Subclavian artery aneurysms are rare and can result in thromboembolism or rupture. We present the case of a 41-year-old man with a history of Marfan's syndrome and multiple previous operations, who presented with an enlarging asymptomatic 5.2 cm right subclavian artery aneurysm and was successfully treated with a hybrid surgical operation.
View Article and Find Full Text PDFBackground: Since its recognition as an independent surgical subspecialty, vascular surgery has experienced rapid growth in both surgical volume and research productivity. Trends in vascular surgery research have not been well characterized. Understanding how research in the field has evolved in comparison to interventional radiology can offer insights into evolving interests and discrepancies between the specialties.
View Article and Find Full Text PDFBackground: Hybrid debranching repair of pararenal and thoracoabdominal aortic aneurysms was initially designed as a better alternative to standard open repair, addressing the limitations of endovascular repair involving the visceral aorta. We reviewed the collective outcomes of hybrid debranching repairs using extra-anatomic, open surgical debranching of the renal-mesenteric arteries, followed by endovascular aortic stenting.
Methods: Data from patients who underwent hybrid repair in 14 North American institutions during 10 years were retrospectively reviewed.
Objective: Spinal cord injury (SCI) is one of the most devastating complications of thoracoabdominal aortic aneurysm (TAAA) repair. Cerebrospinal fluid drainage (CSFD) is routinely used to prevent and to treat SCI during open TAAA repair. However, the risks and benefits of CSFD during fenestrated-branched endovascular aneurysm repair (F/B-EVAR) are unclear.
View Article and Find Full Text PDFBackground: Transplant renal artery stenosis (TRAS) is a serious complication associated with graft loss. Selective carbon dioxide angiography allows for effective diagnosis and therapy with the use of minimal to no contrast agent. This study sought to evaluate the efficacy of the adjunctive use of carbon dioxide angiography in the treatment of TRAS.
View Article and Find Full Text PDFBackground: The aim of this study is to evaluate the safety and effectiveness of percutaneous axillary artery access in patients requiring upper extremity large sheath access during complex aortic interventions.
Methods: Consecutive patients who had percutaneous axillary artery access with a large-bore sheath during endovascular thoracoabdominal aortic artery aneurysm repair within an Food and Drug Administration-approved, physician-sponsored investigational device exemption study or visceral artery interventions during other complex aortic interventions were included in the study. All patients had percutaneous axillary artery ultrasound-guided access and deployment of 2 Perclose ProGlide devices (Abbott Vascular, Santa Clara, CA) prior to introduction of a large sheath.
Background: Retrograde arterial access (RA) of the popliteal, tibial, or pedal arteries may facilitate endovascular treatment of complex infrainguinal lesions in patients with critical limb ischemia (CLI). Here, we assess the safety and efficacy of this technique.
Methods: A retrospective review of prospectively collected institutional data (consecutive M2S entries) was performed to identify patients with CLI undergoing peripheral vascular intervention from February 2012 through December 2017.
Objectives: Upper extremity arterial access is often required for endovascular procedures, especially for antegrade access to the visceral aortic branches. Radial arterial access has been shown previously to have low complication rates, and patients tolerate the procedure well and are able to recover quickly. However, transradial access remains relatively uncommon amongst vascular surgeons.
View Article and Find Full Text PDFObjective: To evaluate the outcomes and learning curve of fenestrated and branched endovascular repair (F/BEVAR) of thoracoabdominal aneurysms.
Summary Of Background Data: Endovascular aneurysm repair has reduced morbidity and mortality compared with open surgical repair. However, application to thoracoabdominal aneurysm repair remains limited by procedural complexity and device availability.
Purpose: Inferior vena cava filters (IVCFs) are often placed for prophylactic indications. We sought to better define the range of practice indications for placement of prophylactic IVCFs, as well as the specific retrieval rate and risk factors for nonretrieval.
Methods: A retrospective, single-institution review of patients undergoing IVCF placement over a 2-year period was performed.
Vasc Endovascular Surg
October 2017
Transradial access has been described in a variety of clinical contexts but has been rarely utilized for visceral artery interventions and during complex endovascular aortic aneurysm repair (EVAR) when upper extremity access is required. This is usually accomplished via brachial artery access, and although brachial access is generally safe and effective, radial access may offer some benefits with regard to patient comfort and potential complications. Here we report a case of successful delivery of a renal snorkel via a radial artery approach during EVAR.
View Article and Find Full Text PDFObjective: Endovascular treatment of thoracoabdominal aortic aneurysms (TAAAs) with branched and fenestrated stent grafts often requires upper extremity arterial access for antegrade delivery of bridging covered stents into the visceral arteries. Axillary, brachial, and radial artery approaches have been described, but data on the safety and utility of the different approaches remain limited. We have preferentially used axillary artery conduits for upper extremity arterial access during endovascular repair of TAAA and describe our technique and report our experience herein.
View Article and Find Full Text PDFObjective: The objective of this study was to review the current anatomic indications for and early results of aortouni-iliac (AUI) devices for endovascular aneurysm repair.
Methods: A total of 128 patients receiving an Endurant (Medtronic Inc, Minneapolis, Minn) AUI device in the U.S.
Purpose: To examine the safety and efficacy of the SpiderFX embolic protection device (EPD) in the below-the-knee (BTK) circulation in patients with critical limb ischemia (CLI).
Materials And Methods: A single-center retrospective review was performed to identify patients with CLI and single-vessel runoff in whom the SpiderFX EPD was used in the BTK circulation. Technical success and device-related complications were the primary endpoints.
Cervical-petrous internal carotid artery (CP-ICA) pseudoaneurysms are rare and have different etiologies, presentations, and treatment options. A middle-aged patient with a history of chronic otitis media presented with acute otorrhagia and was found to have a left-sided CP-ICA pseudoaneurysm. The patient was a poor surgical candidate with difficult arterial access.
View Article and Find Full Text PDFCervical-petrous internal carotid artery (CP-ICA) pseudoaneurysms are rare and have different etiologies, presentations, and treatment options. A middle-aged patient with a history of chronic otitis media presented with acute otorrhagia and was found to have a left-sided CP-ICA pseudoaneurysm. The patient was a poor surgical candidate with difficult arterial access.
View Article and Find Full Text PDFEndovascular aneurysm repair is now the preferred method of abdominal and thoracic aneurysm repair. Until recently, the limitation with this technology has been preservation of the visceral vasculature, hypogastric arteries, and the great vessels. The Zenith® Fenestrated (Cook, Bloomington, IN) is the first device available for use in the US for treatment of para-renal or juxta-renal aneurysms.
View Article and Find Full Text PDFObjective: There have been four eras in the development of endovascular aneurysm repair (EVAR): physician-made grafts, early industry devices, intermediary commercial endografts, and modern stent grafts. This study analyzes differences in outcomes between these four groups and the impact of device evolution and increased physician experience.
Methods: From 1992 to 2012, 1380 patients underwent elective EVAR.
Background: This study investigates the impact of sex on angioplasty and primary stenting for the treatment of claudicants with femoropopliteal occlusive disease (FPOD).
Methods: Two hundred eighty-seven patients enrolled in the Safety and Effectiveness Study of EverFlex Stent to Treat Symptomatic Femoral-popliteal Atherosclerosis (DURABILITY II) trial (a prospective, nonrandomized, core laboratory audited, and independently adjudicated investigational device exemption trial) were stratified by sex (190 men and 97 women) and reviewed.
Results: Women presented with FPOD at an older age than men (71.
Purpose: We describe the anatomic characteristics on preoperative CT angiography (CTA) that predispose to type-2 endoleaks after endovascular aneurysm repair (EVAR) for an abdominal aortic aneurysms (AAA).
Methods: Between 1999 and 2010, 326 patients had a CTA before and after EVAR. CTAs were reviewed for maximal sac diameter, >50% circumferential luminal thrombus, and patency of the infrarenal aortic side branches, including the inferior mesenteric artery (IMA) and L2-L5 lumbar arteries.
A 47-year-old woman with a mechanical mitral valve underwent a catheter-based atrial fibrillation ablation procedure, which was complicated by the dislodgment and immediate embolization of one of the valve leaflets. Acute severe mitral regurgitation and cardiogenic shock developed, necessitating emergency reoperative mitral valve re-replacement. She subsequently underwent a successful staged retrieval of the embolized leaflet from the abdominal aorta.
View Article and Find Full Text PDFBackground: After open thoracic and thoracoabdominal aortic aneurysm repair, anastomotic aneurysms can form at or near the suture lines of the graft. Endovascular repair is an alternative to complicated reoperative open surgery. We report on our experience with endovascular treatment of these lesions.
View Article and Find Full Text PDFThe paradigm in elective surgical management of infrarenal abdominal aortic aneurysms (AAAs) has quickly shifted from major open surgical repairs to less invasive, endovascular procedures. In the last few years, there have been numerous advancements to commercially available devices making the endovascular approach more attractive and efficacious. This review serves to detail the similarities, differences, advantages, and disadvantages of currently available endovascular stent-grafts as well as preview future and emerging technologies in endovascular aortic therapies.
View Article and Find Full Text PDFPurpose: To review the effect of preoperative embolization of the inferior mesenteric artery (IMA) before endovascular aneurysm repair (EVAR) on subsequent endoleaks and aneurysm growth.
Materials And Methods: Between August 2002 and May 2010, 108 patients underwent IMA embolization before EVAR. Coil embolization was performed in all patients in whom the IMA was successfully visualized and accessed during preoperative conventional angiography.
Background: Statin use results in atherosclerotic plaque stabilization. We sought to determine the effects of statins on the size and number of embolic particles generated during carotid artery stenting (CAS).
Methods: Embolic debris from carotid filters following CAS was analyzed using photomicroscopy and imaging software.