Neurodegenerative diseases, such as Alzheimer's disease (AD), are characterized by massive loss of specific neurons. It is a progressive disabling, severe and fatal complex disease. Due to its complex pathogenesis and limitations of clinical treatment strategies, it poses a serious medical challenge and medical burden worldwide.
View Article and Find Full Text PDFZhonghua Wei Zhong Bing Ji Jiu Yi Xue
March 2023
Objective: To compare the effect and safety of continuous veno-venous hemofiltration (CVVH)+double plasma molecular absorption (DPMA)+hemoperfusion (HP), CVVH+HP, and CVVH+plasma exchange (PE) in treatment of patient with severe wasp stings injury.
Methods: Multicenter, historical cohort study and superiority test were used. From July 2020 to October 2022, patients with wasp sting injury and multiple organ damage admitted to the intensive care units (ICU) of five hospitals were consecutively screened and recruited into the CVVH+DPMA+HP group (intervention group).
Background: To explore whether salivary inflammatory mediators and periodontal indices at different gestational stages can be taken as indicators of preterm birth (PTB).
Methods: This nested case-control study enrolled systemically healthy pregnant women at 9 to 36 weeks of gestation. Periodontal indices were measured at the enrollment date, and interleukin-1 (IL-1), IL-6, tumor necrosis factor (TNF-), prostaglandin E2 (PGE2), and 8-hydroxy-deoxyguanosine (8-OHdG) in the saliva were determined by enzyme-linked immunosorbent assay (ELISA).
A novel method for power-in-the-bucket (PIB) measurement of high power laser beams is proposed. The laser beam spot was first sampled by a rotating involute pinhole array and then collected by using a photodetector placed behind the pinholes. The spatial-temporal distribution and calibrated PIB curve of the laser beam can be obtained.
View Article and Find Full Text PDFObjectives: This study aimed to investigate the association between periodontal indexes and biomarkers in gingival crevicular fluid (GCF) and preterm birth (PTB) in pregnancy, as well as to assess the clinical value of these indexes as predictors of PTB.
Methods: A nested case-control study was conducted. A total of 300 systematically healthy pregnant women were selected within 36 weeks of gestation and grouped according to the enrolled weeks.
This paper presents a special design of a new kind of silicon nitride/titanium oxide hybrid waveguide with multi-layer materials laminate structure aiming at broadband athermal operation. By incorporating three layers of titanium oxide whose thermo-optic coefficient (TOC) is negative in the waveguide core and upper cladding regions, the thermal drift of the conventional strip waveguide induced by the positive TOC of silicon nitride is fully compensated, with the effective TOC of the hybrid waveguide achieving zero at 1550 nm and only varying extremely slightly within ±6×10/K in the wavelength band from 1350 to 1850 nm. In addition, due to the inherent alternate growth manner of titanium dioxide and silicon nitride thin layers, this new kind of multi-layer material laminate structure waveguide holds the potential of avoiding the challenging growth of low-stress crack-free single-layer silicon nitride film thick enough for realizing an anomalous dispersion waveguide.
View Article and Find Full Text PDFWe numerically simulate Kerr comb generation in an anomalous dispersion microcavity by modal expansion method and demonstrate that the initiation of comb generation is affected by the change of local dispersion possibly caused by avoided mode crossings. We also quantitatively analyze the instantaneous phase matching of different modes and reveal the characteristics of energy distribution in different modes in the dynamics of comb generation. We demonstrate that the local dispersion change can control the Kerr comb to transform between Type I and Type II combs.
View Article and Find Full Text PDFAn asymmetric strip/slot hybrid silicon nitride waveguide is designed to simultaneously realize athermal operation and flat dispersion. The slot filling and upper cladding materials are negative thermal-optical coefficient (TOC), low refractive index polyurethane acrylate, while the left and right cladding layers are positive TOC, high refractive index silicon nitride. With suitable waveguide parameter selection, an optimum strip/slot hybrid silicon nitride waveguide exhibits an effective TOC of 1.
View Article and Find Full Text PDFHormones (progesterone and estradiol) change greatly during pregnancy; however, the mechanism of hormonal changes on gingival inflammation is still unclear. This study is to evaluate the effects of hormonal changes during pregnancy on gingival inflammation and interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α) in gingival crevicular fluid (GCF). 30 periodontally healthy pregnant women were evaluated in the first, second, and third trimesters.
View Article and Find Full Text PDFAn increase in the prevalence and severity of gingival inflammation during pregnancy has been reported since the 1960s. Though the etiology is not fully known, it is believed that increasing plasma sex steroid hormone levels during pregnancy have a dramatic effect on the periodontium. Current works of research have shown that estrogen and progesterone increasing during pregnancy are supposed to be responsible for gingivitis progression.
View Article and Find Full Text PDFComput Methods Biomech Biomed Engin
February 2016
Few studies are performed to evaluate the influence of connection type on the stress distribution of distal extension mandibular removable partial dentures (RPDs) supported by both implants and natural teeth. In this study, five three-dimensional finite element models were prepared to simulate mandibular bilateral partially edentulous arches. Four were RPDs supported by both implants and natural teeth, and the other one was RPDs supported only by natural teeth.
View Article and Find Full Text PDFThis preliminary study evaluated the adjunctive supporting role of diverse implant positions on stress distribution in a Class I removable partial denture (RPD) design. Nine three-dimensional finite element models were prepared to simulate mandibular RPD designs with three different loading conditions applied. Implant supported designs demonstrated lower stress value concentrations and mucosal displacement.
View Article and Find Full Text PDFWe have developed a silicon depletion-mode modulator featuring a novel U-type PN junction that enables a substantial improvement in electro-optical modulation efficiency. Through electrical, optical, and manufacturing process simulations, an ultralow VL of 0.63 V·cm is exhibited with 3 V reverse bias.
View Article and Find Full Text PDFWe propose and analyze a polarization rotator based on a bend asymmetric-slab waveguide on the silicon-on-insulator platform. The device can be fabricated using standard complementary metal-oxide-semiconductor process involving only two dry etching steps. Compared with the formerly reported polarization rotators based on two-step etching, our introduced device demonstrates a significant improvement for fabrication tolerance.
View Article and Find Full Text PDFAn ultracompact polarization splitter-rotator based on an asymmetric directional coupler has been designed and analyzed. The device consists of one channel waveguide and one vertical slot waveguide, which couple to each other to form the asymmetric directional coupler. The coupling length is only 17.
View Article and Find Full Text PDFBistability (BS) and self-pulsation (SP) phenomena in silicon microring resonators (MRR) with intense CW light injection are studied. Several nonlinear optical effects including Kerr effect, two-photon absorption, free carrier absorption and free carrier dispersion are taken into account. The threshold optical intensity of BS and SP is derived from the coupled mode theory and a linear stability analysis method.
View Article and Find Full Text PDFJ Nanosci Nanotechnol
February 2009
We report on the design and fabrication of a photonic crystal (PC) channel drop filter based on an asymmetric silicon-on-insulator (SOI) slab. The filter is composed of two symmetric stick-shape micro-cavities between two single-line-defect (W1) waveguides in a triangular lattice, and the phase matching condition for the filter to improve the drop efficiency is satisfied by modifying the positions and radii of the air holes around the micro-cavities. A sample is then fabricated by using electron beam lithography (EBL) and inductively coupled plasma (ICP) etching processes.
View Article and Find Full Text PDFOpt Express
September 2007
A novel on-line beam diagnostic method for continuous-wave high energy laser (HEL) is presented. The system based on this method is mainly consisted of a scanning circular reflector and a photodetector array disposed spatially. Laser beam passes through the system except a little part of whole beam is sampled and reflected into the detector array by the circular reflector.
View Article and Find Full Text PDFThe identification, optimization, and structure-activity relationship (SAR) of small-molecule CCR4 antagonists is described. An initial screening hit with micromolar potency was identified that was optimized to sub-micromolar binding potency by enantiomer resolution, halogenation of the naphthalene ring, and extension of the alkyl chain linker between the central piperidine ring and the terminal aryl group. An antagonist was identified that showed good cross-reactivity against the mouse receptor and inhibited CCR4-based cell recruitment in dose-dependent fashion.
View Article and Find Full Text PDFA rearrangeable nonblocking silicon-on-insulator-based thermo-optic 4x4 switch matrix is designed and fabricated. A spot-size converter is integrated to reduce the insertion loss, and a new driving circuit is designed to improve the response speed. The insertion loss is less than 10 dB, and the response time is 950 ns.
View Article and Find Full Text PDF