Publications by authors named "Shaun Baggarley"

Recent technological advances have allowed the possibility of performing patient-specific quality assurance (QA) without time-intensive measurements. The objectives of this study are to: (1) compare how well the log file-based Mobius QA system agrees with measurement-based QA methods (ArcCHECK and portal dosimetry, PD) in passing and failing plans, and; (2) evaluate their error sensitivities. To these ends, ten phantom plans and 100 patient plans were measured with ArcCHECK and PD on VitalBeam, while log files were sent to Mobius for dose recalculation.

View Article and Find Full Text PDF

Entrance and exit doses are commonly measured in in vivo dosimetry for comparison with expected values, usually generated by the treatment planning system (TPS), to verify accuracy of treatment delivery. This report aims to evaluate the accuracy of six TPS algorithms in computing entrance and exit doses for a 6 MV beam. The algorithms tested were: pencil beam convolution (Eclipse PBC), analytical anisotropic algorithm (Eclipse AAA), AcurosXB (Eclipse AXB), FFT convolution (XiO Convolution), multigrid superposition (XiO Superposition), and Monte Carlo photon (Monaco MC).

View Article and Find Full Text PDF

Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies.

View Article and Find Full Text PDF

Background: To determine the usefulness of ultrasonography in the assessment of post radiotherapy skin changes in postmastectomy breast cancer patients.

Methods: Patients treated for postmastectomy radiotherapy in National University Hospital (NUH) and Tan Tock Seng Hospital (TTSH), Singapore between January 2004- December 2005 was recruited retrospectively. Ultrasound scan was performed on these Asian patients who had been treated to a total dose of 46-50 Gy with 1 cm bolus placed on the skin.

View Article and Find Full Text PDF

Introduction: This study aims to assess the early tumour outcome and morbidity associated with radiation therapy (RT) in tumours of the central nervous system (CNS).

Materials And Methods: Patients receiving RT with radical intent were entered on a prospective database. Tumour types were categorised into glioma, base of skull, pituitary, germ cell or primitive neuroectodermal tumour (PNET) and other malignant CNS tumours.

View Article and Find Full Text PDF