Mixed reality (MR) technologies have a high potential to enhance obstacle negotiation training beyond the capabilities of existing physical systems. Despite such potential, the feasibility of using MR for obstacle negotiation on typical training treadmill systems and its effects on obstacle negotiation performance remains largely unknown. This research bridges this gap by developing an MR obstacle negotiation training system deployed on a treadmill, and implementing two MR systems with a video see-through (VST) and an optical see-through (OST) Head Mounted Displays (HMDs).
View Article and Find Full Text PDFA fall on stairs can be a dangerous accident. An important indicator of falling risk is the foot clearance, which is the height of the foot when ascending stairs or the distance of the foot from the step when descending. We developed an augmented reality system with a holographic lens using a visual illusion to improve the foot clearance on stairs.
View Article and Find Full Text PDFMultifingered robot hands can be extremely effective in physically exploring and recognizing objects, especially if they are extensively covered with distributed tactile sensors. Convolutional neural networks (CNNs) have been proven successful in processing high dimensional data, such as camera images, and are, therefore, very well suited to analyze distributed tactile information as well. However, a major challenge is to organize tactile inputs coming from different locations on the hand in a coherent structure that could leverage the computational properties of the CNN.
View Article and Find Full Text PDFEstimating the driver's gaze in a natural real-world setting can be problematic for different challenging scenario conditions. For example, faces will undergo facial occlusions, illumination, or various face positions while driving. In this effort, we aim to reduce misclassifications in driving situations when the driver has different face distances regarding the camera.
View Article and Find Full Text PDFWe propose a tool-use model that enables a robot to act toward a provided goal. It is important to consider features of the four factors; tools, objects actions, and effects at the same time because they are related to each other and one factor can influence the others. The tool-use model is constructed with deep neural networks (DNNs) using multimodal sensorimotor data; image, force, and joint angle information.
View Article and Find Full Text PDFFor the safety, underground facilities are required to be inspected regularly, especially with image analysis. Traditional wireless and wired transmission techniques have a weakness of limited transmission range in narrow underground environments. In this study, a new image transmission method based on visible light communication (VLC) has been thus proposed.
View Article and Find Full Text PDFControlling minimum toe clearance (MTC) is considered an important factor in preventing tripping. In the current study, we investigated modifications of neuro-muscular control underlying toe clearance during steady locomotion induced by repeated exposure to tripping-like perturbations of the right swing foot. Fourteen healthy young adults (mean age 26.
View Article and Find Full Text PDFGait phase detection, which detects foot-contact and foot-off states during walking, is important for various applications, such as synchronous robotic assistance and health monitoring. Gait phase detection systems have been proposed with various wearable devices, sensing inertial, electromyography, or force myography information. In this paper, we present a novel gait phase detection system with static standing-based calibration using muscle deformation information.
View Article and Find Full Text PDFThis paper presents major improvements to a multimodal, adjustable sensitivity skin sensor module. It employs a geomagnetic 3-axis Hall effect sensor to measure changes in the position of a magnetic field generated by an electromagnet. The electromagnet is mounted on a flexible material, and different current values can be supplied to it, enabling adjustments to the sensitivity of the sensor during operation.
View Article and Find Full Text PDFAppl Bionics Biomech
August 2019
The adaptive control of gait training robots is aimed at improving the gait performance by assisting motion. In conventional robotics, it has not been possible to adjust the robotic parameters by predicting the toe motion, which is considered a tripping risk indicator. The prediction of toe clearance during walking can decrease the risk of tripping.
View Article and Find Full Text PDFSoft resistive tactile sensors are versatile devices with applications in next-generation flexible electronics. We developed a novel type of soft resistive tactile sensor called a soft magnetic powdery sensor (soft-MPS) and evaluated its response characteristics. The soft-MPS comprises ferromagnetic powder that is immobilized in a liquid resin such as polydimethylsiloxane (PDMS) after orienting in a magnetic field.
View Article and Find Full Text PDFThe gas pipeline requires regular inspection since the leakage brings damage to the stable gas supply. Compared to current detection methods such as destructive inspection, using pipeline robots has advantages including low cost and high efficiency. However, they have a limited inspection range in the complex pipe owing to restrictions by the cable friction or wireless signal attenuation.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
Powered prostheses with low degree of freedom (DoF) have been developed for people with disabilities to assist daily tasks. These prostheses neglect the user's compensatory movements caused by the low degree of freedom. We assume that the movements can be reduced by well-designed controller of the devices.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
July 2018
Prediction of minimum toe clearance (MTC) during walking can decrease the risk of tripping. In this paper, we proposed a novel MTC prediction method using a radial basis function network. Input data were the angles, angular velocities, and angular accelerations of the hip, knee, and ankle joints in the sagittal plane at the start of the swing phase.
View Article and Find Full Text PDFStatic stretching is widely performed to decrease muscle tone as a part of rehabilitation protocols. Finding out the optimal duration of static stretching is important to minimize the time required for rehabilitation therapy and it would be helpful for maintaining the patient's motivation towards daily rehabilitation tasks. Several studies have been conducted for the evaluation of static stretching; however, the recommended duration of static stretching varies widely between 15-30 s in general, because the traditional methods for the assessment of muscle tone do not monitor the continuous change in the target muscle's state.
View Article and Find Full Text PDFGait training robots are useful for changing gait patterns and decreasing risk of trip. Previous research has reported that decreasing duration of the assistance or guidance of the robot is beneficial for efficient gait training. Although robotic intermittent control method for assisting joint motion has been established, the effect of the robot intervention timing on change of toe clearance is unclear.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2016
Elderly people are at risk of tripping because of their narrow range of articular motion. To avoid tripping, gait training that improves their range of articular motion would be beneficial. In this study we propose a gait-training robot that applies a torque during the pre-swing phase to achieve this goal.
View Article and Find Full Text PDFThis paper presents an easy means to produce a 3-axis Hall effect-based skin sensor for robotic applications. It uses an off-the-shelf chip and is physically small and provides digital output. Furthermore, the sensor has a soft exterior for safe interactions with the environment; in particular it uses soft silicone with about an 8 mm thickness.
View Article and Find Full Text PDFIndoor positioning remains an open problem, because it is difficult to achieve satisfactory accuracy within an indoor environment using current radio-based localization technology. In this study, we investigate the use of Indoor Messaging System (IMES) radio for high-accuracy indoor positioning. A hybrid positioning method combining IMES radio strength information and pedestrian dead reckoning information is proposed in order to improve IMES localization accuracy.
View Article and Find Full Text PDFIEEE Trans Neural Netw Learn Syst
April 2017
We suggest that different behavior generation schemes, such as sensory reflex behavior and intentional proactive behavior, can be developed by a newly proposed dynamic neural network model, named stochastic multiple timescale recurrent neural network (S-MTRNN). The model learns to predict subsequent sensory inputs, generating both their means and their uncertainty levels in terms of variance (or inverse precision) by utilizing its multiple timescale property. This model was employed in robotics learning experiments in which one robot controlled by the S-MTRNN was required to interact with another robot under the condition of uncertainty about the other's behavior.
View Article and Find Full Text PDFA hyperbolic positioning method with antenna arrays consisting of proximately-located antennas and a multi-channel pseudolite is proposed in order to overcome the problems of indoor positioning with conventional pseudolites (ground-based GPS transmitters). A two-dimensional positioning experiment using actual devices is conducted. The experimental result shows that the positioning accuracy varies centimeter- to meter-level according to the geometric relation between the pseudolite antennas and the receiver.
View Article and Find Full Text PDFIEEE Int Conf Rehabil Robot
June 2013
This paper introduces the design, fabrication and evaluation of the second generation prototype of a magnetic resonance compatible finger rehabilitation robot. It can not only be used as a finger rehabilitation training tool after a stroke, but also to study the brain's recovery process during the rehabilitation therapy (ReT). The mechanical design of the current generation has overcome the disadvantage in the previous version[13], which can't provide precise finger trajectories during flexion and extension motion varying with different finger joints' torques.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2013
The purpose of this paper is to propose noninvasive internal bleeding detection method by using ultrasound (US) image processing under US cross-section image. In this study, we have developed a robotic system for detecting internal bleeding based on the blood flow measured by using a noninvasive modality like an US imaging device. Some problems related to the measurement error, however, still need to be addressed.
View Article and Find Full Text PDFAnnu Int Conf IEEE Eng Med Biol Soc
August 2013
The purpose of this paper is to propose an organ boundary determination method for detecting internal bleeding. Focused assessment with sonography for trauma (FAST) is important for patients who are sent into shock by internal bleeding. However, the FAST has a low sensitivity, approximately 42.
View Article and Find Full Text PDF