Environ Sci Process Impacts
December 2015
The Canadian population is currently subject to low, chronic lead exposure and an understanding of its effects is of great significance to the population's health. Such low exposure is difficult to measure directly; approximation by physiologically based modeling may provide a preferable approach to population analysis. The O'Flaherty model of lead kinetics is based on an age-dependent approach to human growth and development and devotes special attention to bone turnover rates.
View Article and Find Full Text PDFA (109)Cd K X-ray fluorescence (KXRF) measurement system consisting of four detectors in clover-leaf geometry is a non-invasive, low-radiation-dose method of measuring bone lead concentration. Its high precision in estimating the bone lead content makes it a promising tool for the determination of the low levels of lead currently found in the general population. After developing the clover-leaf geometry system, the system was used for the first time in a major survey in 2008 to measure the lead levels of 497 smelter employees (an occupationally exposed group with high lead levels).
View Article and Find Full Text PDFEnviron Sci Process Impacts
July 2014
The overwhelming proportion of the mass of lead (Pb) is stored in bone and the residence time of Pb in bone is much longer than that in other tissues. Hence, in a metabolic model that we used to solve the differential equations governing the transfer of lead between body compartments, three main compartments are involved: blood (as a transfer compartment), cortical bone (tibia), and trabecular bone (calcaneus). There is a bidirectional connection between blood and the other two compartments.
View Article and Find Full Text PDF494 smelter employees from New Brunswick participated in a bone lead survey conducted by McMaster University in 2008, using the four element "clover-leaf" geometry germanium detector system. The employees were measured at two different bone sites, tibia and calcaneus, each measurement lasting 30 minutes. Scattered photons, including Pb X-rays, were collected by the germanium detectors located behind the ¹⁰⁹Cd source.
View Article and Find Full Text PDFA total of 497 smelter employees from New Brunswick participated in a bone lead survey conducted by McMaster University in 2008 to examine the efficiency of lead exposure control programmes and a four-element 'clover-leaf' geometry detector system. Nearly 42% of the subjects had participated in both the previous surveys performed in 1994 and 1999. After developing the clover-leaf geometry system in 2006, the reliability of the system based on examining the consistency of four detectors and improving the minimum detection limit (MDL) was tested for the first time in 2008 by measuring lead levels of a large population that was occupationally exposed to lead.
View Article and Find Full Text PDF