This in vitro study aimed to investigate the effect of plasma ion implantation nitriding on titanium's surface properties and initial cell response. Grade 4 titanium discs (12.7 × 2 mm) were blasted with aluminum oxide particles to create moderately rough surfaces.
View Article and Find Full Text PDFWetting the dentin is critical to atraumatic restorative treatment. The conventional insertion can be challenging when using high-viscosity glass-ionomer cement. This study evaluated the formation of gaps and voids after three insertion methods using micro-CT.
View Article and Find Full Text PDFMasticatory muscle activity during sleep has been considered independent of variations in the structural characteristics of the dental occlusion. However, scientific evidence contradicting an occlusal causal role is missing. The purpose of this study was to test the null hypothesis that sleep bruxism (SB) is independent of the presence of occlusal interferences.
View Article and Find Full Text PDFContext (background): Resin composites are the most widely used material for restoring cervical defects. However, the high failure rate of these restorations is still a concern.
Aims: The aim of this in vitro study was to evaluate, using microtomography (μCT), the interfacial gap and voids formation in Class V cavities in premolars restored with materials with lower polymerization shrinkage combined with different restorative techniques.
Background: Public hospital managers in Rio de Janeiro must deal with severe budget costs, which is the only source of income of public hospitals. In this sense, systematic supply chain risk management can contribute to identifying such risks, assessing their severity, and developing mitigating plans, or even revealing the lack of such plans. Private hospital networks must also map their risks since they are facing a diminishing of demand given that unemployment in Brazil, which is growing in the past years, generates an impossibility of affording private healthcare.
View Article and Find Full Text PDFThis systematic review addressed the implant success rate after mandible reconstruction with vascularized fibula bone graft. Therefore, preferred reporting items for systematic review and meta-analysis guidelines were used to perform the systematic review, and the search included following databases: PubMed, Lilacs, Google Scholar, Open Gray, Science Direct and Cochrane. A search of medical subject headings (MeSH) and related terms (fibula) OR (vascularized) OR (microvascularized) AND (implant) OR (rehabilitation) OR (osseointegrated) AND (mandible) OR (jaw) OR (maxillofacial), without any language or time restrictions until October 2017 was carried out.
View Article and Find Full Text PDFIntroduction: Functional Cognitive Disorder (FCD) is a non-degenerative, common cause of memory complaint in patients with high educational levels. FCD has been insufficiently described in individuals with low education. Here, we investigated the frequency of FCD among individuals with low education.
View Article and Find Full Text PDFThis study evaluated the cytotoxicity, the antimicrobial and physicochemical properties of root canal sealers incorporated with phytotherapic Uncaria tomentosa (UT). Unmodified AH Plus (Dentsply, DeTrey, Germany) and MTA Fillapex (Angelus, Londrina, Brazil) were used as controls. UT was incorporated into AH Plus and MTA Fillapex, at concentrations of 2% and 5% of the total weight of these sealers (w/w).
View Article and Find Full Text PDFPrimary implant stability is a prerequisite for successful implant osseointegration. The osseodensification technique (OD) is a non-subtractive drilling technique that preserves the bone tissue, increases osteotomy wall density, and improves the primary stability. This study aimed to investigate the hypothesis that OD, through a wider osteotomy, produces healing chambers (HCs) at the implant-bone interface without impacting low-density bone primary stability.
View Article and Find Full Text PDFSilane-coating strategy has been used to bind biological compounds to the titanium surface, thereby making implant devices biologically active. However, it has not been determined if the presence of the silane coating itself is biocompatible to osseointegration. The aim of the present study was to evaluate if silane-coating affects bone formation on titanium using a rabbit model.
View Article and Find Full Text PDFPurpose: The objective of this study was to evaluate the influence of the oxide layer removal procedure using acid on the roughness and internal fit of overcast universal castable long abutments (UCLAs) for a taper connection.
Materials And Methods: For this, maxillary first premolars were waxed on the plastic sleeve of 15 UCLAs with a premachined interface. The specimens were overcast using the NiCr alloy, and the frameworks were randomly distributed to undergo one of two different oxide layer removal methods: blasting with 100-μm particles of aluminum oxide at 0.
Statement Of Problem: Although luting space is related to the marginal fit of indirect restorations, information on its influence on the marginal fit and tensile strength of zirconia abutments bonded to titanium bases is lacking.
Purpose: The purpose of this in vitro study was to evaluate the influence of luting space on the marginal discrepancy and tensile strength of zirconia abutments bonded to a titanium base after dynamic loading.
Material And Methods: Ninety implant replicas were embedded in resin blocks to attach 4-mm-high titanium luting bases.
Background: Recent studies concerning supply chain management have shown that topics such as supply chain risk management (SCRM) and supply chain resilience (SCRes) are the new trends in supply chain management. Initial studies in the early 2000s developed frameworks to identify, measure and mitigate risks and assess/evaluate the degree of resilience of a company or supply chain. Recently, a large variety of studies has emerged, including more conceptual and review studies as well as more sophisticated, quantitative studies.
View Article and Find Full Text PDFInflamm Bowel Dis
January 2021
Clinical uncertainty exists regarding which assay should be designated as the standard monitoring coagulation test for intravenous unfractionated heparin (UFH). Several studies have compared the use of activated partial thromboplastin time (aPTT) and antifactor-Xa (anti-Xa) and have come out with varying results. The correlation between these 2 tests varied, markedly from strong to weak.
View Article and Find Full Text PDFInt J Periodontics Restorative Dent
October 2019
Peri-implant bone remodeling occurs in all osseointegrated implants and can be defined as an adaptive process of bone around the implant in response to functional loading. This retrospective study evaluated the marginal bone remodeling around dental implants with external hexagonal connections in function for more than 10 years. The sample consisted of 17 implants placed in the posterior region of the mandible to replace one or several teeth.
View Article and Find Full Text PDFFamilial hypomagnesemia with hypercalciuria and nephrocalcinosis (FHHNC) is an autosomal recessive tubular disorder caused by mutations in genes that encode renal tight junction proteins claudin-16 or claudin-19, which are responsible for magnesium and calcium paracellular reabsorption in the thick ascending limb of Henle's loop. Progressive renal failure is frequently present, and most of the patients require renal replacement therapy still during adolescence. In this case report, we describe a new homozygous missense mutation on gene (c.
View Article and Find Full Text PDFAim: To investigate the reliability of using bovine teeth as an alternative to human teeth in an intra-tooth push-out model by comparing the bond strength of three root canal sealers in both tooth substrates.
Methodology: From human and bovine incisors (12 per group), one 1-mm disc was obtained from each root. On each disc, three standard 0.
Purpose: To evaluate the fracture resistance after the thermal and mechanical fatigue of feldspathic, lithium disilicate, and resin-modified CAD/CAM monolithic crowns cemented onto a universal post abutment.
Materials And Methods: A right second mandibular molar was designed in CAD/CAM software, and 30 crowns were machined using three different materials (n = 10): feldspathic ceramic, finished only with a glaze cycle (G1); lithium disilicate, sintered and finished with a glaze cycle (G2); and resin, modified by nanoceramic and finished with rubber (G3). All crowns were cemented under a constant 50 N load, the excess cement was removed, and the crowns were light-cured for 30 seconds.
Purpose: The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years.
Materials And Methods: Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP).
Purpose: To evaluate the influence of the collar surface topography on peri-implant marginal bone preservation.
Materials And Methods: A total of 156 patients who received at least one cylindrical implant of regular diameter with an external-hexagon platform in the posterior region of the maxilla or mandible were recalled to the office for a retrospective evaluation. Implantation sites and implant length information were recorded, and implants were divided according to the collar surface topography: machined (M) or rough (R) surface.
Introduction: The present study investigated the root canal dentin bond strength of 2 newly developed fast-setting mineral trioxide aggregate (MTA) and pozzolan-based cements: ENDOCEM MTA (Maruchi, Wonju, Korea) and ENDOCEM Zr (Maruchi). White MTA (Angelus, Londrina, Brazil) was used as the reference material for comparison.
Methods: Root slices (1 mm ± 0.
Purpose: This study evaluated the microleakage at different implant-abutment (I-A) connections under unloaded and loaded conditions.
Materials And Methods: Forty implants, specially designed with an opening at the apex, were grouped according to the I-A and screw device: external hexagon implants with titanium (EH) or EH diamond-like carbon screws fixing the abutment; internal hexagon implants with titanium screws (IH); and Morse taper implants with solid (MT) or MT passing screws (MTps) abutments. The implants were fixed in a 2-compartment device, and toluidine blue solution (1.