The ability to accurately analyze perfluoroalkyl substance (PFAS) levels in beef is imperative in order to effectively assess food-safety risks and ensure consumer safety because PFASs are harmful and prevalent in beef. In this study, we developed a rapid and accurate method for the simultaneously determination of the 17 PFASs in beef using dispersive solid-phase extraction (d-SPE) and ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), and optimized the mobile phase system, extraction solvent, and d-SPE materials. Samples were finally extracted using 0.
View Article and Find Full Text PDFAn effective method has been developed for the simultaneous determination of four bisphenols (bisphenol A, S, F and B) in various foodstuffs. The contaminants were extracted by QuEChERS-based strategy and subjected to ion-exchange solid-phase extraction for further clean-up. The critical variables were screened by Plackett-Burman design and then optimized by central composite design.
View Article and Find Full Text PDFThis article has been retracted at the request of the Editor after the corresponding author pointed the Editor to comments from an anonymous reader. The article reports electron micrographs of different preparations while showing identical images as used in previous publications by the same authors. The particles in Fig.
View Article and Find Full Text PDFBimetallic oxide CuFeO as a new heterogeneous catalyst has shown much higher catalytic ability for activating peroxide than single-metal oxides. The present work demonstrated a synergistic microwave (MW) enhanced Fenton-like process with CuFeO for rapid decolorization of azo dye Orange G (OG). The MW irradiation dramatically enhanced the OG degradation efficiency, achieving 99.
View Article and Find Full Text PDFA planar graphene oxide-based magnetic ionic liquid nanomaterial (PGO-MILN) was synthesized. The prepared PGO-MILN was characterized by transmission electronmicroscopy (TEM) and Fourier-transform infrared spectrometry (FTIR). The results of adsorption experiments showed that the PGO-MILN had great adsorption capacity for 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP).
View Article and Find Full Text PDFA new facile, rapid, inexpensive, and sensitive method for the analysis of six trace trichlorophenols in seawater samples was developed by magnetic micro-solid-phase extraction coupled to liquid chromatography with tandem mass spectrometry. Core-shell covalently functionalized ferroferric oxide coated with aminated silicon dioxide and decorated with multiwalled carbon nanotubes was applied as an adsorbent to perform the extraction process. The effect of factors including solution pH, contact time, adsorbent amount, and ionic strength were investigated in detail.
View Article and Find Full Text PDFBackground: Weight-based dosing strategy is still challenging due to poor awareness and adherence. It is necessary to let clinicians know of the latest developments in this respect and the correct circumstances in which weight-based dosing is of clinical relevance.
Methods: A literature search was conducted using PubMed.
Safe medication management and use of high-alert narcotics should arouse concern. Risk management experiences in this respect in a large-scale Joint Commission International (JCI)-accredited academic medical center hospital in the People's Republic of China during 2011-2015, focusing on organizational, educational, motivational, and information technological measures in storage, prescribing, preparing, dispensing, administration, and monitoring of medication are summarized. The intensity of use of meperidine in hospitalized patients in 2015 was one-fourth that in 2011.
View Article and Find Full Text PDFIn this study, graphene oxide-encapsulated core-shell magnetic microspheres (GOE-CS-MM) were fabricated by a self-assemble approach between positive charged poly(diallyldimethylammonium) chloride (PDDA)-modified Fe3O4@SiO2 and negative charged GO sheets via electrostatic interaction. The as-prepared GOE-CS-MM was carefully characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), vibrating sample magnetometer analysis (VSM), and X-ray photoelectron spectroscopy (XPS), and was used as a cleanup adsorbent in magnetic solid-phase extraction (MSPE) for determination of 15 trace-level environmental phenols in seafood coupled to liquid chromatography-tandem mass spectrometry (LC-MS/MS). The obtained results showed that the GOE-CS-MM exhibited excellent cleanup efficiency and could availably reduce the matrix effect.
View Article and Find Full Text PDFA novel triethylenetetramine-functionalized magnetic graphene oxide composite was prepared and used as a magnetic solid-phase extraction adsorbent for the fast detection of ten trace-level phenolic environmental estrogens in environmental water. The synthesized material was carefully characterized by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and X-ray photoelectron spectroscopy to confirm the structure and components. The adsorption and desorption conditions of the adsorbent toward phenolic environmental estrogens were optimized in detailed to obtain the best extraction recovery and elution efficiency.
View Article and Find Full Text PDFMicrocystins (MCs), a group of cyclic heptapeptide heaptoxins and tumor promoters, are generated by cyanobacteria occurring in surface waters, such as eutrophic lakes, rivers, and reservoirs. In this present study, a novel double-sided magnetic molecularly imprinted polymer modified graphene oxide (DS-MMIP@GO) based magnetic solid-phase extraction (MSPE) method was developed for fast, effective and selective enrichment, and recognition of trace MCs in environmental water samples combined with high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). The synthesized novel DS-MMIP@GO was used as the adsorbents in this work and was carefully characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FTIR), and Raman spectra.
View Article and Find Full Text PDFThe easiness-to-handle of the magnetic dispersive solid phase extraction (Mag-dSPE) procedure was developed for preconcentration of 24 steroid hormones in river water. Ethylenediamine-functionalized magnetic carbon nanotubes (EDA@Mag-CNTs) were synthesised by a simple one-pot reaction and were used as sorbent in Mag-dSPE procedure. The properties of the EDA@Mag-CNTs were characterized by transmission electron microscopy (TEM) and vibrating sample magnetometer (VSM).
View Article and Find Full Text PDFA novel planar-structure amine-functional magnetic polymer modified graphene oxide nanocomposite (NH2-MP@GO) was synthesized. The properties were characterized by transmission electron microscopy (TEM) and Fourier-transform infrared spectrometry (FTIR). The obtained adsorption results showed that the NH2-MP@GO had great adsorptive ability toward five chlorophenols (CPs), including 2-chlorophenol (2-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), 2,3,4,6-tetrachlorophenol (2,3,4,6-TeCP) and pentachlorophenol (PCP).
View Article and Find Full Text PDFA novel, simple and sensitive method based on the use of magnetic dispersive solid-phase extraction (M-dSPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) was developed to determine seven synthetic pigments (tartrazine, amaranth, carmine, sunset yellow, allura red, brilliant blue and erythrosine) in wines and soft drinks. An amino-functionalized low degrees of cross-linking magnetic polymer (NH2-LDC-MP) was synthesized via suspension polymerization, and characterized by transmission electron microscopy (TEM). The NH2-LDC-MP was used as the M-dSPE sorbent to remove the matrix from the solution, and the main factors affecting the extraction were investigated in detail.
View Article and Find Full Text PDFA novel, simple and sensitive method was developed for the simultaneous determination of 22 sulfonamides (SAs) in chicken breast muscle by using the dispersive micro-solid-phase extraction (d-μ-SPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS). The excellent core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer (CS-NR-Mag-MIP) was used as sorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.
View Article and Find Full Text PDFA novel, simple and sensitive method was developed for the simultaneous determination of eight phenolic environmental estrogens in blood by using the dispersive micro-solid-phase extraction (d-µ-SPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS). The excellent nanomaterials tetraethylenepentamine-functionalized magnetic polymer was used as an adsorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.
View Article and Find Full Text PDFA reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in red wine.
View Article and Find Full Text PDFA series of ethylenediamine (EDA)-functionalized magnetic polymers (EDA-MPs) have been prepared via suspension polymerization with the usage amount of the functional monomer glycidylmethacrylate (GMA) varied during the suspension polymerization procedure. The EDA-MPs were characterized by transmission electron microscopy (TEM), vibrating sample magnetometer (VSM), X-ray diffractometer (XRD), thermogravimetry and differential thermogravimetry analysis (TG-DTA), Fourier-transformed infrared spectroscopy (FTIR) and elementary analyzer (EA). The adsorption properties of the EDA-MPs for the removal of Cr(VI) in wastewater were deeply studied.
View Article and Find Full Text PDF