Cardiovasc Interv Ther
October 2024
Heart failure with reduced ejection fraction (HFrEF) has a high mortality rate, and cardiac rehabilitation programs (CRP) reduce HFrEF rehospitalization and mortality rates. Some countries attempt 3 weeks of inpatient CRP (3w In-CRP) for cardiac diseases. However, whether 3w In-CRP reduces the prognostic parameter of the Metabolic Exercise data combined with Cardiac and Kidney Indexes (MECKI) score is unknown.
View Article and Find Full Text PDFPhysiological assessments using fractional flow reserve (FFR) and resting full-cycle ratio (RFR) have been recommended for revascularization decision making. Previous studies have shown a 20% rate of discordance between FFR and RFR. In this context, the correlation between RFR and FFR in patients with renal dysfunction remains unclear.
View Article and Find Full Text PDFBackground: High-resolution intravascular ultrasound (HR-IVUS) is the most recently developed IVUS technology, which allows the detailed assessment of intravascular structures. The aim of this study was to evaluate the diagnostic performance of HR-IVUS in the detection of abnormal post-stent findings.
Methods and results: Patients with acute coronary syndrome underwent both HR-IVUS and optical coherence tomography (OCT) for post-stent evaluations.
The resting full-cycle ratio (RFR), a novel resting index, is well correlated with and shows good diagnostic accuracy to the fractional flow reserve (FFR). However, discordance results between the RFR and FFR have been observed to occur in about 20% of cases. This study aimed to clarify the prevalence and factors of discordant results between the RFR and FFR through a direct comparison of these values in daily clinical practice.
View Article and Find Full Text PDFObjective: To evaluate the effect of triglyceride deposit cardiomyovasculopathy (TGCV) on the cardiovascular outcomes in haemodialysis (HD) patients with suspected coronary artery disease (CAD).
Methods: This retrospective single-centre observational study included data from the cardiac catheter database of Narita Memorial Hospital between April 2011 and March 2017. Among 654 consecutive patients on HD, the data for 83 patients with suspected CAD who underwent both [I]-β-methyl-iodophenyl-pentadecanoic acid scintigraphy and coronary angiography were analysed.
Int J Cardiovasc Imaging
February 2021
The healing process of acute incomplete stent apposition (ISA) in the early phase after stent implantation has not been well understood. We evaluated the temporal changes of ISA during the early phase after everolimus-eluting stent (EES) implantation using serial optical coherence tomography (OCT) analyses. Serial OCT examinations were performed immediately post-stenting and 2-week and 4-month after EES implantation for patients with ST-segment elevation myocardial infarction.
View Article and Find Full Text PDFAlthough drug-eluting stents have improved clinical outcomes, percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) remains a challenging procedure in terms of thrombus management. A new-generation P2Y12 receptor inhibitor, prasugrel, provides more rapid and potent antiplatelet action compared with clopidogrel. Prasugrel achieved significant reduction of ischemic events compared with clopidogrel in ACS.
View Article and Find Full Text PDFThe resting full-cycle ratio (RFR) is a new physiologic index to assess myocardial ischemia. RFR and fractional flow reserve (FFR), the conventionally used index, have not been directly compared in evaluating the entire cardiac cycle. Accordingly, we aimed to compare the diagnostic performance of RFR directly with FFR and clarify the clinical feasibility of RFR as a unique non-hyperemic index in evaluating the cardiac cycle.
View Article and Find Full Text PDFObjective Although acute coronary syndrome (ACS) is an uncommon entity in young patients, it constitutes an important problem due to the devastating effects of the disease on the more active lifestyle of young patients. At present, there are no guidelines regarding the prevention of ACS in young patients. Methods We performed a retrospective study of ACS patients between 2014 and 2017.
View Article and Find Full Text PDFBackground: Fractional flow reserve (FFR) measurement is the gold standard for identifying the functional severity of coronary artery disease. Although we can use newly developed pressure wires with optical fibers are now available, their safety and accuracy for FFR measurement are not clear. Therefore, we planned a clinical comparison study between pressure wires with optical fibers and the conventional FFR device.
View Article and Find Full Text PDFBackground: The new 60-MHz high-resolution intravascular ultrasound (HR-IVUS) is the next-generation IVUS technology, providing higher image resolution than conventional IVUS. It gives clear images of plaque morphology and can discriminate the underlying mechanism of acute coronary syndrome (ACS). Our study aimed to evaluate the diagnostic performance of 60-MHz HR-IVUS in the detection of plaque rupture in patients with ACS.
View Article and Find Full Text PDFBackground: Despite the revolution of coronary stents, there remain concerns about the risk of stent thrombosis, especially in patients with ST-elevation myocardial infarction (STEMI). The present study compared early vascular healing as a contributing factor to reducing stent thrombosis between Xience everolimus-eluting stents (X-EES) and Synergy everolimus-eluting stents (S-EES) in patients with STEMI.
Methods and results: The present study included 47 patients with STEMI requiring primary percutaneous coronary intervention with X-EES (n=25) or S-EES (n=22).
Background: Poststent fractional flow reserve (FFR) is a useful indicator of optimal percutaneous coronary intervention, and higher poststent FFR is associated with favorable long-term clinical outcome. However, little is known about the factors influencing poststent FFR. The purpose of this study was to determine the impact of lesion characteristics on poststent FFR.
View Article and Find Full Text PDFAlthough late restenosis is one of the long-term complications of stent implantation, its pathogenesis has not been fully elucidated. For consecutive patients who developed in-stent restenosis (ISR) after stent implantation, integrated backscatter (IB) intravascular ultrasound was performed for ISR lesions. The tissue characteristics of neointima within the stented segment were compared between lesions with early restenosis and those with late restenosis.
View Article and Find Full Text PDFThe aim of this study was to determine the correlation between the fractional flow reserve (FFR) values and volumetric intravascular ultrasound (IVUS) parameters derived from classic gray-scale IVUS and integrated backscatter (IB)-IVUS, taking into account known confounding factors. Patients with unstable angina pectoris with the frequent development of vulnerable plaques often showed the discrepancy between the FFR value and the quantitative coronary angiography findings. Our target population was 107 consecutive subjects with 114 isolated lesions who were scheduled for elective coronary angiography.
View Article and Find Full Text PDFBackground: Although functional ischemia identification is important when determining revascularization, angiographic assessment alone is challenging in intermediate coronary stenosis. Previous studies have reported that lesion-specific characteristics affected the fractional flow reserve (FFR). However, the relationship between morphological lesion complexity and FFR has not yet been fully evaluated.
View Article and Find Full Text PDFPhospholipase D (PLD) catalyzes transphosphatidylation, causing inter-conversion of the polar head group of phospholipids and phospholipid hydrolysis. Previously, we cloned PLD103, a PLD with high transphosphatidylation activity, from Streptomyces racemochromogenes strain 10-3. Here, we report the construction of an expression system for the PLD103 gene using Streptomyces lividans as the host bacterium to achieve large-scale production.
View Article and Find Full Text PDFFacile access to complex systems is crucial to generate the functional materials of the future. Herein, we report self-organizing surface-initiated polymerization (SOSIP) as a user-friendly method to create ordered as well as oriented functional systems on transparent oxide surfaces. In SOSIP, self-organization of monomers and ring-opening disulfide exchange polymerization are combined to ensure the controlled growth of the polymer from the surface.
View Article and Find Full Text PDFWe report a unique macromolecule consisting of a rodlike helical polyisocyanide backbone with a narrow molecular weight distribution and rigid mesogenic chiral pendants linked via a flexible spacer that exhibits lyotropic nematic and latticelike new smectic (lat-Sm) liquid crystal phases at different concentrations. The unprecedented lat-Sm phase is associated with the smectic ordering of both the stiff polymer backbone and the rigid-rod side groups. A detailed investigation of the films using X-ray scattering and atomic force microscopy revealed a novel tilted smectic layer structure of the polymer backbone aligned perpendicular to the smectic layer of the mesogenic pendants, which arrange in an antiparallel overlapping interdigitated manner.
View Article and Find Full Text PDFOptically active poly(phenylacetylene) copolymers consisting of optically active and achiral phenylacetylenes bearing L-alanine decyl esters (1L) and 2-aminoisobutylic acid decyl esters (Aib) as the pendant groups (poly(1L(m)-co-Aib(n))) with various compositions were synthesized by the copolymerization of the optically active 1L with achiral Aib using a rhodium catalyst, and their chiral amplification of the macromolecular helicity in a dilute solution, a lyotropic liquid crystalline (LC) state, and a two-dimensional (2D) crystal on the substrate was investigated by measuring the circular dichroism of the copolymers, mesoscopic cholesteric twist in the LC state (cholesteric helical pitch), and high-resolution atomic force microscopy (AFM) images of the self-assembled 2D helix-bundles of the copolymer chains. We found that the macromolecular helicity of poly(1L(m)-co-Aib(n))s could be hierarchically amplified in the order of the dilute solution, LC state, and 2D crystal. In sharp contrast, almost no chiral amplification of the macromolecular helicity was observed for the homopolymer mixtures of 1L and Aib in the LC state and 2D crystal on graphite.
View Article and Find Full Text PDF