Publications by authors named "Shinsuke Yano"

Purpose: To investigate the effects of interfractional variation, such as anatomical changes and setup errors, on dose delivery during treatment for prostate cancer (PC) and head and neck cancer (HNC) by courses of volumetric modulated arc therapy (VMAT) aided by on-treatment electronic portal imaging device (EPID) images.

Methods: Seven patients with PC and 20 patients with HNC who had received VMAT participated in this study. After obtaining photon fluence at the position of the EPID for each treatment arc from on-treatment integrated EPID images, we calculated the differences between the fluence for the first fraction and each subsequent fraction for each arc.

View Article and Find Full Text PDF

This study aimed to obtain details regarding treatment planning techniques for lung stereotactic body radiation therapy (SBRT) employed at each institution in Japan by using a questionnaire survey. An Internet questionnaire survey on SBRT procedures performed in 2016 was conducted by the QA/QC committee of the Japan Society of Medical Physics from April to June 2017. The questionnaire assessed two aspects: the environment for SBRT at each institution and the treatment planning techniques with and without respiratory motion management techniques (RMMT).

View Article and Find Full Text PDF

This study investigated the effects of respiratory motion, including unwanted breath holding, on the target volume and centroid position on four-dimensional computed tomography (4DCT) imaging. Cine 4DCT images were reconstructed based on a time-based sorting algorithm, and helical 4DCT images were reconstructed based on both the time-based sorting algorithm and an amplitude-based sorting algorithm. A spherical object 20 mm in diameter was moved according to several simulated respiratory motions, with a motion period of 4.

View Article and Find Full Text PDF

Esophageal cancer rarely coincides with pregnancy, and only five cases have been reported thus far. The management of esophageal cancer during pregnancy is extremely challenging due to its aggressive nature. We herein report a case of recurrent esophageal cancer in pregnancy.

View Article and Find Full Text PDF

Intensity-modulated radiotherapy (IMRT) is now regarded as an important treatment option for patients with locally advanced pancreatic cancer (LAPC). To reduce the underlying tumor motions and dosimetric errors during IMRT as well as the burden of respiratory management for patients, we started to apply a new treatment platform of the dynamic tumor dynamic tumor-tracking intensity-modulated radiotherapy (DTT-IMRT) using the gimbaled linac, which can swing IMRT toward the real-time tumor position under patients' voluntary breathing. Between June 2013 and March 2015, ten patients were treated, and the tumor-tracking accuracy and the practical benefits were evaluated.

View Article and Find Full Text PDF
Article Synopsis
  • The purpose of the study was to verify the accuracy of lung stereotactic body radiotherapy (SBRT) plans using a secondary treatment planning system (TPS) and to establish tolerance levels between the primary and secondary TPSs.
  • The research involved recalculating dose distributions from 147 lung SBRT plans using two different algorithms (Acuros XB and anisotropic analytical algorithm) to compare results against a primary method (X-ray voxel Monte Carlo).
  • Results showed that the Acuros XB values closely matched those of the primary method within a 3.5% margin, while the anisotropic analytical algorithm tended to overestimate doses, indicating that Acuros XB is a more reliable tool for independent verification of dosimetric calculations.
View Article and Find Full Text PDF

Purpose: We evaluated three-dimensional intrafractional target motion, divided into respiratory-induced motion and baseline drift, in accelerated partial breast irradiation (APBI).

Methods: Paired fluoroscopic images were acquired simultaneously using orthogonal kV X-ray imaging systems at pre- and post-treatment for 23 patients who underwent APBI with external beam radiotherapy. The internal target motion was calculated from the surgical clips placed around the tumour cavity.

View Article and Find Full Text PDF

In external radiotherapy, the X-ray beam passes through the treatment couch, leading to the dose reduction by the attenuation of the couch. As a method to compensate for the reduction, radiation treatment planning systems (RTPS) support virtual couch function, namely "couch modeling method". In the couch modeling method, the computed tomography (CT) numbers assigned to each structure should be optimized by comparing calculations to measurements for accurate dose calculation.

View Article and Find Full Text PDF

It is generally known that the dose distribution around the high-density materials is not accurate with commercially available radiation treatment planning systems (RTPS). Recently, Acuros XB (AXB) has been clinically available for dose calculation algorithm. The AXB is based on the linear Boltzmann transport equation - the governing equation - that describes the distribution of radiation particles resulting from their interactions with matter.

View Article and Find Full Text PDF

We assessed interfraction positional variation in pancreatic tumors using daily breath-hold cone-beam computed tomography at end-exhalation (EE) with visual feedback (BH-CBCT). Eleven consecutive patients with pancreatic cancer who underwent BH intensity-modulated radiation therapy with visual feedback were enrolled. All participating patients stopped oral intake, with the exception of drugs and water, for > 3 hr before treatment planning and daily treatment.

View Article and Find Full Text PDF

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during "simultaneous integrated boost intensity-modulated radiotherapy" (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.

View Article and Find Full Text PDF

Purpose: To evaluate feasibility and acute toxicities after dynamic tumour tracking (DTT) irradiation with real-time monitoring for lung tumours using a gimbal mounted linac.

Materials And Methods: Spherical gold markers were placed around the tumour using a bronchoscope prior to treatment planning. Prescription dose at the isocentre was 56 Gy in 4 fractions for T2a lung cancer and metastatic tumour, and 48 Gy in 4 fractions for the others.

View Article and Find Full Text PDF

In electron radiotherapy, shielding material is required to attenuate beam and scatter. A newly introduced shielding material, tungsten functional paper (TFP), has been anticipated to become a very useful device that is lead-free, light, flexible, and easily processed, containing very fine tungsten powder at as much as 80% by weight. The purpose of this study was to investigate the dosimetric changes due to TFP shielding for electron beams.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the accuracy of using surgical clips for positional verification during accelerated partial breast irradiation treatment.
  • Preliminary phantom experiments determined that a computed tomography (CT) slice thickness of 2.5 mm was effective for detecting clips in imaging.
  • In clinical trials with 12 patients, 91% of clips were successfully included in the specified 5-mm region of interest, but significant displacement of clips was observed between treatment sessions.
View Article and Find Full Text PDF

Purpose: To verify the intrafractional tracking accuracy in infrared (IR) marker-based hybrid dynamic tumour tracking irradiation ("IR Tracking") with the Vero4DRT.

Materials And Methods: The gimballed X-ray head tracks a moving target by predicting its future position from displacements of IR markers in real-time. Ten lung cancer patients who underwent IR Tracking were enrolled.

View Article and Find Full Text PDF

Purpose: To assess the effect of abdominal compression on the interfraction variation in tumor position in lung stereotactic body radiotherapy (SBRT) using cone-beam computed tomography (CBCT) in a larger series of patients with large tumor motion amplitude.

Methods: Thirty patients with lung tumor motion exceeding 8 mm who underwent SBRT were included in this study. After translational and rotational initial setup error was corrected based on bone anatomy, CBCT images were acquired for each fraction.

View Article and Find Full Text PDF

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos⁶ (t) with a constant respiration period of 4.

View Article and Find Full Text PDF

The delivered dose of high-energy photon beams is measured with radiochromic film. Previous studies sought to improve the system sensitivity of radiochromic film dosimetry by use of band-pass filters. However, band-pass filters reduce the scanning light intensity.

View Article and Find Full Text PDF

Since stereotactic body radiotherapy (SBRT) was started for patients with lung tumor in 1998 in our institution, x-ray fluoroscopic examination and slow computed tomography (CT) scan with a rotation time of 4 s have been routinely applied to determine target volumes. When lung tumor motion observed with x-ray fluoroscopy is larger than 8 mm, diaphragm control (DC) is used to reduce tumor motion during respiration. After the installation of a four-dimensional (4D) CT scanner in 2006, 4D CT images have been supplementarily acquired to determine target volumes.

View Article and Find Full Text PDF

Purpose: Since 1998, we have treated primary and oligometastatic lung tumors with stereotactic body radiotherapy (SBRT). The term "oligometastasis" is used to indicate a small number of metastases limited to an organ. We evaluated our clinical experience of SBRT for oligometastatic lung tumors.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to verify a strategy for reducing systematic errors in prostate cancer treatment using a computer simulation of position errors during IMRT with a prone fixation device.
  • Researchers simulated an off-line correction method, analyzing portal images from early treatment sessions to determine the optimal number of images needed to minimize setup errors.
  • Results showed that increasing the number of images significantly reduced systematic errors, highlighting a notable impact when random errors were substantial.
View Article and Find Full Text PDF

GafChromic EBT film (GC-EBT) is lower in sensitivity than ready-pack film. The purpose of this study was to increase GC-EBT sensitivity by using band-pass filters and a polarized light filter. The filters were inserted between the GC-EBT and the scanner bed and digitized.

View Article and Find Full Text PDF

Stereotactic radiotherapy (SRT) for extracranial tumors has been recently performed to treat lung and liver cancers, and has subsequently been named stereotactic body radiotherapy (SBRT). The advantages of hypofractionated radiotherapy for treating lung tumors are a shortened treatment course that requires fewer trips to the clinic than a conventional program, and the adoption of a smaller irradiated volume allowed by greater setup precision. This treatment is possible because the lung and liver are considered parallel organs at risk.

View Article and Find Full Text PDF

The techniques of three-dimensional conformal radiotherapy (3 D-CRT) and patient immobilization have recently been developed, enabling us to focus high doses on the target with relatively less irradiation of normal tissues. In radiotherapy for solitary lung tumors, the local control may be safely improved by delivering a higher dose at only the target volume using these techniques. Recently, several clinical studies on stereotactic body radiotherapy (SRT) using the 3 D-CRT technique for solitary lung tumors have been reported.

View Article and Find Full Text PDF

Purpose: Positional reproducibility in patients with prostate cancer fixed in the prone position with a set of immobilization devices for external-beam intensity-modulated radiation therapy (IMRT) was evaluated. In addition, the adequacy of our positional error reduction strategy and current planning target volume (PTV) margins was also evaluated.

Results: Systematic error was corrected by the positional correction that we executed at the first stage of irradiation.

View Article and Find Full Text PDF