Publications by authors named "Sergey Makaroff"

Background: Modeling brain stimulation at the microscopic scale may reveal new paradigms for various stimulation modalities.

Objective: We present the largest map to date of extracellular electric field distributions within a layer L2/L3 mouse primary visual cortex brain sample. This was enabled by the automated analysis of serial section electron microscopy images with improved handling of image defects, covering a volume of 250 × 140 × 90 μm³.

View Article and Find Full Text PDF

Electroencephalographic (EEG) source localization is a fundamental tool for clinical diagnoses and brain-computer interfaces. We investigate the impact of model complexity on reconstruction accuracy by comparing the widely used three-layer boundary element method (BEM) as an inverse method against a five-layer BEM accelerated by the fast multipole method (BEM-FMM) and coupled with adaptive mesh refinement (AMR) as forward solver. Modern BEM-FMM with AMR can solve high-resolution multi-tissue models efficiently and accurately.

View Article and Find Full Text PDF

Notwithstanding advances in computational models of neuromodulation, there are mismatches between simulated and experimental activation thresholds. Transcranial Magnetic Stimulation (TMS) of the primary motor cortex generates motor evoked potentials (MEPs). At the threshold of MEP generation, whole-head models predict macroscopic (at millimeter scale) electric fields (50-70 V/m) which are considerably below conventionally simulated cortical neuron thresholds (200-300 V/m).

View Article and Find Full Text PDF

Background: Although transcranial magnetic stimulation (TMS) has become a valuable method for non-invasive brain stimulation, the cellular basis of TMS activation of neurons is still not fully understood. In vitro preparations have been used to understand the biophysical mechanisms of TMS, but in many cases these studies have encountered substantial difficulties in activating neurons.

Objective/hypothesis: The hypothesis of this work is that conductivity boundaries can have large effects on the electric field in commonly used in vitro preparations.

View Article and Find Full Text PDF

A BEM (boundary element method) based approach is developed to accurately solve an EEG/MEG forward problem for a modern high-resolution head model in approximately 60 seconds using a common workstation. The method utilizes a charge-based BEM with fast multipole acceleration (BEM-FMM) and a "smart" mesh pre-refinement (called -refinement) close to the singular source(s). No costly matrix-filling or direct solution steps typical for the standard BEM are required; the method generates on-skin voltages as well as MEG magnetic fields for high-resolution head models in approximately 60 seconds after initial model assembly.

View Article and Find Full Text PDF

Objective: To compare cortical dipole fitting spatial accuracy between the widely used yet highly simplified 3-layer and modern more realistic 5-layer BEM-FMM models with and without (AMR) methods.

Methods: We generate simulated noiseless 256-channel EEG data from 5-layer (7-compartment) meshes of 15 subjects from the Connectome Young Adult dataset. For each subject, we test four dipole positions, three sets of conductivity values, and two types of head segmentation.

View Article and Find Full Text PDF

Unlabelled: Modeling brain stimulation at the microscopic scale may reveal new paradigms for various stimulation modalities. We present the largest map to date of extracellular electric field distributions within a layer L2/L3 mouse primary visual cortex brain sample. This was enabled by the automated analysis of serial section electron microscopy images with improved handling of image defects, covering a volume of 250 × 140 × 90 μm .

View Article and Find Full Text PDF

Neurostimulation devices that use rotating permanent magnets are being explored for their potential therapeutic benefits in patients with psychiatric and neurological disorders. This study aims to characterize the electric field (E-field) for ten configurations of rotating magnets using finite element analysis and phantom measurements. Various configurations were modeled, including single or multiple magnets, and bipolar or multipolar magnets, rotated at 10, 13.

View Article and Find Full Text PDF

Neurostimulation devices that use rotating permanent magnets are being explored for their potential therapeutic benefits in patients with psychiatric and neurological disorders. This study aims to characterize the electric field (E-field) for ten configurations of rotating magnets using finite element analysis and phantom measurements. Various configurations were modeled, including single or multiple magnets, bipolar or multipolar magnets, rotated at 10, 13.

View Article and Find Full Text PDF

In our recent work pertinent to modeling of brain stimulation and neurophysiological recordings, substantial modeling errors in the computed electric field and potential have sometimes been observed for standard multi-compartment head models. The goal of this study is to quantify those errors and, further, eliminate them through an adaptive mesh refinement (AMR) algorithm. The study concentrates on transcranial magnetic stimulation (TMS), transcranial electrical stimulation (TES), and electroencephalography (EEG) forward problems.

View Article and Find Full Text PDF

One limitation on the ability to monitor health in older adults using magnetic resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: (1) an in silico human model based on the widely available Visible Human Project (VHP) cryo-section dataset; (2) a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The in silico VHP-Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index of 36.

View Article and Find Full Text PDF

Transcranial magnetic stimulation (TMS) studies with small animals can provide useful knowledge of activating regions and mechanisms. Along with this, functional magnetic resonance imaging (fMRI) in mice and rats is increasingly often used to draw important conclusions about brain connectivity and functionality. For cases of both low- and high-frequency TMS studies, a high-quality computational surface-based rodent model may be useful as a tool for performing supporting modeling and optimization tasks.

View Article and Find Full Text PDF

. Transcranial magnetic stimulation (TMS) coil design involves a tradeoff among multiple parameters, including magnetic flux density (), inductance (), induced electric () field, focality, penetration depth, coil heating, etc. Magnetic materials with high permeability have been suggested to enhance coil efficiency.

View Article and Find Full Text PDF

An on-body antenna, comprised of two closely-spaced antiphase patch elements, for microwave imaging may provide enhanced signal penetration into the tissue. By further integrating a 180-degree on-chip power combiner with the dual antiphase patch antenna element, a low-profile miniaturized antenna, integrated into a single 18.5 mm x 10 mm x 1.

View Article and Find Full Text PDF

On-body antennas for use in microwave imaging (MI) systems can direct energy around the body instead of through the body, thus degrading the overall signal-to-noise ratio (SNR) of the system. This work introduces and quantifies the usage of modern metal-backed RF absorbing foam in conjunction with on-body antennas to dampen energy flowing around the body, using both simulations and experiments. A head imaging system is demonstrated herein but the principle can be applied to any part of the body including the torso or extremities.

View Article and Find Full Text PDF

Objective: This study aims to describe a MATLAB software package for transcranial magnetic stimulation (TMS) coil analysis and design.

Approach: Electric and magnetic fields of the coils as well as their self- and mutual (for coil arrays) inductances are computed, with or without a magnetic core. Solid and stranded (Litz wire) conductors are also taken into consideration.

View Article and Find Full Text PDF

One limitation on the ability to monitor health in older adults using Magnetic Resonance (MR) imaging is the presence of implants, where the prevalence of implantable devices (orthopedic, cardiac, neuromodulation) increases in the population, as does the pervasiveness of conditions requiring MRI studies for diagnosis (musculoskeletal diseases, infections, or cancer). The present study describes a novel multiphysics implant modeling testbed using the following approaches with two examples: - an human model based on the widely available Visible Human Project (VHP) cryo-section dataset; - a finite element method (FEM) modeling software workbench from Ansys (Electronics Desktop/Mechanical) to model MR radio frequency (RF) coils and the temperature rise modeling in heterogeneous media. The VHP Female model (250 parts with an additional 40 components specifically characterizing embedded implants and resultant surrounding tissues) corresponds to a 60-year-old female with a body mass index (BMI) of 36.

View Article and Find Full Text PDF

Objective: In our recent work pertinent to modeling of brain stimulation and neurophysiological recordings, substantial modeling errors in the computed electric field and potential have sometimes been observed for standard multi-compartment head models. The goal of this study is to quantify those errors and, further, eliminate them through an adaptive mesh refinement (AMR) algorithm. The study concentrates on transcranial magnetic stimulation (TMS), transcranial electrical stimulation (TES), and electroencephalography (EEG) forward problems.

View Article and Find Full Text PDF

Objective: Biophysical models of neural stimulation are a valuable approach to explaining the mechanisms of neuronal recruitment via applied extracellular electric fields. Typically, the applied electric field is estimated via a macroscopic finite element method solution and then applied to cable models as an extracellular voltage source. However, the field resolution is limited by the finite element size (typically 10's-100's of times greater than average neuronal cross-section).

View Article and Find Full Text PDF

The motor hyperdirect pathway (HDP) is a key target in the treatment of Parkinson's disease with deep brain stimulation (DBS). Biophysical models of HDP DBS have been used to explore the mechanisms of stimulation. Built upon finite element method volume conductor solutions, such models are limited by a resolution mismatch, where the volume conductor is modeled at the macro scale, while the neural elements are at the micro scale.

View Article and Find Full Text PDF

Accurate modeling of transcranial magnetic stimulation (TMS) coils with the magnetic core is largely an open problem since commercial (quasi) magnetostatic solvers do not output specific field characteristics (e.g. induced electric field) and have difficulties when incorporating realistic head models.

View Article and Find Full Text PDF