JMIR Res Protoc
February 2024
Background: Frailty resulting from the loss of muscle quality can potentially be delayed through early detection and physical exercise interventions. There is a demand for cost-effective tools for the objective evaluation of muscle quality, in both cross-sectional and longitudinal assessments. Literature suggests that quantitative analysis of ultrasound data captures morphometric, compositional, and microstructural muscle properties, while biological assays derived from blood samples are associated with functional information.
View Article and Find Full Text PDFMedical ultrasound images are reconstructed with simplifying assumptions on wave propagation, with one of the most prominent assumptions being that the imaging medium is composed of a constant sound speed. When the assumption of a constant sound speed are violated, which is true in most in vivoor clinical imaging scenarios, distortion of the transmitted and received ultrasound wavefronts appear and degrade the image quality. This distortion is known as aberration, and the techniques used to correct for the distortion are known as aberration correction techniques.
View Article and Find Full Text PDFAdiposity accumulation in the liver is an early-stage indicator of non-alcoholic fatty liver disease. Analysis of ultrasound (US) backscatter echoes from liver parenchyma with deep learning (DL) may offer an affordable alternative for hepatic steatosis staging. The aim of this work was to compare DL classification scores for liver steatosis using different data representations constructed from raw US data.
View Article and Find Full Text PDFBackground: The purpose of this study was threefold: (I) to study the correlation of speed-of-sound (SoS) and shear-wave-speed (SWS) ultrasound (US) in the gastrocnemius muscle, (II) to use reproducible tissue compression to characterize tissue nonlinearity effects, and (III) to compare the potential of SoS and SWS for tissue composition assessment.
Methods: Twenty gastrocnemius muscles of 10 healthy young subjects (age range, 23-34 years, two females and eight males) were prospectively examined with both clinical SWS (GE Logiq E9, in m/s) and a prototype system that measures SoS (in m/s). A reflector was positioned opposite the US probe as a timing reference for SoS, with the muscle in between.
To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively examined with ultrasound. A plexiglas-reflector located on the opposite side of the probe with the calf in between was used as a timing reference for SoS (m/s).
View Article and Find Full Text PDFShort-term immobilization leads to fatty muscular degeneration, which is associated with various negative health effects. Based on literature showing very high correlations between MRI Dixon fat fraction and Speed-of-Sound (SoS), we hypothesized that we can detect short-term-immobilization-induced differences in SoS.Both calves of 10 patients with a calf cast on one side for a mean duration of 41 ± 26 days were examined in relaxed position using a standard ultrasound machine.
View Article and Find Full Text PDFWood-based composites hold the promise of sustainable construction. Understanding the influence on wood cellular microstructure in the macroscopic mechanical behavior is key for engineering high-performance composites. In this work, we report a novel Individual Cell Tracking (ICT) approach for in-situ quantification of nanometer-scale deformations of individual wood cells during mechanical loading of macroscopic millimeter-scale wood samples.
View Article and Find Full Text PDFBotulinum toxin type A (BTX-A) injections in masseter muscle can alleviate muscle tightness and aching pain caused by idiopathic masticatory myalgia, a subform of the myofascial pain syndrome. Yet the injection procedure (number, amount) is currently empirical. In this ex vivo study, we determined the feasibility of using contrast-free ultrasound imaging to visualize the short-term injectate propagation.
View Article and Find Full Text PDFObjectives: To compare speed of sound (SoS) ultrasound (US) of the calves with Dixon magnetic resonance imaging (MRI) for fat content quantification.
Materials And Methods: The study was approved by the local ethics committee. Fifty calf muscles of 35 women (age range 22-81 years) prospectively underwent an US and subsequent MRI (Dixon sequence) examination as well as body weight and impedance fat measurements.
IEEE Trans Ultrason Ferroelectr Freq Control
March 2020
Air-coupled ultrasound (ACU) is increasingly used for nondestructive testing (NDT). With ACU, no contact or coupling agent (e.g.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
December 2019
Tissue biomechanical properties are known to be sensitive to pathological changes. Accordingly, various techniques have been developed to estimate tissue mechanical properties. Shear-wave elastography (SWE) measures shear-wave speed (SWS) in tissues, which can be related to shear modulus.
View Article and Find Full Text PDFThe goal of the study was to investigate the quantitative impact of region of interest (ROI), software choice, muscle fiber orientation and preload tension on shear wave velocity (SWV). First, SWV was assessed in an isotropic elasticity phantom and ex vivo porcine muscle using a commercially available clinical ultrasound system. Secondly, SWV was acquired in relaxed and stretched calf muscles of healthy volunteers (dorsal extension of the talocrural joint), for both parallel and transverse probe direction to the fibers, as well as for different ROIs and software versions.
View Article and Find Full Text PDFTo investigate changes in breast density (BD) during the menstrual cycle in young women in comparison to inter-breast and -segment changes as well as reproducibility of a novel Speed-of-Sound (SoS) Ultrasound (US) method.SoS-US uses a conventional US system with a reflector and a software add-on to quantify SoS in the retro-mammillary, inner and outer segments of both breasts. Twenty healthy women (18-40 years) with regular menstrual cycles were scanned twice with two weeks in-between.
View Article and Find Full Text PDFPurpose: The aim of this study was to differentiate malignant and benign solid breast lesions with a novel ultrasound (US) technique, which measures speed of sound (SoS) using standard US transducers and intrinsic tissue reflections and scattering (speckles) as internal reference.
Materials And Methods: This prospective, institutional review board-approved, Health Insurance Portability and Accountability Act-compliant prospective comparison study was performed with prior written informed consent from 20 women. Ten women with histological proven breast cancer and 10 with fibroadenoma were measured.
Medical ultrasonic arrays are typically characterized in controlled water baths using measurements by a hydrophone, which can be translated with a positioning stage. Characterization of 3D acoustic fields conventionally requires measurements at each spatial location, which is tedious and time-consuming, and may be prohibitive given limitations of experimental setup (e.g.
View Article and Find Full Text PDFObjective: Speed-of-sound (SoS) has large potential for tissue and pathology differentiation. We aim to develop a novel Ultrasound Computed Tomography (USCT) technique that can reconstruct local SoS in tissue on conventional ultrasound machines with hand-held linear arrays.
Methods: A passive reflector is placed opposite the tissue sample as an echogenic reference to measure the time-of-flight (ToF) of ultrasound wave- fronts.
Despite many uses of ultrasound, some pathologies such as breast cancer still cannot reliably be diagnosed in either conventional B-mode ultrasound imaging nor with more recent ultrasound elastography methods. Speed-of-sound (SoS) is a quantitative imaging biomarker, which is sensitive to structural changes due to pathology, and hence could facilitate diagnosis. Full-angle ultrasound computed tomography (USCT) was proposed to obtain spatially-resolved SoS images, however, its water-bath setup involves practical limitations.
View Article and Find Full Text PDFObjectives: To measure speed of sound (SoS) with a novel hand-held ultrasound technique as a quantitative indicator for muscle loss and fatty muscular degeneration.
Methods: Both calf muscles of 11 healthy, young females (mean age 29 years), and 10 elderly females (mean age 82 years) were prospectively examined with a standard ultrasound machine. A flat Plexiglas® reflector, on the opposite side of the probe with the calf in between, was used as timing reference for SoS (m/s) and ΔSoS (variation of SoS, m/s).
IEEE Trans Med Imaging
November 2018
Biomedical parameters of tissue can be important indicators for clinical diagnosis. One such parameter that reflects tissue stiffness is elasticity, the imaging of which is called elastography. In this paper, we use displacements from harmonic excitations to solve the inverse problem of elasticity based on a finite-element method (FEM) formulation.
View Article and Find Full Text PDFObjectives: To assess feasibility and diagnostic accuracy of a novel hand-held ultrasound (US) method for breast density assessment that measures the speed of sound (SoS), in comparison to the ACR mammographic (MG) categories.
Methods: ACR-MG density (a=fatty to d=extremely dense) and SoS-US were assessed in the retromamillary, inner and outer segments of 106 women by two radiographers. A conventional US system was used for SoS-US.
IEEE Trans Ultrason Ferroelectr Freq Control
January 2018
Quantitative and reproducible air-coupled ultrasound (ACU) testing requires characterization of the volumetric pressure fields radiated by ACU probes. In this paper, a closed-form reradiation method combining the Rayleigh-Sommerfeld integral and time-reversal acoustics is proposed, which allows calculation of both near- field and far-field based on a single-plane measurement. The method was validated for both 3-D (circular, square) and 2-D (rectangular) planar transducers in the 50-230 kHz range.
View Article and Find Full Text PDFPurpose: To evaluate needle visibility in ultrasound under contrast mode conditions.
Materials And Methods: Needle visibility was evaluated for bevel, EchoTip and shaft of 18G Chiba biopsy needle with a 9 MHz linear probe (GE Logiq E9). Insertion angles varied between 30°(steep) and 90°(parallel to the probe surface).
Reliable non-destructive testing (NDT) ultrasound systems for timber composite structures require quantitative understanding of the propagation of ultrasound beams in wood. A finite-difference time-domain (FDTD) model is described, which incorporates local anisotropy variations of stiffness, damping and density in timber elements. The propagation of pulsed air-coupled ultrasound (ACU) beams in normal and slanted incidence configurations is reproduced by direct definition of material properties (gas, solid) at each model pixel.
View Article and Find Full Text PDFInt J Comput Assist Radiol Surg
June 2015
Purpose: We demonstrate a novel method for automatic direct lesion depth (LD) tracking during coagulation from time series of a single A-mode ultrasound (US) transducer custom fit at the tip of a RFA catheter. This method is named thermal expansion imaging (TEI).
Methods: A total of 35 porcine myocardium samples were ablated (LD 0.
Non-destructive assessment of delaminations in glued laminated timber structures is required during their full life cycle. A novel air-coupled ultrasound (ACU) method has been developed, which is able to separately detect delaminations in individual bonding planes of arbitrarily high and long laminated stacks and typically 200 mm wide. The 120 kHz ACU transmitter-receiver pair is positioned at two opposite lateral faces of the sample, with a small inclination with respect to the inspected bonding planes, so that an ultrasound beam is excited at a user-defined refraction angle within the sample, interacting with defects in a limited height portion of the stack.
View Article and Find Full Text PDF