Publications by authors named "Shahram Riahinezhad"

The objective of this study was to improve the biomechanical performance of titanium (Ti) using a biocompatible electrospun nanofiber matrix. The study is based on the hypothesis that coating a Ti surface with a nanofiber matrix (NFM) made of collagen (CG) and polycaprolactone (PCL) electrospun nanofibers could increase the mechanical fixation of Ti/bone by improving the surface and cytocompatibility properties of Ti. This study prepared Ti samples with and without CG-PCL NFM coatings.

View Article and Find Full Text PDF

Poly(methyl methacrylate) (PMMA) bone cement has limited biocompatibility. Polycaprolactone (PCL) electrospun nanofiber (ENF) has many applications in the biomedical field due to its excellent biocompatibility and degradability. The effect of coating PCL ENF on the surface topography, biocompatibility, and mechanical strength of PMMA bone cement is not currently known.

View Article and Find Full Text PDF

The effect of depositing a collagen (CG)-poly-ε-caprolactone (PCL) nanofiber mesh (NFM) at the microgrooves of titanium (Ti) on the mechanical stability and osseointegration of the implant with bone was investigated using a rabbit model. Three groups of Ti samples were produced: control Ti samples where there were no microgrooves or CG-PCL NFM, groove Ti samples where microgrooves were machined on the circumference of Ti, and groove-NFM Ti samples where CG-PCL NFM was deposited on the machined microgrooves. Each group of Ti samples was implanted in the rabbit femurs for eight weeks.

View Article and Find Full Text PDF

Titanium (Ti) alloys have been widely used in orthopedics and orthodontic surgeries as implants because of their beneficial chemical, mechanical, and biological properties. Improvement of these properties of a Ti alloy, Ti-6Al-4V Eli, is possible by the use of plasma nitriding treatment on the Ti alloy. The novelty of this study is the evaluation of a DC glow discharge nitrogen plasma treatment method on the surface, mechanical and biological properties of Ti alloy.

View Article and Find Full Text PDF

Implant failure due to poor integration of the implant with the surrounding biomaterial is a common problem in various orthopedic and orthodontic surgeries. Implant fixation mostly depends upon the implant surface topography. Micron to nanosize circular-shaped groove architecture with adequate surface roughness can enhance the mechanical interlock and osseointegration of an implant with the host tissue and solve its poor fixation problem.

View Article and Find Full Text PDF