Publications by authors named "Shinji Ninomiya"

Aim: This study aimed to elucidate the risk of electric shock when the general public, not wearing Personal Protective Equipment (PPE), is in contact with a patient, and a defibrillation shock is inadvertently delivered.

Methods: A simulation study was conducted simulating the following scenarios. 1) Both the rescuer and the patient were isolated from the ground, with the rescuer making single-point contact with the patient.

View Article and Find Full Text PDF

Cardiopulmonary bypass (CPB) is an indispensable technique in cardiac surgery, providing the ability to temporarily replace cardiopulmonary function and create a bloodless surgical field. Traditionally, the operation of CPB systems has depended on the expertise and experience of skilled perfusionists. In particular, simultaneously controlling the arterial and venous occluders is difficult because the blood flow rate and reservoir level both change, and failure may put the patient's life at risk.

View Article and Find Full Text PDF

Tracheal suctioning is an important procedure to maintain airway patency by removing secretions. Today, suctioning operators include not only medical staff, but also family caregivers. The use of a simulation system has been noted to be the most effective way to learn the tracheal suctioning technique for operators.

View Article and Find Full Text PDF

Background: To provide safe tracheal suctioning, the American Association of Respiratory Care guideline discusses the length of suctioning catheter, but the most effective tracheal suctioning catheter technique is still unknown.

Objective: The aim of this study is to compare the amount of simulated secretion produced by five different handlings of a catheter at two different viscosities and in two different models to discover the most effective suctioning maneuver in the various mucus conditions.

Design: In vitro experimental design.

View Article and Find Full Text PDF

Degradation of dialysis efficiency during hemodialysis, caused by incompatible indwelling needle size or increase in hematocrit, is a serious problem that can threaten a patient's life. This study aims to derive a quantitative index for determining the indwelling needle diameter that can maintain an appropriate blood flow rate, and presents an effective method to prevent a decrease in the actual blood flow rate. The relationships between the set flow rate and various parameters such as indwelling needle diameter, blood viscosity, and arterial line pressure are analyzed.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to find the best biomechanical technique for suctioning phlegm using a new simulator and motion capture system.
  • They compared the performance of 12 experienced nurses and 12 nursing students to measure how much phlegm was suctioned and analyze the hand movements involved.
  • Results showed experienced nurses suctioned more phlegm per second, suggesting that better wrist motion and thumb rotation enhance suctioning efficiency, potentially making deep suctioning unnecessary and safer.
View Article and Find Full Text PDF

A physically active lifestyle is associated with better health in body and mind, and it is urgent that supporting agents for such lifestyles be developed. In rodents, voluntary locomotor activity as an active physical behavior may be mediated by dopaminergic neurons (DNs). Thiamine phosphate esters can stimulate DNs, and we thus hypothesized that thiamine tetrahydrofurfuryl disulfide (TTFD), a thiamine derivative, promotes locomotor activity via DNs in rats.

View Article and Find Full Text PDF

Purpose: Thiamine is an essential component of glucose metabolism and energy production. The disulfide derivative, thiamine tetrahydrofurfuryl disulfide (TTFD), is better absorbed than readily-available water-soluble thiamine salts because it does not require the rate-limiting transport system required for thiamine absorption. However, the detailed pharmacokinetics of thiamine and TTFD under normal and pathological conditions have not yet been clarified.

View Article and Find Full Text PDF

To enable in vivo analysis of the kinetics of vitamin B1 (thiamine) and its derivatives by positron emission tomography (PET), (11)C-labeled thiamine ([(11)C]-1) has been synthesized. This was carried out via a rapid, multistep synthesis consisting of Pd(0)-mediated C-[(11)C]methylation of a thiazole ring for 3 min and benzylation with 5-(bromomethyl)pyrimidine for 7 min. The [(11)C]-1 was also converted to (11)C-labeled fursultiamine ([(11)C]-2), a prodrug of vitamin B1, by disulfide formation with S-tetrahydrofurfurylthiosulfuric acid sodium salt.

View Article and Find Full Text PDF

The operation of cardiopulmonary bypass procedure requires an advanced skill in both physiological and mechanical knowledge. We developed a virtual patient simulator system using a numerical cardiovascular regulation model to manage perfusion crisis. This article evaluates the ability of the new simulator to prevent perfusion crisis.

View Article and Find Full Text PDF

Although serious accidents during extracorporeal circulation are infrequent, potential adverse events with both equipment and operation do still occur and require immediate and well-coordinated responses. Hence, perfusionists need to be well trained in both standard and emergency procedures, and this would be aided by the establishment of an official education and training curriculum. In particular, the establishment of a simulator-based educational program and corresponding evaluation methods will spur development of increasingly medical simulators.

View Article and Find Full Text PDF

Perfusionists require a detailed understanding of a patient's physiological status while comprehending the mechanics and engineering of the cardiopulmonary bypass system, so it is beneficial for them to obtain relevant practical skills using extracorporeal circulation technology and educational physiological simulators. We designed a perfusion simulator system (ECCSIM: Extracorporeal Circulation SIMulator system) based on a hybrid of a simple hydraulic mock circulation loop linked to a computer simulation model. Patient physiological conditions (height, weight, and cardiac indices) were determined by a parameter estimation procedure and used to accurately reproduce hemodynamic conditions.

View Article and Find Full Text PDF

In order to develop a diaphragm-type ventricular assist device (VAD), we studied the flow field change following structural modifications. We devised a center flow-type pump by putting a small projection on the center of the housing and/or diaphragm to provide a center in the flow field, and examined the following four types of VADs: N type without a projection, D type with a projection on the diaphragm, H type with a projection on the housing, and DH type with projections on both the diaphragm and housing. Computational fluid dynamics (CFD) was used for flow simulation.

View Article and Find Full Text PDF

The heart-lung machines for open-heart surgery have improved over the past 50 years; they rarely break down and are almost always equipped with backup batteries. The hand-cranking procedure only becomes necessary when a pump breaks down during perfusion or after the batteries have run out. In this study, the performance of hand cranking a roller pump was quantitatively assessed by an objective method using the ECCSIM-Lite educational simulator system.

View Article and Find Full Text PDF

A training system with quantitative evaluation of performance for training perfusionists is valuable for preparation for rare but critical situations. A simulator system, ECCSIM-Lite, for extracorporeal circulation (ECC) training of perfusionists was developed. This system consists of a computer system containing a simulation program of the hemodynamic conditions and the training scenario with instructions, a flow sensor unit, a reservoir with a built-in water level sensor, and an ECC circuit with a soft bag representing the human body.

View Article and Find Full Text PDF

We developed a small, lightweight, low-cost implantable ventricular assist device (VAD) for use in smaller Japanese subjects. The major advantage of this pump is the simplicity of its fabrication. Most parts of the pump were shaped from a transparent acrylic block by a turning process, and the diaphragm was made from a silicon sheet.

View Article and Find Full Text PDF

The effect of simultaneous administration of vitamin C (ascorbic acid), L-cystein (Cys) and vitamin E (tocopherol) on the melanogenesis in vivo and in vitro was studied. Forty-eight brownish guinea pigs were divided into 4 groups as follows: VC group, VC+Cys group, VC+Cys+VE group and control group. They were given these vitamins by oral administration every day.

View Article and Find Full Text PDF