Background And Aim: The impact of different anti-thrombotic agents on patients with suspected small bowel bleeding (SSBB) who underwent balloon-assisted enteroscopy (DAE) is unclear. We aimed to examine the clinical effects and predictive factors of DAE based on the thromboembolic agents used.
Methods: We enrolled 399 patients with SSBB from a web-based DAE registry across 30 medical centers in South Korea.
Background: /Aims: Polypectomy is a procedure associated with a high risk of bleeding. Guidelines recommend uninterrupted aspirin use during polypectomy, whereas cessation of clopidogrel 5-7 days before polypectomy is recommended. The cold snare resection technique, with or without submucosal injection, is considered safer than conventional polypectomy using electrocoagulation for post-polypectomy bleeding.
View Article and Find Full Text PDFBackground/aims: Fecal microbiota transplantation (FMT) is a promising therapy for inducing and maintaining remission in patients with ulcerative colitis (UC). However, FMT has not been approved for UC treatment in Korea. Our study aimed to investigate patient perceptions of FMT under the national medical policy.
View Article and Find Full Text PDFBackground/aims: Despite advances in imaging and endoscopic technology, diagnostic modalities for small bowel tumors are simultaneously performed. We investigated the discrepancy rate between each modality and predictive factors of discrepancy in patients with definite small bowel tumors.
Methods: Data of patients with definite small bowel tumors who underwent both device-assisted enteroscopy (DAE) and computed tomography (CT) were retrieved from web-based enteroscopy registry database in Korea.
Background And Aims: The use of conventional oral sulfate tablets (OSTs) has gained popularity; nonetheless, they may be not only inconvenient to swallow but also difficult to dissolve. A novel mini-OST has recently been developed to enhance compliance with conventional OST use. This study aimed to compare the efficacy, tolerability, and safety between mini-OST and conventional OST.
View Article and Find Full Text PDFBackground And Aims: Surgically altered gastrointestinal (GI) tract anatomy hinders deep enteroscopy. While enteroscopy-assisted endoscopic retrograde cholangiopancreatography (ERCP) in patients with altered GI anatomy has been heavily investigated, the role of non-ERCP balloon-assisted enteroscopy (BAE) has yet to be fully elucidated.Please check and confirm the author names and initials are correct.
View Article and Find Full Text PDFColonoscopic polypectomy is effective in decreasing the incidence and mortality of colorectal cancer (CRC). Premalignant polyps discovered during colonoscopy are associated with the risk of metachronous advanced neoplasia. Postpolypectomy surveillance is the most important method for managing advanced metachronous neoplasia.
View Article and Find Full Text PDFThe introduction of device-assisted enteroscopy (DAE) in the beginning of the 21st century has revolutionized the diagnosis and treatment of diseases of the small intestine. In contrast to capsule endoscopy, the other main diagnostic modality of small bowel diseases, DAE has the unique advantages of allowing the observation of the region of interest in detail and enabling tissue acquisition and therapeutic intervention. As DAE becomes an essential procedure in daily clinical practice, there is an increasing need for correct guidelines on when and how it is to be performed and what technical factors should be taken into consideration.
View Article and Find Full Text PDFA training dataset that is limited to a specific endoscope model can overfit artificial intelligence (AI) to its unique image characteristics. The performance of the AI may degrade in images of different endoscope model. The domain adaptation algorithm, i.
View Article and Find Full Text PDFColonoscopic polypectomy is effective in decreasing the incidence and mortality of colorectal cancer (CRC). Premalignant polyps discovered during colonoscopy are associated with the risk of metachronous advanced neoplasia. Postpolypectomy surveillance is the most important method for the management of advanced metachronous neoplasia.
View Article and Find Full Text PDFColonoscopic polypectomy is effective in decreasing the incidence and mortality of colorectal cancer (CRC). Premalignant polyps discovered during colonoscopy are associated with the risk of metachronous advanced neoplasia. Postpolypectomy surveillance is the most important method for managing advanced metachronous neoplasia.
View Article and Find Full Text PDFDevice-assisted enteroscopy (DAE) enables the direct visualization of small bowel lesions with histological diagnosis; however, few studies have described the diagnostic performance of enteroscopic biopsy. We investigated the diagnostic performance of enteroscopic biopsy. We used a nationwide multicenter enteroscopy database to identify patients who underwent DAE with biopsy for small bowel diseases.
View Article and Find Full Text PDFIntroduction: The impact of device-assisted enteroscopy (DAE) on long-term rebleeding in patients with obscure gastrointestinal bleeding (OGIB) exhibiting detectable small-bowel lesions remains unclear. We investigated the long-term rebleeding rate and predictive factors for DAE in patients with OGIB.
Method: Patients with OGIB with small bowel lesions detected through DAE were enrolled at three Korean tertiary hospitals.
Introduction: This systematic review and meta-analysis evaluated the available evidence on the risk of metachronous advanced neoplasia (AN) and colorectal cancer (CRC) in patients with 3-4 nonadvanced adenomas (NAAs).
Methods: We searched MEDLINE, EMBASE, and Cochrane Library databases up to January 2021 for studies evaluating metachronous AN and CRC risk by comparing 3 groups (1-2 vs 3-4 vs ≥5 NAAs) at index colonoscopy. The estimates for risk of metachronous AN and CRC were evaluated using random-effects models.
Background/aims: The adenoma detection rate (ADR) does not reflect the complete detection of every adenoma during colonoscopy; thus, many surrogate indicators have been suggested. This study investigated whether the ADR and surrogate quality indicators reflect the adenoma miss rate (AMR) when performing qualified colonoscopy.
Methods: We performed a prospective, multicenter, cross-sectional study of asymptomatic examinees aged 50 to 75 years who underwent back-to-back screening colonoscopies by eight endoscopists.
Balloon-assisted enteroscopy (BAE) is an important diagnostic modality for ongoing obscure gastrointestinal bleeding (OGIB). However, it is difficult to determine the optimal insertion route. We retrospectively analyzed the records of patients with OGIB contained in a multicenter enteroscopy database of 1108 balloon-assisted enteroscopy (BAE) procedures (875 patients) to find out factors affecting BAE route selection in patients with OGIB.
View Article and Find Full Text PDFThe aim of this study was to assess the appropriate time interval to identify the association between the fecal calprotectin (FC) test and endoscopic activity, and to evaluate whether the time interval affects the therapeutic plan adjustment in patients with ulcerative colitis (UC).This study included 103 patients who underwent FC tests and endoscopic examinations within the past three months. The FC test results classified cases into three groups as follows: moderate to severe (>200, >250, or >300 μg/g), mild (100-200, 100-250, or 100-300 μg/g), and inactive (<100 μg/g) activity.
View Article and Find Full Text PDFBackground: Advances in endoscopic imaging enable the identification of patients at high risk of gastric cancer. However, there are no comparative data on the utility of standard and magnifying narrow-band imaging (M-NBI) endoscopy for diagnosing () infection, gastric atrophy, and intestinal metaplasia.
Aim: To compare the diagnostic performance of standard and M-NBI endoscopy for gastritis and precancerous conditions.
Background: A simple classification for the relevance of lesions (P0, P1, and P2; no bleeding potential, less likely to bleed, and more likely to bleed, respectively) based on capsule endoscopy (CE) findings has been used. This study aimed at investigating rebleeding rates and predictive factors of P0 and P1 lesions after obtaining negative findings in both, CE and computed tomography (CT), for patients with obscure gastrointestinal bleeding (OGIB).
Methods: Among 193 patients resulted in negative CE findings defined as P0 or P1 lesions, 84 patients with negative results on CT images were enrolled in this study.
We report the characteristics of AlN epilayers grown directly on cylindrical-patterned sapphire substrates (CPSS) by hydride vapor-phase epitaxy (HVPE). To evaluate the effect of CPSS, we analyzed the threading dislocation densities (TDDs) of AlN films grown simultaneously on CPSS and flat sapphire substrate (FSS) by transmission electron microscopy (TEM). The corresponding TDD is measured to be 5.
View Article and Find Full Text PDFBackground/aims: Belching disorder (BD) is clinically distinct from gastroesophageal reflux disease (GERD) with belching. Supragastric belching (SGB) is closely associated with reflux episodes. This study investigates belch characteristics in association with reflux, compared between patients with BD and those who had GERD with belching.
View Article and Find Full Text PDF