Purpose: Oxygen delivery (DO) and its monitoring are highlighted to aid postoperative goal directed therapy (GDT) to improve perioperative outcomes such as acute kidney injury (AKI) after high-risk cardiac surgeries associated with multiple morbidities and mortality. However, DO monitoring is neither routine nor done postoperatively, and current methods are invasive and only produce intermittent DO trends. Hence, we proposed a novel algorithm that simultaneously integrates cardiac output (CO), hemoglobin (Hb) and oxygen saturation (SpO) from the Edwards Life Sciences ClearSight System® and Masimo SET Pulse CO-Oximetry® to produce a continuous, real-time DO trend.
View Article and Find Full Text PDFCongenitally corrected transposition of great arteries (ccTGA) is a rare congenital heart disease, and little literature is available that describes its anaesthetic management. We present the perioperative management of a patient with complex, cyanotic ccTGA who underwent electrophysiological study with catheter ablation under general anaesthesia. Good understanding of the patient's complex cardiac anatomy and physiology and multidisciplinary communication are vital to facilitate the successful care of the patient.
View Article and Find Full Text PDF