Determining the appropriate technique for diastema closure is challenging, and the decision must be evidence based. The objective of these case reports is to describe different approaches to diastema closure using direct and indirect techniques, focusing on the characteristics of the patient and clinical requirements to guide treatment. In the first case, a 16-year-old patient had multiple diastemas in the maxillary anterior dentition.
View Article and Find Full Text PDFObjective: This case report described the use of a stamping technique associated with a bulk fill composite to restore an ICDAS 4 carious lesion on a posterior tooth. The 4-year follow-up is also presented.
Clinical Considerations: A 32-year-old patient presented a carious lesion on tooth 36 with an underlying dark shadow at the dentin seen from the noncavitated enamel occlusal surface, which was compatible with an ICDAS 4 carious lesion.
Int J Periodontics Restorative Dent
April 2022
Teeth affected by molar incisor hypomineralization (MIH) present micromorphologic changes and hypersensitivity, which increase the risk of developing caries lesions and affect bonding procedures. Considering that practitioners still misdiagnose teeth affected by MIH, there is an urge for more knowledge about this topic in order to propose a more adequate and conservative treatment. The purpose of this study was to report the clinical challenges regarding the restorative management of a patient with MIH.
View Article and Find Full Text PDFThis study aimed to analyze the interaction of a MDP-based universal dentin bonding system (DBS) with Er, Cr: YSGG laser irradiation, measuring the microtensile bond strength to dentin over a six-month period. The experimental design involved three factors: DBS (Adper Scotchbond Universal; Clearfil SE Bond, Adper Scotchbond Multipurpose and Adper Single Bond 2), laser (Control and Er, Cr: YSGG), and time (initial- 7 days and 6 months). Eighty dentin samples from molars were prepared (n=10) with laser irradiation after primer and DBS application.
View Article and Find Full Text PDFThe present in vitro study assessed the polymerization shrinkage/PS, Knoop microhardness/KHN and depth of cure/DC of 9 different resin composites : Filtek Bulk Fill Flowable (FBF), Surefill SDR flow (SDR), Xtra Base (XB), Filtek Z350XT Flowable (Z3F), Filtek Bulk Fill Posterior (FBP), Xtra Fill (SF), Tetric Evo Ceram Bulk Fill (TBF), Admira Fusion Xtra (ADM), and Filtek Z350XT (Z3XT). PS was assessed with a µ-CT machine, scanning 64 mm samples (n=8) before and after 20 s curing. KHN and DC were performed with a microhardness tester (n=8 for each group) right after 20 s light curing, with 3 readings per depth at every 0.
View Article and Find Full Text PDFZirconia-reinforced lithium silicate (ZLS) has recently been introduced in an effort to improve the mechanical properties of glass-ceramic materials. In vitro evaluations suggest that this class of material has high flexural strength and exhibits satisfactory adhesion to resin cement and wear resistance. Since few clinical reports of this novel material are currently available, the aim of this case report is to describe clinical perceptions regarding the handling and performance of ZLS ceramics when used for laminate veneers on the maxillary incisors.
View Article and Find Full Text PDFUnlabelled: Bulk-fill composites were introduced in dentistry to accelerate clinical procedures while providing adequate outcomes. Concerns regarding the use of bigger composite increments rely on the polymerization shrinkage and shrinkage stress, which may generate gaps on the adhesive interface and result in a reduced success rate.
Objective: To evaluate the polymerization shrinkage stress of different bulk-fill resin composites and their elastic modulus.
J Appl Oral Sci
December 2018
Objectives: The aim of this in vitro study was to evaluate the bonding strength of non-simplified dentin bonding systems (DBS) to dentin irradiated with a diode laser (970 nm) immediately and after 12 months of water storage following either primer or bond application.
Material And Methods: The experimental design included three different factors: DBS type [AdperTM Scotchbond Multipurpose (MP) and Clearfil™ SE Bond (CSE)], irradiation [without irradiation - control (C), irradiation after primer application (AP), and irradiation after bond application (AB)], and time [initial (I) and after 12 months of water storage (12 m)]. Sixty sound human third molars (n = 10) were obtained, and their flat occlusal dentin areas were prepared and standardized.
Photodiagnosis Photodyn Ther
December 2018
Background: The use of hybrid-light (HL) during in-office teeth bleaching can provide faster and reliable results after a single bleaching session, especially if associated with previous acid etching. The present in vivo, interventional, split-mouth, triple-blinded and randomized study evaluated the efficiency of a HL, with and without prior enamel acid etching, assessing the gel application time, degree of color change, sensitivity and treatment stability up to 12 months.
Methods: Thirty-four patients were selected and randomly divided into four groups.
The purpose of this in vitro study was to compare the micro hardness, color stability/ΔE, and degree of conversion/DC of a resin cement light cured through different ceramic spacers. Lithium-disilicate ceramic samples were obtained from IPS E-max CAD blocks (HT A1) and IPS in-Ceram (transparent neutral); and divided in 7 groups (n = 8 for each test): CTR/control group; 06 M/0.6 mm monolithic; 12 M/1.
View Article and Find Full Text PDFDue to improvements in esthetic dentistry, the number of patients seeking to obtain a more harmonious smile has increased. A 40-year-old woman was referred for treatment because she was dissatisfied with the effect that diastemas and a conoid tooth had on her smile. Her maxillary anterior teeth were relatively short, resulting in a compromised esthetic relationship between height and width.
View Article and Find Full Text PDFObjective: This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance.
Material And Methods: Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups].
Compend Contin Educ Dent
March 2017
Often, young patients (≤30 years old) present with carious lesions that progress acutely, compromising a large amount of tooth structure. In these cases, a treatment to prevent the occurrence of pulp exposure and promote remineralization of caries-affected dentin is necessary to maintain healthy dental structure and allow more conservative interventions. The approach will be different when pulp exposure occurs: The therapeutic treatments will be focused on reparative dentin formation and prevention of microorganisms penetrating the pulp organ.
View Article and Find Full Text PDFPurpose: To evaluate the color change caused by post-irradiation conversion (ΔE and ΔE ) and artificial aging (ΔE ) of resin cements light activated through ceramics of different opacities immediately and 6 minutes after manipulating the material.
Materials And Methods: Resin cement disks (Allcem and LuxaCore) were light activated through ceramics (without ceramic, e.max HT, LT, and MO) immediately and 6 minutes after the manipulation (n = 10).
The use of light sources in the bleaching process reduces the time required and promotes satisfactory results. However, these light sources can cause an increase in the pulp temperature. Objective The purpose of the present study was to measure the increase in intrapulpal temperature induced by different light-activated bleaching procedures with and without the use of a bleaching gel.
View Article and Find Full Text PDFThe aim of this in vitro study was to evaluate the loss of tooth structure after cavity preparation for direct (retentive) and indirect (nonretentive) restorations and its relationship to the fracture strength of the prepared tooth. Sound human third molars (60 maxillary and 60 mandibular) were randomly assigned into 12 groups (n = 10) according to the type of cavity preparation and the respective buccolingual width. Class II mesio-occlusodistal cavity preparations, for both indirect inlay and direct resin restorations, were prepared with standardized dimensions of one-half, one-third, or one-quarter of the occlusal intercuspal distance.
View Article and Find Full Text PDFConcern has been raised about the bonding of restorative procedures to an erosive lesion, given the change in organic and inorganic composition and structure of this substrate. This in vitro study evaluated the effect of erosive drinks and an enzyme inhibitor (2% chlorhexidine digluconate - 2% CHX) on bond strength to dentin. Sixty sound human third molars were selected, and the occlusal enamel was flattened, exposing the dentin surface.
View Article and Find Full Text PDFObjective: This in vitro study evaluated the effect of different bleaching protocols and the variation of pH levels of bleaching gels regarding roughness and wear of bovine enamel, after in-office bleaching protocols and brushing.
Materials And Methods: Ninety fragments were randomly divided into nine groups: C, control; WHP15, 35% hydrogen peroxide (HP) (Whiteness HP, FGM) three gel applications of 15 min each, three sessions with 1 week intervals; WHP45, 35% HP (Whiteness HP) one application/45 min, three sessions with 1 week intervals; LPS, 35% HP (Lase Peroxide, DMC) plus hybrid light (HL) [light-emitting diode (LED)/diode laser], four applications/7 min 30 sec (6 min of HL activation), one session; LPSII, 25% HP (Lase Peroxide II, DMC) plus HL, four applications/7 min 30 sec (6 min of HL activation), one session; LPL, 15% HP (Lase Peroxide Light, DMC) four applications/7 min 30 sec (6 min of HL activation), one session; WO, 35% HP (Whitegold Office, Dentsply) three applications/15 min, three sessions with 1 week intervals; WBC40, 35% HP (Whiteness HP Blue Calcium, FGM) one application/40 min, three sessions with 1 week intervals; and WBC50, 20% HP (Whiteness HP Blue Calcium) one application/50 min, three sessions with 1 week intervals. The median pH values were determined utilizing a pH meter during the initial and final gel applications.
Purpose: To evaluate the effects of toothbrushing abrasion associated with pH cycling on the surface roughness and wear of methacrylate- and silorane-based resin composites.
Methods: Microhybrid methacrylate-based (Filtek Z250), nanofilled methacrylate-based (Filtek Supreme Ultra) and microhybrid silorane-based (Filtek LS) composites were selected for this investigation. For each composite, two groups (n = 10) of rectangular specimens were made.
Objective: Tooth bleaching tends to increase enamel roughness and porosity, in addition to reducing surface microhardness. The aim of this in vitro study was to evaluate the effects of bleaching treatments using different hydrogen peroxide (HP) concentrations, with and without light activation on bovine enamel microhardness.
Materials And Methods: The buccal surfaces of sixty bovine incisors were flattened and polished and the enamel specimens were divided into six groups: G1 : c0 ontrol, exposed to artificial saliva; G2: 35% HP applied in two sessions (45' each); G3: 35% HP applied in two sessions (3 × 15' each); G4: 35% HP applied in one session (3 × 7'30") plus hybrid light (HL); G5: 25% HP applied in one session (3 × 7'30") plus HL; and G6: 15% HP applied in one session (3 × 7'30") plus HL.
Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm) were fabricated according to manufacturer instructions for each group (n = 10): Nexus 3, Kerr (NX3); RelyX ARC, 3M ESPE (ARC); RelyX U100, 3M ESPE (U100); and Variolink II, Ivoclar/Vivadent (VL2).
View Article and Find Full Text PDFLaser irradiation after the immediate application of dentin bonding systems (DBSs) and prior to their polymerization has been proposed to increase bond strength. The objective of this study was to evaluate the effect of diode laser irradiation (λ = 970 nm) on simplified DBSs through microtensile bond strength tests. Forty healthy human molars were randomly distributed among four groups (n = 10) according to DBSs used [Adper™ SingleBond 2 (SB) and Adper™ EasyOne (EO)], and the respective groups were irradiated with a diode laser (SB-L and EO-L).
View Article and Find Full Text PDFPurpose: To evaluate the effect of bleaching techniques on dentin permeability. The hypothesis was that the bleaching agent associated or not to etching and/or energy source would be able to increase dentin permeability (conductance).
Methods: Fifty 1 mm-thick disks of mid-coronal dentin were obtained from human third molars, which were mounted in a filtration chamber, allowing exposure of a standardized area of 0.
The evolution of adhesive procedures and ceramic systems has allowed for the placement of minimum thickness laminate veneers on unprepared teeth. A 20-year-old post-orthodontics male patient with multiple diastemas required restorative procedures. A multidisciplinary approach was performed, involving gingivectomy, in-office bleaching, and application of minimum thickness veneers.
View Article and Find Full Text PDF