Publications by authors named "Sergey S Poteshin"

In Hadamard transform ion mobility spectrometry (HT IMS), the signal-to-noise ratio is always lower for non-modified pseudorandom sequences than for modified sequences. Since the use of non-modified modulating pseudorandom sequences is strategically preferable from a duty cycle standpoint, we investigated the change in the interference signal when transitioning from non-modified modulating sequences to sequences modified by the addition of 1,3,5 and 7 zeros. The interfering signal in HT IMS with modified pseudorandom sequences was shown to be mainly random noise for all the cases except for modifying by incorporation of 1 zero.

View Article and Find Full Text PDF

We describe an original multisectional quadrupole ion trap aimed to realize nuclear frequency standard based on the unique isomer transition in thorium nucleus. It is shown that the system effectively operates on Th, Th and Th ions produced by laser ablation of metallic thorium-232 target. Laser intensity used for ablation is about 6 GW/cm.

View Article and Find Full Text PDF

We consider an experiment on trapping and laser cooling of Th ions in a linear Paul trap in the presence of undesirable impurities such as ions of the radioactive isotope Th. We suggest a method of separating these impurities by means of selective laser cooling utilizing the isotope shift of cooling transitions in Th and Th ions. According to our estimation, the isotope shift is equal to 3.

View Article and Find Full Text PDF

An ion mobility time-of-flight mass spectrometry (IM-TOFMS)-based method has been preliminarily investigated for the identification of triphenylmethane ballpoint pen dyes on paper. The dyes were sampled from one-year-old ballpoint pen ink entries. The entries were written on paper documents stored in the dark in a bookcase.

View Article and Find Full Text PDF

The Russian Emission Detector 100 (RED-100) under construction at the National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) is designed to detect the presently undiscovered effect of coherent neutrino scattering. One of the factors limiting the sensitivity of the detector is the spontaneous decay of uranium and thorium in the detector materials. Radioactive impurities in detector materials at levels of parts per billion can significantly affect the sensitivity.

View Article and Find Full Text PDF

There is a growing need for the development of atomic and nuclear frequency standards because of the important contribution of methods for precision time and frequency measurements to the development of fundamental science, technology, and the economy. It is also conditioned by their potential use in optical clocks and quantum logic applications. It is especially important to develop a universal method that could allow one to use ions of most elements effectively (including ones that are not easily evaporated) proposed for the above-mentioned applications.

View Article and Find Full Text PDF

Characteristic ion mobility mass spectrometry data, reduced mobility, and limits of detection (signal-to-noise ratio = 3) were determined for six synthetic drugs and cocaine by ion mobility time-of-flight mass spectrometry (IM-TOF-MS) with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI). The studied synthetic illicit drugs recently appeared on the recreational drug market as designer drugs and were methylone, 4-MEC (4'-methylethcathinone), 3,4-MDPV (3,4-methylenedioxypyrovalerone), JWH-210 [4-ethylnaphthalen-1-yl-(1-pentylindol-3-yl)methanone], JWH-250 [2-(2-methoxyphenyl)-1-(1-pentyl-1H-indol-3-yl)ethanone], and JWH-203 [1-pentyl-3-(2'-chlorophenylacetyl) indole]. Absolute reduced mobilities in nitrogen were 1.

View Article and Find Full Text PDF

Recently developed ion mobility mass spectrometer is described. The instrument is based on a drift tube ion mobility spectrometer and an orthogonal acceleration electrostatic sector time-of-flight mass analyzer. Data collection is performed using a specially developed fast ADC-based recorder that allows real-time data integration in an interval between 3 and 100 s.

View Article and Find Full Text PDF