Publications by authors named "Semih Buz"

Objectives: The aim of this study was to evaluate the outcomes of transposition of the omentum into the mediastinum to support the replacement of infected aortic grafts or to cover infected aortic grafts that are not amenable for surgical replacement.

Methods: All patients with thoracic aortic graft infections who underwent mediastinal transposition of the omentum at our institution between 2005 and 2023 were included in this study. Mediastinal transposition of the omentum was performed either after replacement of the infected graft ('curative concept') or solely as bailout procedure by wrapping the infected graft ('palliative concept').

View Article and Find Full Text PDF

The treatment of DeBakey type I aortic dissection remains a major challenge in the field of aortic surgery. To upgrade the standard of care hemiarch replacement, a novel device called an "Ascyrus Medical Dissection Stent" (AMDS) is now available. This hybrid device composed of a proximal polytetrafluoroethylene cuff and a distal non-covered nitinol stent is inserted into the aortic arch and the descending thoracic aorta during hypothermic circulatory arrest in addition to hemiarch replacement.

View Article and Find Full Text PDF

Introduction: Open surgical repair remains the current gold standard for the treatment of acute type A aortic dissection. However, especially elderly patients with relevant comorbidities who are deemed unfit for open surgery may benefit from a minimally invasive endovascular approach.

Methods: We report a case of an 80-year-old male with retrograde acute type A aortic dissection and peripheral malperfusion after receiving thoracic endovascular aortic repair due to thoracic aortic aneurysm.

View Article and Find Full Text PDF

Objectives: The aim of this study is to investigate the outcome of elderly patients with surgically treated acute type A aortic dissection (ATAAD) complicated by malperfusion.

Methods: Patients ≥70 years old who underwent surgical treatment for ATAAD between January 2000 and December 2020 were enrolled in this study and stratified by their specific Penn Classification into 4 different subgroups, where Penn Abc was defined as multilevel malperfusion. Short- and long-term outcomes were investigated.

View Article and Find Full Text PDF

Background: Thoracic endovascular aortic repair (TEVAR) is a well-established therapy for descending aortic aneurysms (DTA). There is a paucity of large series reporting the mid- and long-term outcomes from this era. The main aim of this study was to evaluate the outcomes of TEVAR with regards to the effect of aortic morphology and procedure-related variables on survival, reintervention and freedom from endoleaks.

View Article and Find Full Text PDF

Background: Perioperative stroke remains a devastating complication in the operative treatment of acute type A aortic dissection. To reduce the risk of perioperative stroke, different perfusion techniques can be applied. A consensus on the preferred cerebral protection strategy does not exist.

View Article and Find Full Text PDF

Objectives: The goal of this study was to describe the factors affecting mid and late aortic remodelling following thoracic endovascular aortic repair with the PETTICOAT (Provisional Extension To Induce Complete Attachment) technique among patients with complicated acute or subacute type B aortic dissection.

Methods: A retrospective single-centre study that evaluates clinical and morphological outcomes among 65 consecutive patients. The area and diameter of the true and false lumen, overall aortic diameter and false lumen perfusion were evaluated.

View Article and Find Full Text PDF

Seven adult patients underwent a two-stage treatment of complex coarctation (CoA), including surgical revascularization of the left subclavian artery (LSA) to left common carotid artery (LCCA), followed by transcatheter covered stent implantation. The majority of patients (5 of 7, 71%) received 1 covered stent (covered Cheatham Platinum stent: 8 zig/45 mm [ = 2], 10 zig/60 mm [ = 1], 10 zig/65 mm [ = 1]; BeGraft: 24/48 mm [ = 2]). In 1 patient (14%), the implantation of 2 covered stents (BeGraft 20/48 mm) was necessary.

View Article and Find Full Text PDF

Objectives: The present study aims to investigate outcomes after the surgical treatment of acute type A aortic dissection in regard to three available selective cerebral perfusion strategies.

Methods: From 2000 to 2019, patients were selected based on the employment of either retrograde cerebral perfusion (RCP), unilateral antegrade cerebral perfusion (uACP) or bilateral antegrade cerebral perfusion (bACP) during open zone-0 anastomosis. Propensity score TriMatch analysis considering several preoperative and intraoperative variables was used to identify well-balanced triplets.

View Article and Find Full Text PDF

Objectives: The goal of the present study is to investigate changes in supra-aortic vessel perfusion after implantation of the non-covered Ascyrus Medical Dissection Stent (AMDS) for surgical treatment of acute type A aortic dissection.

Methods: From 2017 to 2020, 16 consecutive patients treated with AMDS and involvement (dissection to total occlusion) of at least 1 supra-aortic vessel were included in the study. Centre-line based computed tomography measurements of true, false and total lumen area using Terarecon software were performed before and after surgery.

View Article and Find Full Text PDF

Acute type A aortic dissection (ATAAD) is a life-threatening event that requires immediate surgical treatment. Improvements in surgical treatment, graft technology, organ protection and imaging techniques have led to improved clinical outcomes. Individualized treatment concepts have emerged based on more advanced planning tools that allow for a tailored approach even in complex situations such as multi-level malperfusion.

View Article and Find Full Text PDF

Objectives: Transcatheter mitral valve-in-valve (TMViV) implantation is an alternative treatment to surgery for high-risk patients with degenerated bioprosthetic mitral valves. Some types of bioprostheses are fluoroscopically translucent, resulting in an 'invisible' target deployment area. In this study, we describe the feasibility and outcomes of this procedure using intraoperative fusion of transoesophageal echocardiography (TEE) and live fluoroscopy to facilitate valve deployment in cases of invisible bioprosthetic valves.

View Article and Find Full Text PDF

Introduction: Outflow graft (OG) obstruction is a dangerous complication that may occur for various reasons after the implantation of the left ventricular assist device (LVAD).

Case Report: In this study, we describe the case of a 67-year-old patient on LVAD support who developed a late pseudoaneurysm of the OG anastomosis (to the descending aorta) causing OG stenosis at the level of the anastomosis. The patient was treated with a customized fenestrated endovascular stent graft placed into the descending aorta and stent implantation into the OG.

View Article and Find Full Text PDF

Precise procedural planning is crucial to achieve excellent results in patients undergoing Transcatheter aortic valve implantation (TAVI). The aim of this study was to compare the semi-automated 3mensio (3 m) software to the fully-automated HeartNavigator3 (HN) software. We randomly selected 100 patients from our in-house TAVI-registry and compared aortic annulus and perimeter as well as coronary distances between 3m-measurements and post-hoc HN-measurements.

View Article and Find Full Text PDF

Background: Acute type A aortic dissection (ATAAD) is a surgical emergency with high rates of morbidity and mortality. The treatment of ATAAD is highly individualized and mainly depends on anatomical and technical factors. Great efforts to reduce the time to diagnosis and technological innovations have led to improved surgical results with a lower rate of dissection-related reoperations during long-term follow up.

View Article and Find Full Text PDF
Article Synopsis
  • The study evaluated the clinical success and efficacy of the E-liac Stent Graft System after 12 months, defining success as aneurysm exclusion and proper blood flow in the iliac arteries.
  • The research involved 45 patients across 11 European centers, with a significant majority being male and an average age of 72 years, focusing on both aorto-iliac and isolated iliac treatments.
  • Results indicated a 90% overall clinical success rate, a 100% survival rate, and high primary patency rates of 98% for both the internal and external iliac arteries, highlighting the device's safety and effectiveness, with further long-term data pending.
View Article and Find Full Text PDF

Endovascular treatment is a viable alternative therapy in high-risk patients with acute type A aortic dissection. However, the optimal endovascular treatment strategy is still evolving. Herein, we present a case of a 91-year-old man who successfully underwent repair of an ascending aortic dissection using a stent-in-stent technique.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation has dramatically changed the treatment of valvular heart disease over the past decade. At the same time, the indications for bioprosthesis implantation have been continuously extended toward younger patients, driven by excellent clinical results and improved durability. While the omission of oral anticoagulation reduces the risk of severe bleeding complications, the long-term durability of bioprostheses is still limited.

View Article and Find Full Text PDF

Transcatheter aortic valve replacement (TAVR) in pure aortic regurgitation (AR) is challenging, because of the subsequent difficulty in anchoring the transcatheter valve in a noncalcified device landing zone (DLZ). Prestenting can help to prepare a stable DLZ for TAVR in pure AR and prevent valve migration. Here we report the first-in-human implantation of an uncovered stent into a noncalcified aortic valve as a prestenting strategy to prepare an easy DLZ for TAVR in pure AR.

View Article and Find Full Text PDF

Objectives: To study the safety and feasibility of the E-liac Stent Graft System® in patients with aorto/iliac aneurysms.

Methods: A prospective multicentric European registry of patients receiving the E-liac Stent Graft System® was conducted. Endpoints of the study included the technical success as well as periprocedural events and 30-day endoleaks, reinterventions, internal and external iliac artery patency and mortality.

View Article and Find Full Text PDF

Transcatheter aortic valve implantation shortcomings such as relevant paravalvular leakage (PVL) have been shown to negatively impact survival. The Sapien 3 prosthesis has added features to address these problems. We compared the functional performance of the Sapien 3 (S3) and its predecessor Sapien XT (XT), with a particular focus on PVL.

View Article and Find Full Text PDF

Objective: In this report, we assess the outcome of transcatheter aortic valve implantation (TAVI) in nonagenarians at our institution during a 6-year period.

Methods: Between April 2008 and July 2014, 40 patients with a mean ± SD age of 91.8 ± 2.

View Article and Find Full Text PDF

A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision.

View Article and Find Full Text PDF