years), who also underwent abdominopelvic CT within 2 years before or after the MRI.
Myocardial T1 mapping is a useful technique for the diagnosis of diffuse fibrosis. Although modified look-locker inversion recovery is a widely used T1 mapping method, variation in T1 values has been reported. Non-uniform T1 maps may hinder differentiation between healthy and diseased myocardial tissue.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
May 2018
The aim of this study was to evaluate the measurement precision and accuracy of T mapping using a polarity corrected (PC) TI prep tool, which was based on fast field echo (FFE) and obtained one data point with one inversion recovery (IR) pulse. A phantom was used consisting of eight materials with different Gd concentrations. T mappings were measured by changing the trigger interval and the inversion time (TI) interval.
View Article and Find Full Text PDFThe purpose of this study was to evaluate the magnetization and demagnetization of magnetic dental attachments in a 3.0-T magnetic resonance imaging (MRI) scanner. A high-field-strength (3.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
August 2016
In magnetic resonance imaging (MRI) examination of the patients with the cochlear implant, only limited data have a mention for safety information in the instruction manual supplied by the manufacturers. Therefore, imaging operators require more detailed safety information for implant device. We conducted detailed examination about displacement force, torque, and demagnetizing of the cochlear implant magnet based on American Society for Testing and Materials (ASTM) standard using the PULSAR and CONCERTO (MED-EL) with 1.
View Article and Find Full Text PDFNihon Hoshasen Gijutsu Gakkai Zasshi
March 2014
A questionnaire comprising 14 items, inquiring about the state of damage, whether safety could be ensured, and progress of repair and restoration was distributed to 984 facilities in seven prefectures on the Pacific coast as part of a fact-finding survey of damage caused to magnetic resonance (MR) devices by the Great East Japan Earthquake. In all, 458 responses (46.6%) were collected.
View Article and Find Full Text PDF