A system to perform post-column derivatization capillary electrochromatography (CEC) was developed for the first time. The system mainly included a 4-microm (O.D.
View Article and Find Full Text PDFThis paper presents a new method for making frit using soft-ferrite-based micro-magnetic particles (MMPs) in a micro-space, such as in a capillary tube. The MMPs-frit was made by injecting an aliquot of 10 microm (outer diameter; o.d.
View Article and Find Full Text PDFA simple, practical technique is presented for the selective determination and measurement of histamine (HA) levels in fermented food. The method involved a solid-phase extraction cleanup using a Sep-Pak Plus C-18 cartridge and ion-paired reversed-phase high-performance liquid chromatographic (IP-RP-HPLC) separation, followed by detection of HA at its UV absorbance wavelength of 220nm. After evaporating a methanolic extract from the food sample, the resulting residue was reconstituted with 0.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
November 2006
A method of pinpoint-sampling followed by on-line pre-concentration of the sample, throughout in-capillary derivatization and capillary electrophoretic separation was evaluated by demonstrating the detection of taurine, 2-aminoethanesulfonic acid at a specific location of a rat brain. The direct sampling of taurine from the rat brain was accomplished by using voltage injection associated with two kinds of driving forces, electrophoretic flow and electroosmotic flow (EOF). The capillary tube (75 microm of inner diameter x 375 microm of outer diameter) of the capillary electrophoresis (CE) apparatus was already filled with a CE run buffer, viz.
View Article and Find Full Text PDFA new strategy for the selective determination of D-amino acids (DAAs) employing a pre-column derivatization was designed with concepts based on both enzymatic and chemical modifications. Selective determination of DAAs was accomplished by following: DAA was enzymatically modified with D-amino acid oxidase (DAAO: EC 1.4.
View Article and Find Full Text PDFThe elution behaviors of the biogenic amines, histamine (HA) and its metabolite methyl histamine (MHA), were evaluated by means of on-column derivatization (OCD)-capillary electrochromatography (CEC) which employed a monolithic octadecylsilica (ODS) capillary column (20 cm of effective length x 50 microm of inner diameter). Five kinds of alkylthiols, e.g.
View Article and Find Full Text PDFWe report on the effect on performance of varying the length of the capillary during throughout in-capillary derivatization (TICD) capillary electrophoresis (CE). Performance was evaluated by on-line coupling with a sample and CE runbuffer loading device that was newly introduced for this study. The device was assembled with a low cost using two 5 mm inner diameter (ID) disposable polyethylene syringes.
View Article and Find Full Text PDFTo expand the applications of the on-line preconcentration technique with capillary electrochromatography (CEC) to biogenic amines that have no specific chromophore or fluorophore in their molecules, a method of on-line preconcentration prior to on-column derivatization CEC is presented. A monolithic ODS capillary column (20 cm effective length x 75 microm i.d.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
December 2002
This review provides an overview of the assay methods used to determine the presence of endogenous histamine (HA) including its metabolites, and also discusses their biological significance. Firstly, this review briefly summarizes the biological significance of HA and its biological pathways. Next, the assay methods with microseparation techniques, such as gas-chromatography (GC), liquid-chromatography (LC), capillary electrophoresis (CE) and capillary electrochromatography (CEC) are looked at from a developmental viewpoint.
View Article and Find Full Text PDFA selective detection method for biogenic amines present in highly complex matrixes was devised by employing both electrokinetic injection and on-column-derivatization capillary electrochromatographic methods. The on-column derivatization capillary electrochromatography system was evaluated by use of a capillary column (total length of 45 cm, effective length of 25 cm) fabricated using a 100-mcirom (i.d.
View Article and Find Full Text PDF