In high-intensity focused ultrasound (HIFU) treatment, a method that monitors tissue changes while irradiating therapeutic ultrasound is needed to detect changes in the order of milliseconds due to thermal coagulation and the presence of cavitation bubbles. The new filtering method in which only the HIFU noise was reduced while the tissue signals remained intact was proposed in the conventional HIFU exposure in our preliminary study. However, HIFU was irradiated perpendicular to the direction of the imaging ultrasound in the preliminary experiment, which was believed to be impractical.
View Article and Find Full Text PDFBackground/aim: Sonodynamic cancer therapy is based on the preferential uptake and/or retention of a sonosensitizing drug (sonosensitizer) in tumor tissues and the subsequent activation of the drug by ultrasound irradiation. In the present study, we investigated the sonodynamically-induced antitumoral effect with functionalized carbon nanotubes, such as poly-ethylene glycol-modified carbon nanotubes (PEG-modified CNTs).
Materials And Methods: Antitumor effects were evaluated using histological observation and assessing tumor growth following sonodynamic exposure to PEG-modified CNTs.
Sonodynamic therapy (SDT) is a minimally invasive anticancer therapy involving a chemical sonosensitizer and high-intensity focused ultrasound (HIFU). SDT enables the reduction of drug dose and HIFU irradiation power compared to those of conventional monotherapies. In our previous study, mouse models of colon and pancreatic cancer were used to confirm the effectiveness of SDT vs.
View Article and Find Full Text PDFSonodynamic therapy (SDT) consists of the synergetic interaction between ultrasound and a chemical agent. In SDT, the cytotoxicity is triggered by ultrasonic stimuli, notably through cavitation. The unique features of SDT are relevant in the clinical context more than ever: the need for efficacy, accuracy, and safety while being noninvasive and preserving the patient's quality of life.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
April 2018
Cavitation is a critical parameter in various therapeutic applications involving ultrasound (US) such as histotrispy, lithothripsy, drug delivery, and cavitation-enhanced hyperthermia. A cavitation exposure outside the region of interest may lead to suboptimal treatment efficacy or in a worse case, to safety issues. Current methods of localizing cavitation are based on imaging approaches, such as beamforming the cavitation signals received passively by a US imager.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
July 2018
Nanobubbles (NBs) are of high interest for ultrasound (US) imaging as contrast agents and therapy as cavitation nuclei. Because of their instability (Laplace pressure bubble catastrophe) and low sensitivity to US, reducing the size of commonly used microbubbles to submicron-size is not trivial. We introduce stabilized NBs in the 100-250-nm size range, manufactured by agitating human serum albumin and perfluoro-propane.
View Article and Find Full Text PDFMetastasis frequently occurs even in the early stage of breast cancer. This research studied the feasibility of using photoacoustic (PA) imaging for identifying metastasis in the lymph vessels of mice. The photoacoustic efficiency of various contrast agents was investigated, and the influence of scattered light was evaluated by using a lymph vessel phantom.
View Article and Find Full Text PDFSonodynamic therapy (SDT) is currently considered as one of the promising minimally invasive treatment options for solid cancers. SDT is based on the combined use of a sonosensitizer drug and high-intensity focused ultrasound (HIFU) to produce cytotoxic reactive oxygen species (ROS) in and around neoplastic cells. Anthracycline drugs, including epirubicin (EPI), have been well known as effective sonosensitizers after interaction with focused ultrasound.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
August 2017
Photoacoustic (PA) imaging is a promising imaging modality to visualize specific living tissues based on the light absorption coefficients without dyeing. In this paper, a real-time PA imaging system with a tunable laser was newly developed with an originally designed spherically curved array transducer. Five different series of experiments were conducted to validate the PA measurement system.
View Article and Find Full Text PDFPurpose: The objective of the present study was to develop a high-intensity focused ultrasound (HIFU) transducer more suitable for clinical use in fetal therapy for twin reversed arterial perfusion (TRAP) sequence.
Materials And Methods: We created a cooling and degassed water-circulating-type HIFU treatment device. HIFU was applied to renal branch vessels in three rabbits.
Ultrasound has been widely utilized for medical diagnosis and therapy due to its ability to penetrate deep-seated tissue with less attenuation of energy and minimal undesirable side-effects. Functionalized fullerenes, such as polyhydroxy fullerene (PHF), have attracted particular attention due to their water solubility and potential application in tumor imaging and therapy as carbon nanomaterials. The present study investigated sonodynamically-induced apoptosis using PHF.
View Article and Find Full Text PDFBackground: A noninvasive technique to monitor thermal lesion formation is necessary to ensure the accuracy and safety of high-intensity focused ultrasound (HIFU) treatment. The purpose of this study is to ultrasonically detect the tissue change due to thermal coagulation in the HIFU treatment enhanced by cavitation microbubbles.
Methods: An ultrasound imaging probe transmitted plane waves at a center frequency of 4.
Annu Int Conf IEEE Eng Med Biol Soc
August 2016
We propose a new estimation method of tissues stiffness from deformation induced by arterial pulsation. The new method was named Intrinsic Elastography (IE). Under two assumptions that the deformation induced by pulsation propagates throughout the body, and the propagation velocity (PV) is closely related to the mechanical properties of tissues, the IE can evaluate the tissue stiffness based on the PV.
View Article and Find Full Text PDFObjective: To examine how connective tissue diseases affect finger-vein pattern authentication.
Methods: The finger-vein patterns of 68 patients with connective tissue diseases and 24 healthy volunteers were acquired. Captured as CCD (charge-coupled device) images by transmitting near-infrared light through fingers, they were followed up in once in each season for one year.
Air-backed transducers have been employed for thermal ultrasonic treatment including both ablation and hyperthermia because the power efficiency rather than the bandwidth is a main concern, unlike a typical imaging transducer working in a pulse mode. The characteristic of an air-backed piezoelectric transducer with a matching layer is analysed, and the role and choice of the matching layer is discussed. An element size of a focused array transducer, appropriate for such thermal treatment, is then estimated, and the characteristic of a piezoceramic transducer element of such a size was numerically analysed using a finite element code.
View Article and Find Full Text PDFBackground/aim: Sonodynamic cancer therapy is based on the preferential uptake and/or retention of a sonosensitizing drug (sonosensitizer) in tumor tissues and subsequent activation of the drug by ultrasound irradiation. In the present study, we investigated the participation of lipid peroxidation in the mechanism of the sonodynamically-induced antitumor effect with functionalized fullerenes, such as polyhydroxy fullerene (PHF.
Materials And Methods: Ultrasonically-induced cell damage and lipid peroxidation with PHF were compared in the same in vitro insonation setup.
Pulse-wave velocity (PWV) is an important index for diagnosing cardiovascular diseases. The pulse wave is volumetric change induced by heartbeat or inflowing blood, and significantly depends on the propagating path and stiffness of the artery. In this study, PWV of the propagating wave was visualized using spatial compound imaging with high temporal resolution.
View Article and Find Full Text PDFUltrasonic imaging has advantages in its self-consistency in guiding and monitoring ultrasonic treatment such as high-intensity focused ultrasound (HIFU) treatment. Changes in ultrasonic backscatter of tissues due to HIFU treatment have been observed, but their mechanism is still under discussion. In this paper, ultrasonic backscatter of excised and degassed porcine liver tissue was observed before and after HIFU exposure using a diagnostic scanner, and its acoustic impedance was mapped using an ultrasonic microscope.
View Article and Find Full Text PDFCavitation bubbles are known to accelerate therapeutic effects of ultrasound. Although negative acoustic pressure is the principle factor of cavitation, positive acoustic pressure has a role for bubble cloud formation at a high intensity of focused ultrasound when cavitation bubbles provide pressure release surfaces converting the pressure from highly positive to negative. In this study, the second-harmonic was superimposed onto the fundamental acoustic pressure to emphasize either peak positive or negative pressure.
View Article and Find Full Text PDFBackground: Functionalized fullerenes, such as polyhydroxy fullerenes (PHF), have attracted particular attention due to their water solubility and their potential application in tumor imaging and therapy as carbon nanomaterials. In this study, the sonodynamically-induced antitumor effect of PHF was investigated.
Materials And Methods: Sonodynamically-induced antitumor effects of PHF in combination with ultrasound were investigated using isolated sarcoma 180 cells and solid tumor from colon 26 carcinoma cells.
In this study, we investigated the induction of apoptosis by ultrasound in the presence of the novel porphyrin derivative DCPH-P-Na(I). HL-60 cells were exposed to ultrasound for up to 3 min in the presence and absence of DCPH-P-Na(I), and the induction of apoptosis was examined by analyzing cell morphology, DNA fragmentation, and caspase-3 activity. Reactive oxygen species were measured by means of ESR and spin trapping technique.
View Article and Find Full Text PDFWe investigated the safety of transcranial-targeting midfrequency (0.1 to 1 MHz) ultrasonic thrombolysis for acute ischemic stroke. We applied a new therapeutic and imaging transducer to healthy Macaca monkey brains via sonication of the ipsilateral middle cerebral artery through an acoustic temporal window.
View Article and Find Full Text PDF