Background: Although many surgeons use absorbable sutures for skin closure of 5-mm trocar sites, effective alternative materials exist. We compared 5-mm trocar site closures using a vicryl suture (VS), cyanoacrylate tissue adhesive (CTA), or skin tape (ST).
Methods: Patients rated wound pain and appearance at 1 and 6 weeks after surgery.
J Laparoendosc Adv Surg Tech A
February 2002
Background And Purpose: The extent of lateral spread of tissue injury is important in the success of a primary anastomosis. We compared the injury produced by the Laparo-sonic Coagulation Shears and the Ligasure system.
Materials And Methods: Ureters were harvested from domestic farm pigs and ligated with the Laparo-sonic (N = 13) or Ligasure (N = 9) system.