Publications by authors named "Sergio Di Molfetta"

Despite the growing evidence supporting the outpatient use of continuous glucose monitoring (CGM) for improving glycaemic control and reducing hypoglycaemia, there is a need for a detailed understanding of the specific features of CGM devices that best meet individual patient needs. This expert opinion, based on a comprehensive literature review and the personal perspectives of clinicians, aims to provide the healthcare professionals (HCPs) with a comprehensive framework for selecting CGM devices. It evaluates the current state of CGM technology, categorizing features into essential features, major drivers of choice, and additional/useful features.

View Article and Find Full Text PDF

Aims: To compare the efficacy and safety of different hybrid closed loop (HCL) systems in people with diabetes through a network meta-analysis.

Methods: We searched MEDLINE, EMBASE, CENTRAL and PubMed for randomised clinical trials (RCTs) enrolling children, adolescents and/or adults with type 1 or type 2 diabetes, evaluating Minimed 670G, Minimed 780G, Control-IQ, CamAPS Fx, DBLG-1, DBLHU, and Omnipod 5 HCL systems against other types of insulin therapy, and reporting time in target range (TIR) as outcome.

Results: A total of 28 RCTs, all enrolling people with type 1 diabetes, were included.

View Article and Find Full Text PDF

Background And Aims: Insulin resistance is a growing feature in type 1 diabetes (T1D). It can be quantified by calculating the estimated glucose disposal rate (eGDR) with the Epstein's formula, which includes laboratory-measured glycated hemoglobin (HbA1c). We aimed the current research to assess the agreement between the conventional eGDR formula and an alternative one (eGDR-GMI) incorporating the glucose management indicator (GMI) derived from continuous glucose monitoring (CGM).

View Article and Find Full Text PDF

Neuroendocrine neoplasms (NENs), arising from various sites, present therapeutic challenges. Radioligand therapy (RLT) is effective for unresectable/metastatic NENs with increased somatostatin receptor uptake. While evidence supports RLT's efficacy in midgut NETs, its role in lung NETs remains underexplored.

View Article and Find Full Text PDF

Pancreatic neuroendocrine neoplasms (Pan-NENs) may exhibit a heterogeneous clinical course, ranging from indolent to progressive/metastatic behavior. In the latter scenario, streptozocin (STZ) is considered the cornerstone of systemic treatment; however, response to STZ-based chemotherapy may vary among individuals. In this narrative review, we aimed to identify the predictive factors of response to STZ in advanced Pan-NENs.

View Article and Find Full Text PDF

Background: Innovative GLP-1 receptor agonist (GLP-1RA)-based treatment strategies-such as tirzepatide, GLP-1RA plus basal insulin fixed-ratio combinations [FRC], GLP-1RA plus sodium glucose cotransporter-2 inhibitors [SGLT-2i] combinations, and high-dose GLP-1RA-have been listed among the most efficacious options for type 2 diabetes management. However, differences in their glucometabolic effects have not been assessed in dedicated head-to-head trials. In the absence of such trials, we aimed to provide a useful comparison among these treatment strategies to guide clinical practice.

View Article and Find Full Text PDF

Aims: To investigate the benefits of using the Personalized Treatment Tool (PTT), a web-based clinical decision support tool assisting the diabetologist in the evaluation of patient's clinical characteristics and SMBG data, in the management of patients with non-insulin treated type 2 diabetes and inadequate glucose control.

Methods: We conducted a single-center, 16-week, cluster-randomized controlled trial.

Results: Eighty-two patients with 64.

View Article and Find Full Text PDF

Optical coherence tomography angiography (OCTA) is an innovative and reliable technique detecting the early preclinical retinal vascular change in patients with diabetes. We have designed our study to evaluate whether an independent relationship exists between continuous glucose monitoring (CGM)-derived glucose metrics and OCTA parameters in young adult patients with type 1 diabetes without diabetic retinopathy (DR). Inclusion criteria were age ≥ 18 years, diagnosis of type 1 diabetes from ≥ 1 year, stable insulin treatment in the last three months, use of real-time CGM, and CGM wear time ≥ 70%.

View Article and Find Full Text PDF

Background: Continuous glucose monitoring (CGM) users are encouraged to consider trend arrows before injecting a meal bolus. We evaluated the efficacy and safety of two different algorithms for trend-informed bolus adjustments, the Diabetes Research in Children Network/Juvenile Diabetes Research Foundation (DirectNet/JDRF) and the Ziegler algorithm, in type 1 diabetes.

Methods: We conducted a cross-over study of type 1 diabetes patients using Dexcom G6.

View Article and Find Full Text PDF

Aim: To evaluate the effect on glucose control of professional continuous glucose monitoring (p-CGM)-based care as compared with standard care in the management of patients with type 1 and type 2 diabetes.

Materials And Methods: The PubMed database was searched comprehensively to identify prospective or retrospective studies evaluating p-CGM as a diagnostic tool for subsequent implementation of lifestyle and/or medication changes and reporting glycated haemoglobin (HbA1c) as an outcome measure.

Results: We found 872 articles, 22 of which were included in the meta-analysis.

View Article and Find Full Text PDF

Peptide receptor radionuclide therapy (PRRT), also called radioligand therapy, is an effective antitumoral treatment in patients with neuroendocrine neoplasm (NEN). It improves the patient's health-related quality of life (HRQoL), which is evaluated by self-assessment questionnaires. The aim of this narrative review was to report the current knowledge on the changes of HRQoL and sexual function in patients with NEN treated with PRRT.

View Article and Find Full Text PDF

Despite multiple pharmacological options, including rapid-acting insulin analogs, postprandial hyperglycemia is still highly prevalent in patients with type 1 and type 2 diabetes. We hypothesize that the new rapid-acting insulin formulation, the so-called faster-acting Aspart, may have a different effect in controlling postprandial hyperglycemic burden according to the quality of the meal compared to the traditional Aspart. Twenty-five patients with type 1 diabetes were consecutively recruited at the diabetes care center of the University Hospital affiliate of the Magna Græcia University of Catanzaro.

View Article and Find Full Text PDF

Background And Aim: The use of technology offers recognized benefits to persons with diabetes. The aim of this study was to evaluate the organization of healthcare facilities, the composition of the diabetes team, and the use of Continuous Subcutaneous Insulin Infusion (CSII) and Continuous Glucose Monitoring (CGM) in Italy.

Methods And Results: Diabetes care centers were asked to complete a web survey based on information collected in 2018.

View Article and Find Full Text PDF

Wider access to continuous glucose monitoring systems, including flash glucose monitoring, has enabled people with diabetes to achieve lower HbA1c levels and reduce the amount of time they spend in hypoglycaemia or hyperglycaemia, and has improved their quality of life. An International Consensus Panel proposed different target glucose ranges and recommendations according to different ages and situations (adults, young people and children with type 1 or type 2 diabetes, as well as elderly people who are at higher risk of hypoglycaemia, and women with diabetes during pregnancy). In this expert opinion, we interpret the international recommendations in the context of established clinical practice for diabetes care, and propose three different step-by-step algorithms to help the healthcare professionals use the most innovative glucose metrics, including time in glucose ranges, glucose management indicator, coefficient of variation, and ambulatory glucose profile.

View Article and Find Full Text PDF

Background: Overall survival after lymphoma has improved in recent years, but the high prevalence of late treatment-related sequelae has been observed as a counterpart.

Method: In this systematic review, FIL researchers aimed to: (i) estimate the incidence or prevalence of late endocrine-metabolic sequelae, (ii) evaluate the effects of modern therapeutic approaches on incidence or prevalence of late endocrine-metabolic sequelae, and (iii) determine whether there is evidence of follow-up schemes for their screening/early diagnosis in the subset of long-term classical Hodgkin lymphoma (cHL) and diffuse large B-cell lymphoma (DLBCL) survivors treated at adult age. The MEDLINE, Embase and the Cochrane Library databases were searched for relevant articles published up to October, 2020.

View Article and Find Full Text PDF

Lung carcinoids are well-differentiated and low-/intermediate-grade neuroendocrine neoplasms of the lung. Given their relative rarity, and the paucity of data available from prospective studies, no global consensus exists on the systemic treatment of these tumours. In recent years, immune checkpoint inhibitors have revolutionized cancer management and are under evaluation in patients with diverse types of neuroendocrine neoplasms.

View Article and Find Full Text PDF

Aims: To investigate the relationship between single therapeutic interventions and indicatorsofglycemic control in the PRISMA trial, a large study comparing the effects of intensive structured SMBG (ISM) vs. active control (AC) in non-insulin-treated type 2 diabetes (T2D).

Methods: Information was collected at four time points, corresponding to months 3, 6, 9, and 12 and visits 2, 3, 4, and 5, respectively.

View Article and Find Full Text PDF

Medullary thyroid carcinoma is a rare neuroendocrine neoplasm that originates from thyroid C cells. Surgery, with complete resection of the tumor, is the only curative approach. However, in most cases, the tumor recurs at locoregional or metastatic level.

View Article and Find Full Text PDF

Pheochromocytoma and paraganglioma are neuroendocrine neoplasms, originating in the adrenal medulla and in parasympathetic and sympathetic autonomic nervous system ganglia, respectively. They usually present as localized tumours curable with surgery. However, these tumours may exhibit heterogeneous clinical course, ranging from no/minimal progression to aggressive (progressive/metastatic) behavior.

View Article and Find Full Text PDF

Gut microbiota is represented by different microorganisms that colonize the intestinal tract, mostly the large intestine, such as bacteria, fungi, archaea and viruses. The gut microbial balance has a key role in several functions. It modulates the host's metabolism, maintains the gut barrier integrity, participates in the xenobiotics and drug metabolism, and acts as protection against gastro-intestinal pathogens through the host's immune system modulation.

View Article and Find Full Text PDF

Aims: To assess changes in glucose metrics and their association with psychological distress and lifestyle changes in patients with type 1 diabetes (T1D) using flash glucose monitoring (FGM) during lockdown following severe acute respiratory syndrome coronavirus 2 outbreak.

Materials And Methods: Single-centre, observational, retrospective study enrolling T1D patients who attended a remote visit on April 2020 at the Endocrinology division of the University Hospital Policlinico Consorziale, Bari, Italy. Lockdown-related changes in physical activity level and dietary habits were assessed on a semi-quantitative basis.

View Article and Find Full Text PDF
Article Synopsis
  • Flash glucose monitoring (FGM) is a sensor-based technology that measures glucose levels in patients with type 1 and type 2 diabetes, and a systematic review assessed its efficacy and safety in over 2100 patients.
  • The review found FGM use led to a significant reduction in HbA1c levels and decreased time spent below 70 mg/dL, with positive patient-reported outcomes and no serious adverse events related to the device.
  • When compared to traditional self-monitoring blood glucose (SMBG), FGM required fewer daily SMBG measurements and had a lower discontinuation risk, although the studies reviewed had varying designs and limited follow-up.
View Article and Find Full Text PDF

Aims: This real-world study evaluated the changes in glycated haemoglobin (HbA1c) and continuous glucose monitoring (CGM) metrics associated with use of the implantable 180-day Eversense CGM System (Eversense) in patients with type 1 diabetes.

Materials And Methods: This was a prospective, multicentre, observational study among adult participants aged ≥18 years with type 1 diabetes across seven diabetes-care centres in Italy who had Eversense inserted for the first time. HbA1c was measured at baseline and at 180 days.

View Article and Find Full Text PDF