Background/purpose: Selecting an appropriate coronal restoration after root canal treatment requires careful consideration, however, there is a lack of established web-based tool that is based on clear guidelines for suitable post-endodontic restorations. Hence, we aimed to design and determine the acceptability of an interactive application to aid the decision making process for post-endodontic restoration among the undergraduate dental students.
Materials And Methods: A web-based post-endodontic restoration decision making interactive application, ( was developed after a detailed review of available literature.
Aims And Objectives: To analyze anti-MMP mode of action of Quaternary Ammonium Silane (QAS, codenamed as k21) by binding onto specific MMP site using computational molecular simulation and Anti-Sortase A (SrtA) mode of action by binding onto specific site using computational molecular simulation.
Materials And Methods: In silico Molecular Dynamics (MD) was used to determine the interactions of K21 inside the pocket of the targeted protein (crystal structure of fibroblast collagenase-1 complexed to a diphenyl-ether sulphone based hydroxamic acid; PDB ID: 966C; Crystal structure of MMP-2 active site mutant in complex with APP-derived decapeptide inhibitor. MD simulations were accomplished with the Desmond package in Schrödinger Drug Discovery Suite.
Statement Of Problem: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking.
Purpose: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions.
Objectives: Successful root canal therapy is dependent on the efficacy of complete instrumentation and adequate use of chemical irrigant to eliminate the biofilm from dentin surface. The aim of the study was to examine antibiofilm and antimicrobial effectiveness of newly formulated Quaternary ammonium silane (QAS/also codenamed K21; against and biofilm on radicular dentin with evaluation of the anti-inflammatory consequence .
Methods: Fourier Transform Infrared Spectroscopy (FTIR) was performed after complete hydrolysis of K21 solution.
Background: The ability of cancer cells to be invasive and metastasize depend on several factors, of which the action of protease activity takes center stage in disease progression.
Purpose/objective: To analyze function of new K21 molecule in the invasive process of oral squamous cell carcinoma (OSCC) cell line.
Materials & Methods: The Fusobacterium (ATCC 23726) streaks were made, and pellets were resuspended in Cal27 (ATCC CRL-2095) OSCC cell line spheroid cell microplate.
Statement Of Problem: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with an edentulous mandible, but information on the effect of the optimum implant position on the peri-implant crestal bone level with immediate loading protocols is lacking.
Purpose: The purpose of this prospective clinical study was to evaluate correlations between different implant positions and crestal bone loss and between interimplant distance and the crestal bone loss in patients with 2IMOs with immediate loading protocols at 1-year follow-up.
Material And Methods: A total of 24 participants (13 men, 11 women, mean ±standard deviation age 63.
Quaternary ammonium silane [(QAS), codename - k21] is a novel biomaterial developed by sol-gel process having broad spectrum antimicrobial activities with low cytotoxicity. It has been used in various concentrations with maximum antimicrobial efficacy and biocompatibility. The antimicrobial mechanism is displayed contact killing, causing conformational changes within the bacterial cell membrane, inhibiting Sortase-A enzyme, and causing cell disturbances due to osmotic changes.
View Article and Find Full Text PDFObjectives: To evaluate the retentive strength of overdenture attachments in 2-implant mandibular overdenture (2IMO) with implants placed at different positions and angulations.
Materials And Methods: Edentulous mandibular models were 3D-printed using CBCT images and Materialise Mimics software and the denture models using the intraoral scanner. Two standard implants were placed parallel at different positions from midline (5, 10, 15, and 20 mm) with 0-0 degree angulations and with different distal angulations (0-5, 0-10, 0-15, 5-5, 10-10, and 15-15 degrees) at 10±mm from midline representing 10 study groups.
Aims: To investigate, using a validated questionnaire, the teaching of removable partial dentures (RPDs) in dental schools of Malaysia.
Materials And Methods: A validated questionnaire to investigating trends in the teaching of RPDs in dental schools in Oceania was emailed (in English version form) to Heads of Restorative/Prosthodontics/course coordinators in the 13 dental schools in Malaysia. Follow-up reminders were sent and participants were given six weeks to complete and return the questionnaire.
Statement Of Problem: The edentulous mandible is commonly treated with a 2-implant overdenture. A change in diameter of the implants may affect the biomechanical behavior of the overdenture, but information on these effects is lacking.
Purpose: The purpose of this 3D finite element analysis study was to evaluate the biomechanical behavior of 2-implant mandibular overdentures (2IMO) and their individual components by using implants of different diameters.
Introduction: The purpose of this review is to compare randomized clinical trials evaluating the patient-reported outcome measures (PROMs) using different unsplinted attachment systems in 2-implant-retained mandibular overdentures (2IRMODs). A focus question (as per PICOS) was set as follows: does one particular unsplinted attachment system (I) compared with another (C) result in better patient-reported outcomes (O) in two-implant-retained mandibular overdentures (P) using randomized controlled trials (S)?
Materials And Methods: A literature search was conducted in the PubMed MEDLINE and Cochrane Central Register of Controlled Trials (CENTRAL) databases between November 2010 and October 2020. Only randomized controlled trials (RCTs) on 2IRMOD using unsplinted attachment systems measuring patient-centered outcomes were selected.
Silane-based/fully hydrolyzed, endodontic irrigant exhibiting antimicrobial properties, is prepared, and is hypothesized to control macrophage polarization for tissue repair. Albino wistar rats were injected with 0.1 ml root canal irrigant, and bone marrow cells procured.
View Article and Find Full Text PDFAim: The purpose of this review is to compare randomized clinical trials evaluating the peri-implant tissue outcomes using different unsplinted attachment systems in two implant-retained mandibular overdentures.
Background: Literature lacks information on various unsplinted attachment systems and their effect on peri-implant tissue health. A focus question (as per PICOS) was set as follows: Does one particular unsplinted attachment system (I) compared with another (C) results in better peri-implant outcomes (O) in two implant-retained mandibular overdentures (P) using randomized controlled trials (RCTs) (S)? The literature search was conducted in the PubMed, MEDLINE and Cochrane Central Register of Controlled Trials (CENTRAL) databases between January 2011 and December 2021.
Statement Of Problem: The 2-implant mandibular overdenture is a popular treatment for the edentulous mandible, but information on optimum implant positions and/or angulations and their stress and strain patterns is lacking.
Purpose: The purpose of this finite element analysis study was to evaluate stress and strain distribution patterns in 2-implant mandibular overdentures with different positions and angulations of implants under unilateral and bilateral loading.
Material And Methods: A cone beam computed tomography (CBCT)-based, 3-dimensional (3D) model of the mandible and an intraoral scanning-based 3D model of the denture were developed in the Mimics software program.
Novel 3D-biomaterial scaffold is constructed having a combination of a new quaternary ammonium silane (k21) antimicrobial impregnated in 3D collagen printed scaffolds cross linked with Riboflavin in presence of d-alpha-tocopheryl poly(ethyleneglycol)-1000-succinate. Groups of "0.1% and 0.
View Article and Find Full Text PDFThis article describes the development and testing of an online asynchronous clinical learning resource named "Ask the Expert" to enhance clinical learning in dentistry. After the resource development, dental students from years 3 and 4 were randomly allocated to two groups (Group A-"Ask the Expert" and L-"lecturer-led"). All the students attempted a pre-test related to replacement of teeth in the anterior aesthetic zone.
View Article and Find Full Text PDFAim: Single implant-retained mandibular overdentures (1IMO) is a viable alternative to 2 implant-retained overdentures (2IMO) in edentulous patients. However, literature lacks in the quality of life (QoL) of these patients when treated with immediate loading protocols. The purpose of this study was to compare oral health-related QoL (OHRQoL) of patients using 1IMO or 2 IMO with immediate loading protocols at 1 month and 1 year.
View Article and Find Full Text PDFThe aim of the study is to investigate a new formulation, based on dioctadecyldimethyl ammonium-bromide (QA) and riboflavin (RF), combining antimicrobial activities and protease inhibitory properties with collagen crosslinking without interference to bonding capabilities in a rabbit model. Quaternary ammonium riboflavin (QARF) experimental adhesives modified with dioctadecyldimethyl ammonium-bromide and riboflavin were bonded (0.5/1.
View Article and Find Full Text PDFTo determine whether quaternary ammonium (k21) binds to Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2) spike protein via computational molecular docking simulations, the crystal structure of the SARS-CoV-2 spike receptor-binding domain complexed with ACE-2 (PDB ID: 6LZG) was downloaded from RCSB PD and prepared using Schrodinger 2019-4. The entry of SARS-CoV-2 inside humans is through lung tissues with a pH of 7.38-7.
View Article and Find Full Text PDFStatement Of Problem: Mini implants (<3 mm in diameter) are being used as an alternative to standard implants for implant-retained mandibular overdentures; however, they may exhibit higher stresses at the crestal level.
Purpose: The purpose of this finite element analysis study was to evaluate the biomechanical behavior (stress distribution pattern) in the mandibular overdenture, mucosa, bone, and implants when retained with 2 standard implants or 2 mini implants under unilateral or bilateral loading conditions.
Material And Methods: A patient with edentulous mandible and his denture was scanned with cone beam computed tomography (CBCT), and a 3D mandibular model was created in the Mimics software program by using the CBCT digital imaging and communications in medicine (DICOM) images.
: The aims of this systematic review were to identify additional infection control measures implemented in dental practice globally to prevent cross-infection and evaluate the psychological impacts of the pandemic among dental professionals. : A sequential systematic literature search was conducted from December 2019 to 30 April 2020 through PubMed, CINAHL, Scopus, Google Scholar, Embase, and Web of Science databases. The search yielded the following results: "COVID-19" ( = 12,137), "Novel corona virus" ( = 63), "COVID-19 and dentistry" ( = 46), "COVID-19 and oral health" ( = 41), "Novel Corona virus and Dentistry" ( = 0), "dental health and Novel Coronavirus" ( = 26), and "dental practice and Novel Coronavirus" ( = 6).
View Article and Find Full Text PDFDuring the current coronavirus disease 2019 (COVID-19) pandemic, dental education and training requiring face-to-face interaction must prioritize infection prevention and the safety of students, staff, and patients. In July 2020, the Association for Dental Education, Asia Pacific (ADEAP) published safety guidelines for safe dental education during the COVID-19 pandemic. These guidelines summarize ADEAP recommendations for classroom-based courses, reopening of simulated training courses and dental clinics, and provision of clinical skills training courses in dentistry during the COIVID-19 pandemic.
View Article and Find Full Text PDFObjective: Here we describe a novel formulation, based on quaternary ammonium (QA) and riboflavin (RF), which combines antimicrobial activities and protease inhibitory properties with collagen crosslinking without interference to bonding capabilities, was investigated.
Methods: Experimental adhesives modified with different fractions of dioctadecyldimethyl ammonium bromide quaternary ammonium and riboflavin (QARF) were formulated. Dentine specimens were bonded to resincomposites with control or the experimental adhesives to be evaluated for bond strength, interfacial morphology, micro-Raman analysis, nano-CT and nano-leakage expression.
Background: There is a continuing concern about how graduate work readiness (WR) reflects on the success of universities meeting the requirements of employment. This study is to establish a valid and reliable instrument measuring WR in health professions (HP) graduates of medicine, pharmacy and dentistry.
Methods: The study from March 2016 to April 2017 was conducted to validate the 'Work Readiness Scale' (WRS; Deakin University) using Principal Component Analysis and Cronbach - α for internal consistency.