Introduction: Atrial pacing maps are often used as substitutes for sinus rhythm (SR) maps to expedite mapping procedures. However, the impact of this method on electrophysiological parameters has not been systematically examined. This study aimed to elucidate the advantages and limitations of atrial pacing maps.
View Article and Find Full Text PDFIntroduction: The suitability of high-power short-duration (HPSD) cavo-tricuspid isthmus ablation (CTI-Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI-Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate-power long duration (MPLD) ablations.
Methods: Study 1: CTI-Abl was performed by first- to fourth-year EP trainees in consecutive 113 patients (67 ± 11 years, 27.
Purpose: Very high-power short-duration (vHPSD) ablation creates shallower lesions, potentially reducing efficacy. This study aims to identify factors leading to insufficient lesions during pulmonary vein antral isolation (PVAI) with vHPSD-ablation and to develop an optimized PVAI strategy using this technology.
Methods: PVAI was performed on 41 atrial fibrillation patients using vHPSD-ablation (90 W/4 s).
Background: Very high power and short duration (vHPSD) ablation is recently used for pulmonary vein isolation. However, low first-pass isolation rates have been reported, possibly because of shallow lesion formation, necessitating deeper lesions to improve treatment outcomes.
Objective: This study aimed to confirm the safety and efficacy of double radiofrequency applications of vHPSD ablation in an in vivo beating swine heart model.
Background: Ethanol infusion into the vein of Marshall (EIVOM) has been performed as an adjunctive atrial fibrillation therapy. However, the time course change, quantitative lesion investigation, and effects on epicardial fat pads and fractionated atrial electrograms created by EIVOM have never been investigated.
Objective: This study aimed to perform a quantitative analysis of lesions created by EIVOM.
Background: We explore an optimized approach for increasing lesion size using a novel ablation catheter with a surface thermocouple and efficient irrigation in a temperature-control setting.
Methods: We conducted radiofrequency applications at various power levels (35 W, 40 W, and 45 W), contact forces (CFs, 10 g/20 g), and durations (60 s/120 s/180 s) in perpendicular/parallel catheter orientations, with normal saline irrigation (NS-irrigation) and Half NS-irrigation (HNS-irrigation) in an ex-vivo model (Step 1). In addition, we performed applications (35 W/40 W/45 W for 60 s/120 s/180 s in NS-irrigation and 35 W/40 W for 60 s/120 s/180 s in HNS-irrigation) in four swine (Step 2), evaluating lesion characteristics and the occurrence of steam pops.
Strigolactones (SLs) are plant apocarotenoids with diverse roles and structures. Canonical SLs, widespread and characterized by structural variations in their tricyclic lactone (ABC-ring), are classified into two types based on C-ring configurations. The steric C-ring configuration emerges during the BC-ring closure, downstream of the biosynthetic intermediate, carlactonoic acid (CLA).
View Article and Find Full Text PDFBackground: The innovative peak frequency mapping facilitates the quantification of electrogram sharpness. However, reference values for normal atrial tissue are currently undefined. In this study, we explored the distribution of peak frequency and omnipolar peak-to-peak voltage (V-max) in a normal heart.
View Article and Find Full Text PDFBackground: The anatomical approach for the management of para-Hisian ventricular arrhythmias (VAs) with QRS morphological changes after catheter ablation (CA) has not been well investigated.
Objective: We aimed to evaluate the electrocardiographic and electrophysiological findings and ablation outcomes of para-Hisian VAs with QRS morphological changes after CA.
Methods: Of the 30 patients who underwent CA for para-Hisian VAs at 4 institutions, 10 (33%) had QRS morphological changes after ablation.
Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study.
Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter.
The C3 carbon of glucose molecules becomes the C1 carbon of pyruvate molecules during glycolysis, and the C1 and C2 carbons of glucose molecules are metabolized in the tricarboxylic acid (TCA) cycle. Utilizing this position-dependent metabolism of C atoms in glucose molecules, [1-C], [2-C], and [3-C]glucose breath tests are used to evaluate glucose metabolism. However, the effects of chronic ethanol consumption remain incompletely understood.
View Article and Find Full Text PDFBackground: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging.
Objective: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms.
Background: Phrenic nerve injury (PNI) is one of the common complications in atrial fibrillation (AF) ablation, which often recovers spontaneously. However, the course of its recovery has not been examined fully, especially in regard to the different ablation methods. We sought to compare the recovery course of PNI in cryoballoon, laser balloon, and radiofrequency ablation.
View Article and Find Full Text PDFAims: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients.
View Article and Find Full Text PDFBackground And Aims: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter.
Methods: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.
J Interv Card Electrophysiol
September 2024
Background: A left atrial posterior wall isolation (LAPWI) is one of the atrial fibrillation (AF) ablation strategies.
Hypothesis: We hypothesized that an additional empirical LAPWI would increase the freedom from recurrent atrial arrhythmias as compared to standard AF ablation in persistent AF patients.
Methods: The CORNERSTONE AF study is a prospective, randomized, multicenter study investigating patients with AF persisting for >7 days and <3 years undergoing first-time AF ablation.
Introduction: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures.
Methods: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed.
Background: Slow pathway elimination of the atrioventricular node (AVN) is essential to treat AVN reentrant tachycardia (AVNRT). However, injury to the AVN conduction (IAVN) is one of the serious complications. Cryofreezing energy is expected to reduce the incidence of IAVN.
View Article and Find Full Text PDFBackground: Several studies have reported a relationship between elevated serum adiponectin levels and poor outcomes in patients with heart failure (HF). However, data on the activities of daily living (ADL) in elderly patients with HF are limited.
Methods: We evaluated 218 hospitalized elderly (≥65 years) patients with HF who underwent a comprehensive cardiac rehabilitation (CR) program during hospitalization.
Aims: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping.
Objective: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization.
Methods: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed.
Background/purpose: The incidence of medication-related osteonecrosis of the jaw is increasing worldwide, mostly due to the use of antiresorptive agents (ARAs) such as bisphosphonate (BP) and denosumab (Dmab). However, the proportion of BP-related osteonecrosis of the jaw (BRONJ) and Dmab-related osteonecrosis of the jaw (DRONJ) among all ARA-related osteonecrosis of the jaw (ARONJ) cases is not clear; this hinders appropriate treatment, recurrence-prevention planning, and avoidance of unnecessary Dmab withdrawal. Moreover, the causative drug administered at each disease stage remains unknown.
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
August 2023
Introduction: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops.
Methods: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations.