Publications by authors named "Semmler V"

Aim: To evaluate whether left bundle branch block with residual conduction (rLBBB) is associated with worse outcomes after cardiac resynchronisation therapy (CRT).

Methods: All consecutive CRT implants at our institution between 2006 and 2013 were identified from our local device registry. Pre- and post-implant patient specific data were extracted from clinical records.

View Article and Find Full Text PDF

Aims: The aim of this retrospective cohort study was to assess the influence of early recurrence (ER) after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) on long-term outcomes and to identify clinical variables associated with ER.

Methods: We retrospectively collected clinical and procedural data from 1285 patients with paroxysmal AF who underwent PVI from 2011 to 2016. Kaplan-Meier, receiver operating characteristic (ROC) curve, logistic and Cox regression analyses were performed to analyze the influence of ER on long-term outcomes.

View Article and Find Full Text PDF

Purpose: This study was designed to evaluate the electromagnetic interference (EMI) effects and safety of the new security screening millimetre wave body scanners (MWBSs) for patients with rare cardiac implantable electronic devices (CIEDs).

Methods: We identified 73 patients with either entirely subcutaneous implantable cardioverter-defibrillators (S-ICD) or leadless pacemakers (LPM) attending routine device follow-up. CIED programming was optimised for the detection of EMI occurrence, and high-voltage therapy was disabled.

View Article and Find Full Text PDF

Therapy of choice for the primary and secondary prevention of sudden cardiac death is the implantation of an implantable cardioverter defibrillator (ICD). Whereas appropriate and inappropriate ICD shocks lead to myocardial microdamage, this is not known for antitachycardia pacing (ATP). In total, 150 ICD recipients (66 ± 12 years, 81.

View Article and Find Full Text PDF

Background: The prevalence of atrial fibrillation (AF) is significantly higher in adults with congenital heart disease (ACHD) compared to patients without congenital heart disease (CHD). As AF in ACHD patients might have significant hemodynamic consequences, rhythm control is particularly desirable but rarely achieved by antiarrhythmic drugs. The aim of this study was to investigate safety and long-term outcome of AF ablation in ACHD patients.

View Article and Find Full Text PDF

Aims: Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF.

View Article and Find Full Text PDF
Article Synopsis
  • Electric cars can create electromagnetic fields that might interfere with some medical devices like heart implants.
  • A study tested 108 patients with these heart devices to see if the cars affected how their devices worked while they were driving or charging.
  • The results showed that the electric cars did not cause any problems with the devices, meaning it’s safe for people with these implants to drive and charge electric cars.
View Article and Find Full Text PDF

Purpose: To determine the current incidence of antitachycardia therapy suspension due to magnet reversion in patients with implantable cardioverter defibrillators (ICDs).

Methods: From March 2012 to September 2018, all St. Jude Medical ICD interrogations performed at the Deutsches Herzzentrum München were screened for stored events of antitachycardia therapy suspension caused by static magnetic fields (flux densities ≥ 1 mT as defined in St.

View Article and Find Full Text PDF

Introduction: Patients with persistent atrial fibrillation (AF) may additionally suffer from a concealed sinus node disease. We sought to determine the incidence, indications and predictors of acute pacemaker [PM] implantation within 1 week after the ablation of persistent AF.

Methods And Results: We performed a retrospective analysis of patients, who had had an ablation of persistent AF at our center.

View Article and Find Full Text PDF

Background: Time has been postulated as an important factor for electrical remodeling of the left atrium (LA) in persistent atrial fibrillation (AF) ('AF begets AF'). However, it is still a matter of debate if structural changes are the cause or consequence of AF. We sought to determine the clinical and invasive parameters, which correlate with LA scar as determined by voltage mapping, in patients with persistent AF.

View Article and Find Full Text PDF

Background: Pulmonary vein (PV) reconduction after PV isolation (PVI) unmasked by adenosine is associated with a higher risk for paroxysmal atrial fibrillation (PAF) recurrence. It is unknown if the reconnected PVs after adenosine testing and immediate re-ablation can predict reconnection and reconnection patterns of PVs at repeat procedures. We assessed reconnection of PVs with and without dormant-conduction (DC) during the first and the repeat procedure.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is a relevant comorbidity in recipients of implantable cardioverter-defibrillators (ICD). Latest generation single-chamber ICD allow the additional sensing of atrial tachyarrhythmias and, therefore, contribute to the early detection and treatment of AF, potentially preventing AF-related stroke. The present study aimed to measure the impact on patient-related costs of this new ICD compared to conventional ICD.

View Article and Find Full Text PDF

Objectives: Thromboembolic complications during atrial fibrillation (AF) ablation due to mobilisation of a pre-existing thrombus formation (TF) in the left atrium (LA) are devastating. The gold standard to exclude LA TF is transesophageal echocardiography (TEE). The present study compares sensitivity and specificity of a dual-source cardiac-computed tomography (DS-CT) with TEE for TF exclusion prior to AF ablation.

View Article and Find Full Text PDF

Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism.

View Article and Find Full Text PDF

Data about the safety of edoxaban in patients who underwent left atrial (LA) radiofrequency (RF) ablation procedures are lacking. This study sought to compare the safety of uninterrupted edoxaban with uninterrupted phenprocoumon administration during LA RF ablation for atrial fibrillation and atrial tachycardia. In total, 231 patients (mean age 64 ± 11years, male 71%) who underwent LA RF ablation under continuous oral anticoagulation (OAC) with edoxaban or phenprocoumon were included in the study.

View Article and Find Full Text PDF

Purpose: In some patients, both an electrophysiological examination (EPS) and a coronary angiography (CA) are necessary. It might be preferable to choose a combined approach of EPS and CA versus performing them consecutively. The purpose of this study is to evaluate the type and rate of adverse events between both approaches.

View Article and Find Full Text PDF

Introduction: For radiofrequency (RF) ablation, the EP Shuttle (Stockert GmbH, Freiburg, Germany), Ampere (St. Jude Medical, St. Paul, MN, USA), and SmartAblate (Biosense Webster, Diamond Bar, CA, USA) generator models are most frequently used in clinical practice.

View Article and Find Full Text PDF

Background: Catheter ablation of right-sided accessory pathways (APs) has lower success and higher recurrence rates compared to left-sided substrates. Irrigated-tip catheter (ITC) ablation might offer an advantage in this setting but data about its use in patients below 18 years are scarce. The aim of this study was to compare an ITC approach to conventional catheter ablation.

View Article and Find Full Text PDF

Background: Remote magnetic navigation (RMN) is attributed to diminish radiation exposure for both patient and operator performing catheter ablation for different arrhythmia substrates. The purpose of this prospective, randomized study was to compare RMN with manually guided catheter ablation for AV nodal reentrant tachycardia (AVNRT) regarding fluoroscopy time/dosage, acute and long-term efficacy as well as safety.

Methods And Results: A total of 218 patients with AVNRT undergoing catheter ablation at three centers (male 34%, mean age 50 ± 17 years) were randomized to a manual approach (n = 113) or RMN (n = 105) using the Niobe magnetic navigation system.

View Article and Find Full Text PDF

Background: Ablation of atrial fibrillation (AF) on uninterrupted phenprocoumon reduces periprocedural thromboembolic and bleeding complications. Heparin is administered intraprocedurally to achieve activated clotting times (ACT) of 300-400 seconds. We investigated the effect of international normalized ratio (INR) on ACT and intraprocedural heparin requirements.

View Article and Find Full Text PDF

The aim of this study was to compare safety and feasibility of a subcutaneous purse-string suture (PSS) with manual compression (MC) to gain hemostasis in patients after multiple femoral venous punctures undergoing electrophysiological procedures on uninterrupted oral anticoagulation (OAK). A total of 784 patients who underwent catheter ablation for atrial fibrillation (n = 564) or (a)typical atrial flutter (n = 220) were assessed. Four hundred sixty-two patients received PSS (58.

View Article and Find Full Text PDF

Background: For persistent atrial fibrillation (AF) ablation, different strategies including complex fractionated atrial electrograms (CFAE) ablation and linear lesions (LL) have been used in addition to pulmonary vein isolation (PVI). However, it is still a matter of debate if extended substrate modification improves long-term outcome. The aim of this study was to determine the benefit of LL in addition to PVI and CFAE ablation regarding freedom from arrhythmia recurrence in patients with persistent AF.

View Article and Find Full Text PDF