Cardiovascular pressure sensors require dedicated, reliable, and customisable performance testing equipment. Devices available on the market, such as pulsatile pumps and pulse multipliers, offer limited adaptability to the needs of pressure sensor testing or are highly complex tools designed for other purposes. Therefore, there is a strong need to provide an adaptable and versatile device for characterisation during prototype development, prior to animal model testing.

View Article and Find Full Text PDF

Background: Independent testing of home blood pressure (BP) measurement (HBPM) devices is often lacking, particularly among older and multi-morbid patients.

Methods: We studied the Bpro G2 (using tonometry), Omron HeartGuide (using occlusive oscillometric technology), and Heartisans (using photoplethysmography) wrist watch HBPM devices against a gold standard brachial sphygmomanometer. To test device performance, we used the ISO81060-2 protocol (though this protocol cannot formally validate cuffless devices).

View Article and Find Full Text PDF

Objectives: To develop and assess a system for shared ventilation using clinically available components to individualize tidal volumes.

Design: Evaluation and in vitro validation study SETTING: Ventilator shortage during the SARS-CoV-2 pandemic.

Participants: The team consisted of physicians, bioengineers, computer programmers, and medical technology professionals.

View Article and Find Full Text PDF

Cardiac wireless implantable medical devices (CWIMD) have brought a paradigm shift in monitoring and treating various cardiac conditions, including heart failure, arrhythmias, and hypertension. One of the key elements in CWIMD is the implant antenna which uses radio frequency (RF) technology to wirelessly communicate and transmit data to external devices. However, wireless communication with a deeply implanted antenna using RF can be challenging due to the significant loss of electromagnetic (EM) signal at the air-skin interface, and second, due to the propagation and reflection of EM waves from different tissue boundaries.

View Article and Find Full Text PDF

Wireless implantable medical devices (WIMDs) have seen unprecedented progress in the past three decades. WIMDs help clinicians in better-understanding diseases and enhance medical treatment by allowing for remote data collection and delivering tailored patient care. The wireless connectivity range between the external reader and the implanted device is considered one of the key design parameters in WIMD technology.

View Article and Find Full Text PDF

Objectives: There has been a steady increase in the number of studies of the complex relationship between glucose and electrical cardiac activity which use simultaneous continuous glucose monitors (CGM) and continuous electrocardiogram (ECG). However, data collected on the same individual tend to be similar (yielding correlated or dependent data) and require analyses that take into account that correlation. Many opt for simplified techniques such as calculating one measure from the data collected and analyse one observation per subject.

View Article and Find Full Text PDF

The wireless monitoring of key physiological parameters such as heart rate, respiratory rate, temperature, and pressure can aid in preventive healthcare, early diagnosis, and patient-tailored treatment. In wireless implantable sensors, the distance between the sensor and the reader device is prone to be influenced by the operating frequency, as well as by the medium between the sensor and the reader. This manuscript presents an ex vivo investigation of the wireless linkage between an implantable sensor and an external reader for medical applications.

View Article and Find Full Text PDF

With the recent advancements in the field of wearable technologies, the opportunity to monitor stress continuously using different physiological variables has gained significant interest. The early detection of stress can help improve healthcare and minimizes the negative impact of long-term stress. This paper reports outcomes of a pilot study and associated stress-monitoring dataset, named the "Stress-Predict Dataset", created by collecting physiological signals from healthy subjects using wrist-worn watches with a photoplethysmogram (PPG) sensor.

View Article and Find Full Text PDF

Purpose: Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method.

View Article and Find Full Text PDF

Over the past decade, there has been a significant development in wearable health technologies for diagnosis and monitoring, including application to stress monitoring. Most of the wearable stress monitoring systems are built on a supervised learning classification algorithm. These systems rely on the collection of sensor and reference data during the development phase.

View Article and Find Full Text PDF

Background: While radial stent deformation has been thoroughly investigated, data on longitudinal deformation are scarce.

Aims: The aim of the study was to describe longitudinal stent deformation associated with the proximal optimisation technique (POT).

Methods: Longitudinal stent deformation was assessed by bench testing and by clinical evaluation.

View Article and Find Full Text PDF

A novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional finite element analysis of cardiovascular biomechanics using the estimated pulsatile pressure, the 4D-SWS approach can calculate the dynamic mechanical state of the superficial wall , which could be directly linked with plaque rupture or stent fracture. The validation of this approach using models showed that the distribution and maximum values of superficial wall stress were similar to those calculated by conventional finite element analysis.

View Article and Find Full Text PDF

Stress is a known contributor to several life-threatening medical conditions and a risk factor for triggering acute cardiovascular events, as well as a root cause of several social problems. The burden of stress is increasing globally and, with that, is the interest in developing effective stress-monitoring solutions for preventive and connected health, particularly with the help of wearable sensing technologies. The recent development of miniaturized and flexible biosensors has enabled the development of connected wearable solutions to monitor stress and intervene in time to prevent the progression of stress-induced medical conditions.

View Article and Find Full Text PDF

The dielectric properties of bones are found to be influenced by the demineralisation of bones. Therefore, microwave imaging (MWI) can be used to monitor in vivo dielectric properties of human bones and hence aid in the monitoring of osteoporosis. This paper presents the feasibility analysis of the MWI device for monitoring osteoporosis.

View Article and Find Full Text PDF

Electrochemically based technologies are rapidly moving from the laboratory to bedside applications and wearable devices, like in the field of cardiovascular disease. Major efforts have focused on the biosensor component in contrast with those employed in creating more suitable detection algorithms for long-term real-world monitoring solutions. The calibration curve procedure presents major limitations in this context.

View Article and Find Full Text PDF

Physiological pressure measurement is one of the most common applications of sensors in healthcare. Particularly, continuous pressure monitoring provides key information for early diagnosis, patient-specific treatment, and preventive healthcare. This paper presents a thin-film flexible wireless pressure sensor for continuous pressure measurement in a wide range of medical applications but mainly focused on interface pressure monitoring during compression therapy to treat venous insufficiency.

View Article and Find Full Text PDF

Microwave tomography (MWT) can be used as an alternative modality for monitoring human bone health. Studies have found a significant dielectric contrast between healthy and diseased human trabecular bones. A set of diverse bone phantoms were developed based on single-pole Debye parameters of osteoporotic and osteoarthritis human trabecular bones.

View Article and Find Full Text PDF

Diagnosing and treating acute coronary syndromes consumes a significant fraction of the healthcare budget worldwide. The pressure on resources is expected to increase with the continuing rise of cardiovascular disease, other chronic diseases and extended life expectancy, while expenditure is constrained. The objective of this review is to assess if home-based solutions for measuring chemical cardiac biomarkers can mitigate or reduce the continued rise in the costs of ACS treatment.

View Article and Find Full Text PDF

The objective of this study is to determine whether in vitro dielectric properties of human trabecular bones, can distinguish between osteoporotic and osteoarthritis patients' bone samples. Specifically this study enlightens intra-patient variation of trabecular bone microarchitecture and dielectric properties, inter-disease comparison of bone dielectric properties, and finally establishes the correlation to traditional bone histomorphometry parameter (bone volume fraction) for diseased bone tissue. Bone cores were obtained from osteoporotic and osteoarthritis patients (n = 12).

View Article and Find Full Text PDF

To investigate the feasibility and efficacy of localized, subtotal, cortical-sparing microwave thermal ablation (MTA) as a potential curative management for primary aldosteronism. The study investigated with equal importance the selected ablation of small volumes of adrenal cortex while sparing adjacent cortex. An study was carried out in swine ( = 8) where MTA was applied under direct visualization, to the adrenal glands at 45 W or 70 W for 60 s, using a lateral, side-firing probe and a non-penetrative approach.

View Article and Find Full Text PDF

Background: It is known that proteins associated with Alzheimer's disease (AD) pathogenesis are significantly reduced by 40 Hz entrainment in mice. If this were to translate to humans, verifying that such a light stimulus can induce a 40 Hz entrainment response in humans and harnessing insights from these case studies could be one step in the development of a multisensory device to prevent and treat AD.

Objective: Verify the inducement of a 40 Hz response in the human brain by a 40 Hz light stimulus and obtain insights that could potentially aid in the development of a multisensory device for the prevention and treatment of AD.

View Article and Find Full Text PDF

The dielectric properties are key parameters that quantify the interaction between electromagnetic waves and human biological tissues. In particular, the development of electromagnetic-based medical technologies rely on knowledge of the dielectric properties of bone, specifically for applications such as electrical stimulation and bone health monitoring. Electrical stimulation is used in clinics to promote the healing of bone fractures, treating non-unions, congenital pseudarthrosis, bone regeneration and during bone implant procedures.

View Article and Find Full Text PDF

Osteoporosis is one of the most common diseases that leads to bone fractures. Dual-energy X-ray absorptiometry is currently employed to measure the bone mineral density and to diagnose osteoporosis. Alternatively, the dielectric properties of bones are found to be influenced by bone mineral density; hence, dielectric properties of bones may potentially be used to diagnose osteoporosis.

View Article and Find Full Text PDF

Electromagnetic (EM) medical technologies are rapidly expanding worldwide for both diagnostics and therapeutics. As these technologies are low-cost and minimally invasive, they have been the focus of significant research efforts in recent years. Such technologies are often based on the assumption that there is a contrast in the dielectric properties of different tissue types or that the properties of particular tissues fall within a defined range.

View Article and Find Full Text PDF