Purpose: The recently proposed Integrated Physical Optimization Intensity Modulated Proton Therapy (IPO-IMPT) framework allows simultaneous optimization of dose, dose rate, and linear energy transfer (LET) for ultra-high dose rate (FLASH) treatment planning. Finding solutions to IPO-IMPT is difficult because of computational intensiveness. Nevertheless, an inverse solution that simultaneously specifies the geometry of a sparse filter and weights of a proton intensity map is desirable for both clinical and preclinical applications.
View Article and Find Full Text PDFThis work of fiction is part of a case study series developed by the Medical Physics Leadership Academy (MPLA). It is intended to facilitate the discussion of how students and advisors can better communicate expectations and navigate difficult conversations. In this case, a fourth-year Ph.
View Article and Find Full Text PDF. The aim of this study was to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH proton radiotherapy using a pixelated semiconductor detector..
View Article and Find Full Text PDFShoot-through proton FLASH radiation therapy has been proposed where the highest energy is extracted from a cyclotron to maximize the dose rate (DR). Although our proton pencil beam scanning system can deliver 250 MeV (the highest energy), this energy is not used clinically, and as such, 250 MeV has yet to be characterized during clinical commissioning. We aim to characterize the 250-MeV proton beam from the Varian ProBeam system for FLASH and assess the usability of the clinical monitoring ionization chamber (MIC) for FLASH use.
View Article and Find Full Text PDFPurpose: Patient-specific ridge filters provide a passive means to modulate proton energy to obtain a conformal dose. Here we describe a new framework for optimization of filter design and spot maps to meet the unique demands of ultrahigh-dose-rate (FLASH) radiation therapy. We demonstrate an integrated physical optimization Intensity-modulated proton therapy (IMPT) (IPO-IMPT) approach for optimization of dose, dose-averaged dose rate (DADR), and dose-averaged linear energy transfer (LET).
View Article and Find Full Text PDFPurpose: Metallic implants have been correlated to local control failure for spinal sarcoma and chordoma patients due to the uncertainty of implant delineation from computed tomography (CT). Such uncertainty can compromise the proton Monte Carlo dose calculation (MCDC) accuracy. A component method is proposed to determine the dimension and volume of the implants from CT images.
View Article and Find Full Text PDFJ Appl Clin Med Phys
October 2022
FLASH radiotherapy (RT) is a novel technique in which the ultrahigh dose rate (UHDR) (≥40 Gy/s) is delivered to the entire treatment volume. Recent outcomes of in vivo studies show that the UHDR RT has the potential to spare normal tissue without sacrificing tumor control. There is a growing interest in the application of FLASH RT, and the ultrahigh dose irradiation delivery has been achieved by a few experimental and modified linear accelerators.
View Article and Find Full Text PDFObjective: Dual energy CT (DECT) has been shown to estimate stopping power ratio (SPR) map with a higher accuracy than conventional single energy CT (SECT) by obtaining the energy dependence of photon interactions. This work presents a learning-based method to synthesize DECT images from SECT image for proton radiotherapy.
Methods: The proposed method uses a residual attention generative adversarial network.
Purpose; For shoot-through proton treatments, like FLASH radiotherapy, there will be protons exiting the patient which can be used for proton portal imaging (PPI), revealing valuable information for the validation of tumor location in the beam's-eye-view at native gantry angles. However, PPI has poor inherent contrast and spatial resolution. To deal with this issue, we propose a deep-learning-based method to use kV digitally reconstructed radiographs (DRR) to improve PPI image quality.
View Article and Find Full Text PDFThe presence of artificial implants complicates the delivery of proton therapy due to inaccurate characterization of both the implant and the surrounding tissues. In this work, we describe a method to characterize implant and human tissue mimicking materials in terms of relative stopping power (RSP) using a novel proton counting detector. Each proton is tracked by directly measuring the deposited energy along the proton track using a fast, pixelated spectral detector AdvaPIX-TPX3 (TPX3).
View Article and Find Full Text PDFPurpose: In this study, we investigated computationally and experimentally a hexagonal-pattern array of spatially fractionated proton minibeams produced by proton pencil beam scanning (PBS) technique. Spatial fractionation of dose delivery with millimeter or submillimeter beam size has proven to be a promising approach to significantly increase the normal tissue tolerance. Our goals are to obtain an optimized minibeam design and to show that it is feasible to implement the optimized minibeams at the existing proton clinics.
View Article and Find Full Text PDFNew technique is trending in spatially fractionated radiotherapy with protons to utilize the spot scanning together with a physical collimator to obtain minibeams. The primary goal of this study is to quantify ambient neutron dose equivalent (${H}^{\ast }(10)$) due to the secondary neutrons when physical collimator is used to achieve desired minibeams. The ${H}^{\ast }(10)$ per treatment proton dose (D) was assessed using Monte Carlo code TOPAS and measured using WENDI-II detector at different angles (135, 180, 225 and 270 degrees) and distances (11 cm, 58 and 105 cm) from the phantom for two cases: with and without physical collimation.
View Article and Find Full Text PDF