Publications by authors named "Shin Wook Kim"

The nondestructive dosimetry achieved with electron paramagnetic resonance (EPR) dosimetry facilitates repetitive recording by the same dosimeter to increase the reliability of data. In precedent studies, solid paraffin was needed as a binder material to make the lithium formate monohydrate (LFM) EPR dosimeter stable and nonfragile; however, its use complicates dosimetry. This study proposes a newly designed pure LFM EPR dosimeter created by inserting LFM into a 3D-printed container.

View Article and Find Full Text PDF

Objective: Various methods for radiation-dose calculation have been investigated over previous decades, focusing on the use of magnetic resonance imaging (MRI) only. The bulk-density-assignment method based on manual segmentation has exhibited promising results compared to dose-calculation with computed tomography (CT). However, this method cannot be easily implemented in clinical practice due to its time-consuming nature.

View Article and Find Full Text PDF

Purpose: We aimed to evaluate the feasibility of the heart block with electron compensation (HBE) technique, based on three-dimensional conformal radiotherapy (3D-CRT) in left-sided breast cancer patients with underlying cardiac or pulmonary disease.

Methods: Twenty patients with left-sided breast cancer who were treated with whole breast radiotherapy (WBRT) were included in this study. Intensity-modulated radiotherapy (IMRT), 3D-CRT, and HBE treatment plans were generated for each patient.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to identify a more suitable boost plan for simultaneously integrated boost scheme in patients with breast cancer by comparing among 3 types of whole-breast irradiation plus tumor bed boost plans.

Methods: Twenty patients who received radiotherapy following breast-conserving surgery for early breast cancer were enrolled in this study. We performed 1 type of electron plan (E1P plan) and 2 types of 3-dimensional conformal plans using a photon (P3P and P5P plans).

View Article and Find Full Text PDF

The purpose of this study was to evaluate the skin-sparing effects of 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) in patients with early left-sided breast cancer. Twenty left breast cancer patients treated with whole breast radiotherapy following breast-conserving surgery were enrolled in this study, and the 3D-CRT and IMRT plans were generated for each patient. To evaluate the dose delivered to the skin, 2 mm thickness skin (2-mm skin) and 3 mm thickness skin (3-mm skin) were contoured and a dosimetric comparison between the 2 plans was performed.

View Article and Find Full Text PDF

The purpose of this study was to compare the dosimetric parameters for incidental irradiation to the axilla during whole breast radiotherapy (WBRT) with 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). Twenty left breast cancer patients treated with WBRT after breast-conserving surgery (BCS) were enrolled in this study. Remnant breast tissue, 3 levels of the axilla, heart, and lung were delineated.

View Article and Find Full Text PDF

Objective: Boluses are used in high-energy radiotherapy in order to overcome the skin sparing effect. In practice though, commonly used flat boluses fail to make a perfect contact with the irregular surface of the patient's skin, resulting in air gaps. Hence, we fabricated a customized bolus using a 3-dimensional (3D) printer and evaluated its feasibility for radiotherapy.

View Article and Find Full Text PDF